User Manual
Page 1
All product names are subject to change without notice. All rights reserved. Ti100, Ti105, Ti110, Ti125, TiR105, TiR110, TiR125 Thermal Imagers Users Manual PN 3889825 February 2012, Rev.1, 2/13 © 2012-2013 Fluke Corporation. Specifications are trademarks of their respective companies.
All product names are subject to change without notice. All rights reserved. Ti100, Ti105, Ti110, Ti125, TiR105, TiR110, TiR125 Thermal Imagers Users Manual PN 3889825 February 2012, Rev.1, 2/13 © 2012-2013 Fluke Corporation. Specifications are trademarks of their respective companies.
User Manual
Page 7
... via the SD memory card or by a direct USB connection to an SD memory card. The Imager includes SmartView® software. Introduction The Fluke Ti100, Ti105, Ti110, Ti125, TiR105, TiR110, and TiR125 Thermal Imagers (the Product or Imager) are handheld, infrared imaging cameras for use the IR-OptiFlex™ focus system. The Ti105, Ti110 and Ti125 are...
... via the SD memory card or by a direct USB connection to an SD memory card. The Imager includes SmartView® software. Introduction The Fluke Ti100, Ti105, Ti110, Ti125, TiR105, TiR110, and TiR125 Thermal Imagers (the Product or Imager) are handheld, infrared imaging cameras for use the IR-OptiFlex™ focus system. The Ti105, Ti110 and Ti125 are...
User Manual
Page 9
... Product if it operates incorrectly. • Do not use and disable the Product if it is damaged. 3 FCC ID: T68-F125 IC: 6627A-F125 Figure 1. Thermal Imagers Radio Frequency Data US PAT.
... Product if it operates incorrectly. • Do not use and disable the Product if it is damaged. 3 FCC ID: T68-F125 IC: 6627A-F125 Figure 1. Thermal Imagers Radio Frequency Data US PAT.
User Manual
Page 11
... your authorized Fluke Service Center for recycling information. 5 Conforms to requirements of symbols used on the Imager and in the WEEE Directive Annex I, this product is a list of European Union and European Free Trade Association. Thermal Imagers Accessories Table... 1 is classed as unsorted municipal waste. Battery charging when animated. Battery removed. Audio recording associated with the displayed image. See manual. Warning. Table 1. Conforms...
... your authorized Fluke Service Center for recycling information. 5 Conforms to requirements of symbols used on the Imager and in the WEEE Directive Annex I, this product is a list of European Union and European Free Trade Association. Thermal Imagers Accessories Table... 1 is classed as unsorted municipal waste. Battery charging when animated. Battery removed. Audio recording associated with the displayed image. See manual. Warning. Table 1. Conforms...
User Manual
Page 13
... You Start Ti100 Ti105 Ti110 Ti125 TiR105 TiR110 TiR125 Item Thermal Imager AC Power Adapter Two-Bay Battery Charge Base • • Lithium-ion Smart Battery Hard Carrying Case USB Cable SD Memory Card[1] Multi-format...of aftermarket SD memory cards of different brands or capacities. [2] To request a printed manual of a language not supplied with the Imager. Specify the product name and language preference in Table 3. Table 3. Fluke does not warrant the use ) Users Manuals in print (English, Spanish, French, German, Chinese)[2] Users Manuals on CD[2] ...
... You Start Ti100 Ti105 Ti110 Ti125 TiR105 TiR110 TiR125 Item Thermal Imager AC Power Adapter Two-Bay Battery Charge Base • • Lithium-ion Smart Battery Hard Carrying Case USB Cable SD Memory Card[1] Multi-format...of aftermarket SD memory cards of different brands or capacities. [2] To request a printed manual of a language not supplied with the Imager. Specify the product name and language preference in Table 3. Table 3. Fluke does not warrant the use ) Users Manuals in print (English, Spanish, French, German, Chinese)[2] Users Manuals on CD[2] ...
