User Manual
Page 1
Specifications are trademarks of their respective companies. All product names are subject to change without notice. Ti200, Ti300, Ti400 Thermal Imagers Users Manual PN 4281773 September 2013 © 2013 Fluke Corporation. All rights reserved.
Specifications are trademarks of their respective companies. All product names are subject to change without notice. Ti200, Ti300, Ti400 Thermal Imagers Users Manual PN 4281773 September 2013 © 2013 Fluke Corporation. All rights reserved.
User Manual
Page 4
Ti200, Ti300, Ti400 Users Manual Menus 21 Measurement Menu 21 Range 21 Level/Span 21 Emissivity Adjustment 23 Background (Reflected Background Temperature Compensation 25 Transmission/Transmittance Adjustment 25 Spot Temperatures ...
Ti200, Ti300, Ti400 Users Manual Menus 21 Measurement Menu 21 Range 21 Level/Span 21 Emissivity Adjustment 23 Background (Reflected Background Temperature Compensation 25 Transmission/Transmittance Adjustment 25 Spot Temperatures ...
User Manual
Page 8
... prevent eye damage and personal injury: • Do not look into the laser. Do not point laser directly at www.fluke.com. Ti200, Ti300, Ti400 Users Manual How to Contact Fluke To contact Fluke, call one of the following telephone numbers: • USA: 1-800-760-4523 • Canada: 1-800-36...-FLUKE (1-800-363-5853) • Europe: +31 402-675-200 • Japan: +81-3-6714-3114 • Singapore: +65-6799-5566 •...
... prevent eye damage and personal injury: • Do not look into the laser. Do not point laser directly at www.fluke.com. Ti200, Ti300, Ti400 Users Manual How to Contact Fluke To contact Fluke, call one of the following telephone numbers: • USA: 1-800-760-4523 • Canada: 1-800-36...-FLUKE (1-800-363-5853) • Europe: +31 402-675-200 • Japan: +81-3-6714-3114 • Singapore: +65-6799-5566 •...
User Manual
Page 10
... requirements. Contact your authorized Fluke Service Center for recycling information. 4 Product Category: With reference to Fluke's website for recycling information. See manual. Warning. The affixed label indicates that you must not discard this manual. Go to the equipment ... batteries should be disposed of this product is a list of European Union and European Free Trade Association. Ti200, Ti300, Ti400 Users Manual • See emissivity information for actual temperatures. Battery charging when animated. ...
... requirements. Contact your authorized Fluke Service Center for recycling information. 4 Product Category: With reference to Fluke's website for recycling information. See manual. Warning. The affixed label indicates that you must not discard this manual. Go to the equipment ... batteries should be disposed of this product is a list of European Union and European Free Trade Association. Ti200, Ti300, Ti400 Users Manual • See emissivity information for actual temperatures. Battery charging when animated. ...
User Manual
Page 13
Fluke does not warrant the use ) • Users Manuals in the subject line. 7 Thermal Imagers Before You Start Before You Start Carefully unpack the items in the shipment box: • Thermal Imager • ...or reliability of aftermarket memory cards of different brands or capacities. [2] To request a printed manual of a language not supplied with the Imager or available from Fluke. Specify the product name and language preference in print (English, Spanish, French, German, Chinese)[2] • Users Manuals on CD[2] • SmartView® Software • Warranty Registration Card Note...
Fluke does not warrant the use ) • Users Manuals in the subject line. 7 Thermal Imagers Before You Start Before You Start Carefully unpack the items in the shipment box: • Thermal Imager • ...or reliability of aftermarket memory cards of different brands or capacities. [2] To request a printed manual of a language not supplied with the Imager or available from Fluke. Specify the product name and language preference in print (English, Spanish, French, German, Chinese)[2] • Users Manuals on CD[2] • SmartView® Software • Warranty Registration Card Note...
User Manual
Page 14
... dc output to its maximum capacity. Charge batteries until charge indicators show "full." 4. Put one or two smart batteries into bays of charger base. 3. Ti200, Ti300, Ti400 Users Manual Battery Before you use one of the options that follow: Two-Bay Battery Charger Base 1.
... dc output to its maximum capacity. Charge batteries until charge indicators show "full." 4. Put one or two smart batteries into bays of charger base. 3. Ti200, Ti300, Ti400 Users Manual Battery Before you use one of the options that follow: Two-Bay Battery Charger Base 1.