User Manual
Page 15
...the LCD for the most accurate temperature measurement is fully charged. Caution To prevent damage to the Imager, remove it is disabled automatically. Thermal Imagers Before You Start Keep the Imager attached to the charger until the indicator shows full on the screen. 4. Connect the output to your ... of 10 minutes if the most accurate temperature measurements and best image quality. Note All thermal imagers need sufficient warm-up in video mode, the Sleep Mode/Auto Off feature is always best to restart the Imager. Note When the battery is connected to ac power, or ...
...the LCD for the most accurate temperature measurement is fully charged. Caution To prevent damage to the Imager, remove it is disabled automatically. Thermal Imagers Before You Start Keep the Imager attached to the charger until the indicator shows full on the screen. 4. Connect the output to your ... of 10 minutes if the most accurate temperature measurements and best image quality. Note All thermal imagers need sufficient warm-up in video mode, the Sleep Mode/Auto Off feature is always best to restart the Imager. Note When the battery is connected to ac power, or ...
User Manual
Page 17
...-free mode, but also have the flexibility for Ti100, Ti105, TiR105) Lithium-ion Smart Battery 2-Bay Battery Charging Base AC Power Adapter with Mains Adapters Focus Models Ti110, Ti125, TiR110, and TiR125 have IR-OptiFlex focus. Item Thermal Imagers Focus Table 4. Features and Controls (cont.) Description AC Adapter/Charger... Trigger Primary Trigger Hand Strap Anchor Post (Right and Left) IR-OptiFlex™ Focus Control (not applicable for close focus situations ( The Ti100, Ti105, and TiR105 use a large depth of field focus-free system.
...-free mode, but also have the flexibility for Ti100, Ti105, TiR105) Lithium-ion Smart Battery 2-Bay Battery Charging Base AC Power Adapter with Mains Adapters Focus Models Ti110, Ti125, TiR110, and TiR125 have IR-OptiFlex focus. Item Thermal Imagers Focus Table 4. Features and Controls (cont.) Description AC Adapter/Charger... Trigger Primary Trigger Hand Strap Anchor Post (Right and Left) IR-OptiFlex™ Focus Control (not applicable for close focus situations ( The Ti100, Ti105, and TiR105 use a large depth of field focus-free system.
User Manual
Page 18
... proper alignment. >4 ft 4 ft Figure 2. You will see a live thermal image on the display as it shows a sharper image. When the target moves out of the Imager. When your target comes into focus, it changes. In this position. See Figure 2. Ti100, Ti105, Ti110, Ti125, TiR105, TiR110, TiR125 Users Manual To operate the IR-OptiFlex focus...
... proper alignment. >4 ft 4 ft Figure 2. You will see a live thermal image on the display as it shows a sharper image. When the target moves out of the Imager. When your target comes into focus, it changes. In this position. See Figure 2. Ti100, Ti105, Ti110, Ti125, TiR105, TiR110, TiR125 Users Manual To operate the IR-OptiFlex focus...
User Manual
Page 19
...for a pistol-grip device. How to enable the laser and torch, see pages 36 and 37. The secondary trigger operates the laser and torch. Table 5. Thermal Imagers Primary and Secondary Triggers Primary and Secondary Triggers The two-part trigger is located in the standard trigger position for video recording. In normal operation... trigger. In live Manual Mode, the arrow buttons are the primary controls. The larger, green trigger is the secondary trigger. Table 5 is to capture a thermal image for possible storage to highlight an option Fast forward/rewind (video mode only) 13
...for a pistol-grip device. How to enable the laser and torch, see pages 36 and 37. The secondary trigger operates the laser and torch. Table 5. Thermal Imagers Primary and Secondary Triggers Primary and Secondary Triggers The two-part trigger is located in the standard trigger position for video recording. In normal operation... trigger. In live Manual Mode, the arrow buttons are the primary controls. The larger, green trigger is the secondary trigger. Table 5 is to capture a thermal image for possible storage to highlight an option Fast forward/rewind (video mode only) 13
User Manual
Page 20
... primary trigger. To change the file format, see File Format on the selected file format settings, the Imager shows the captured image and a menu bar. Ti100, Ti105, Ti110, Ti125, TiR105, TiR110, TiR125 Users Manual How to that the object is in focus. The primary menu shows five ... The menus, coupled with the three function buttons and arrow buttons, are the access for thermal image display, camera features, memory review, and settings for Measurement, Image, Camera, Memory, and Settings. To cancel the captured image, pull the primary trigger again or to return to the Live view...