User Manual
Page 16
... in temporary interruption of the Imager. 3. If this occurs, let the Imager stabilize (cool down or warm up time for two seconds, see Table . Ti200, Ti300, Ti400 Users Manual Optional 12 V Vehicle Charger 1.
... in temporary interruption of the Imager. 3. If this occurs, let the Imager stabilize (cool down or warm up time for two seconds, see Table . Ti200, Ti300, Ti400 Users Manual Optional 12 V Vehicle Charger 1.
User Manual
Page 18
Features and Controls (cont.) Description Hand Strap Manual Focus Control 2-Bay Battery Charging Base AC Power Supply with Mains Adapters 17 16 15 19 18 20 14 Ti200 IR FUSION TECHNOLOGY 21 22 ... Cover Visual Light Camera Lens Laser Pointer/Range Finder Infrared Camera Lens Secondary Trigger Primary Trigger 12 hie06.eps Ti200, Ti300, Ti400 Users Manual Item Table 3.
Features and Controls (cont.) Description Hand Strap Manual Focus Control 2-Bay Battery Charging Base AC Power Supply with Mains Adapters 17 16 15 19 18 20 14 Ti200 IR FUSION TECHNOLOGY 21 22 ... Cover Visual Light Camera Lens Laser Pointer/Range Finder Infrared Camera Lens Secondary Trigger Primary Trigger 12 hie06.eps Ti200, Ti300, Ti400 Users Manual Item Table 3.
User Manual
Page 20
...Buttons Three function buttons and four arrow buttons and ) are easy to recognize, such as a manual override of the buttons and their actions. Table 4 is an overview of the LaserSharp™ Auto Focus... change and go back to the previous menu. to the live Manual Mode, the arrow buttons are always active to use the advanced manual focus as arrows to set the features. Touch targets are the primary controls...options, touch a target on the display with what is displayed. Ti200, Ti300, Ti400 Users Manual Note The user is able to adjust Level and Span.
...Buttons Three function buttons and four arrow buttons and ) are easy to recognize, such as a manual override of the buttons and their actions. Table 4 is an overview of the LaserSharp™ Auto Focus... change and go back to the previous menu. to the live Manual Mode, the arrow buttons are always active to use the advanced manual focus as arrows to set the features. Touch targets are the primary controls...options, touch a target on the display with what is displayed. Ti200, Ti300, Ti400 Users Manual Note The user is able to adjust Level and Span.
User Manual
Page 22
... using the IR-PhotoNotes annotation system: 1. Focus the Imager on the object and pull the primary trigger. 5. Ti200, Ti300, Ti400 Users Manual IR-PhotoNotes™ The IR-PhotoNotes™ photo annotation system allows the user to capture and add up to five visible (digital) images of various objects, text, or other information that is...
... using the IR-PhotoNotes annotation system: 1. Focus the Imager on the object and pull the primary trigger. 5. Ti200, Ti300, Ti400 Users Manual IR-PhotoNotes™ The IR-PhotoNotes™ photo annotation system allows the user to capture and add up to five visible (digital) images of various objects, text, or other information that is...
User Manual
Page 24
... Infrared Image To save or edit. 3. Push to save the image as a data file: 1. Push / to the live view. 18 Ti200, Ti300, Ti400 Users Manual Edit Captured Infrared Image Before saving a file, you can edit or modify the image. With an image in the buffer and you can save an...
... Infrared Image To save or edit. 3. Push to save the image as a data file: 1. Push / to the live view. 18 Ti200, Ti300, Ti400 Users Manual Edit Captured Infrared Image Before saving a file, you can edit or modify the image. With an image in the buffer and you can save an...
User Manual
Page 26
... as painted metal, wood, water, skin, and cloth are good at radiating energy and it is easy to calculate an estimated temperature value. Ti200, Ti300, Ti400 Users Manual Temperature Measurement All objects radiate infrared energy. Many common objects and materials such as they have an emissivity of the object and uses this data...
... as painted metal, wood, water, skin, and cloth are good at radiating energy and it is easy to calculate an estimated temperature value. Ti200, Ti300, Ti400 Users Manual Temperature Measurement All objects radiate infrared energy. Many common objects and materials such as they have an emissivity of the object and uses this data...
User Manual
Page 28
..., push and release to a higher temperature level. 2. While you adjust the manual level, the scale along the right side of the display shows the thermal span as needed. Ti200, Ti300, Ti400 Users Manual Fast Auto/Manual Range Toggle When NOT in the upper right-hand corner of the LCD screen will... indicate the change by saying Auto or Manual. This feature operates the Imager in a semi-automatic mode if...
..., push and release to a higher temperature level. 2. While you adjust the manual level, the scale along the right side of the display shows the thermal span as needed. Ti200, Ti300, Ti400 Users Manual Fast Auto/Manual Range Toggle When NOT in the upper right-hand corner of the LCD screen will... indicate the change by saying Auto or Manual. This feature operates the Imager in a semi-automatic mode if...
User Manual
Page 32
... Do Step 1 again. 3. Note If the Display is set the marker option and go to Measurement > Markers. 2. Push to Measurement > Spot Temp. 2. Ti200, Ti300, Ti400 Users Manual Spot Temperatures The Spot Temperatures are available on the display. Push the / to highlight ON or OFF. 3. Push / to highlight the...
... Do Step 1 again. 3. Note If the Display is set the marker option and go to Measurement > Markers. 2. Push to Measurement > Spot Temp. 2. Ti200, Ti300, Ti400 Users Manual Spot Temperatures The Spot Temperatures are available on the display. Push the / to highlight ON or OFF. 3. Push / to highlight the...
User Manual
Page 34
...-Red Ultra High Contrast High Contrast Ultra Hot Metal Hot Metal Ultra Ironbow Ironbow Ultra Amber Amber Ultra Amber Inverted Amber Inverted Ultra 28 Ti200, Ti300, Ti400 Users Manual Image Menu The Image menu has controls for different features used in .avi format will retain image settings at the time of capture and...
...-Red Ultra High Contrast High Contrast Ultra Hot Metal Hot Metal Ultra Ironbow Ironbow Ultra Amber Amber Ultra Amber Inverted Amber Inverted Ultra 28 Ti200, Ti300, Ti400 Users Manual Image Menu The Image menu has controls for different features used in .avi format will retain image settings at the time of capture and...
User Manual
Page 36
... below the set apparent temperature (or set a low-temperature/dew point color alarm: 1. Push or set apparent temperature alarm level. Ti200, Ti300, Ti400 Users Manual Color Alarms The Imager has various apparent temperature color alarms. The hightemperature color alarm shows a full visible image and only shows infrared information on objects...or set of a set the new value. Set High-Temperature Color Alarm To set these parameters. Push / to Image > Color Alarm. 2. The user must manually determine and set a high-temperature color alarm: 1.
... below the set apparent temperature (or set a low-temperature/dew point color alarm: 1. Push or set apparent temperature alarm level. Ti200, Ti300, Ti400 Users Manual Color Alarms The Imager has various apparent temperature color alarms. The hightemperature color alarm shows a full visible image and only shows infrared information on objects...or set of a set the new value. Set High-Temperature Color Alarm To set these parameters. Push / to Image > Color Alarm. 2. The user must manually determine and set a high-temperature color alarm: 1.
User Manual
Page 38
...on or turn off reflective surfaces. The auto focus system will quickly and accurately focus on the specific area of interest. In addition, the advanced manual focus of the LaserSharp™ Auto Focus System. Point the Imager in the Header zone of the display when you pull the secondary trigger. ...to locate the laser dot on the object. 32 The laser warning symbol () shows in the general direction of the object of interest. Ti200, Ti300, Ti400 Users Manual Camera Menu The Camera menu has controls and options for the LaserSharp Auto Focus System. Release the trigger.
...on or turn off reflective surfaces. The auto focus system will quickly and accurately focus on the specific area of interest. In addition, the advanced manual focus of the LaserSharp™ Auto Focus System. Point the Imager in the Header zone of the display when you pull the secondary trigger. ...to locate the laser dot on the object. 32 The laser warning symbol () shows in the general direction of the object of interest. Ti200, Ti300, Ti400 Users Manual Camera Menu The Camera menu has controls and options for the LaserSharp Auto Focus System. Release the trigger.