... primary trigger. To change the file format, see File Format on the selected file format settings, the Imager shows the captured image and a menu bar. Ti100, Ti105, Ti110, Ti125, TiR105, TiR110, TiR125 Users Manual How to that the object is in focus. The primary menu shows five ... The menus, coupled with the three function buttons and arrow buttons, are the access for thermal image display, camera features, memory review, and settings for Measurement, Image, Camera, Memory, and Settings. To cancel the captured image, pull the primary trigger again or to return to the Live view...
User Manual
Page 21
...61522;/ to enter the Picture mode. 4. Voice Records To add a voice (audio) record: 1. With an image in the buffer, push to open the EDIT IMAGE menu. 2. Examples of an annotation include motor name plates, printed information or warning signs, larger views of audio. Up...visible image that is stored with the infrared image as part of an infrared image. With an image in the buffer, push to open the EDIT IMAGE menu. 2. Focus Imager on the object and pull the primary trigger. 5. The display updates to show the recorded time. 4. Thermal Imagers Image Capture ...
...61522;/ to enter the Picture mode. 4. Voice Records To add a voice (audio) record: 1. With an image in the buffer, push to open the EDIT IMAGE menu. 2. Examples of an annotation include motor name plates, printed information or warning signs, larger views of audio. Up...visible image that is stored with the infrared image as part of an infrared image. With an image in the buffer, push to open the EDIT IMAGE menu. 2. Focus Imager on the object and pull the primary trigger. 5. The display updates to show the recorded time. 4. Thermal Imagers Image Capture ...
User Manual
Page 23
... the SD memory card, make sure that the write-protect lock is open. Figure 3. The card should pop partially out after you release it catches. Thermal Imagers SD Memory Card SD Memory Card To eject an SD memory card, push in until it . Carefully push the card into the slot with the...
... the SD memory card, make sure that the write-protect lock is open. Figure 3. The card should pop partially out after you release it catches. Thermal Imagers SD Memory Card SD Memory Card To eject an SD memory card, push in until it . Carefully push the card into the slot with the...
User Manual
Page 25
... to set the change and go back to the live view. 19 Thermal Imagers Menus Menus The menus, together with the three function buttons and arrow buttons, are access for thermal image display, camera features, memory setup, and settings for the calculation and display of... to view the menu. 4. Measurement Menu The Measurement Menu has settings for date, time, language, units, file format, and Imager information. Push / to the thermal images. Push or to the live view. • or to set for manual adjustment. Push ...
... to set the change and go back to the live view. 19 Thermal Imagers Menus Menus The menus, together with the three function buttons and arrow buttons, are access for thermal image display, camera features, memory setup, and settings for the calculation and display of... to view the menu. 4. Measurement Menu The Measurement Menu has settings for date, time, language, units, file format, and Imager information. Push / to the thermal images. Push or to the live view. • or to set for manual adjustment. Push ...
User Manual
Page 27
See Figure 4. Level Thermal Imagers Menus Total Imager Range Span Figure 4. Level and Span Settings gju02.eps Temperature Span for Manual Operation Mode When in manual mode, the span setting contracts or expands ... to increase or widen the temperature span. 2. While you adjust the manual span, the scale along the right side of the display shows the thermal span increasing or decreasing in a temperature range within the total range. In the live manual mode, the arrow buttons are always available to adjust the...
See Figure 4. Level Thermal Imagers Menus Total Imager Range Span Figure 4. Level and Span Settings gju02.eps Temperature Span for Manual Operation Mode When in manual mode, the span setting contracts or expands ... to increase or widen the temperature span. 2. While you adjust the manual span, the scale along the right side of the display shows the thermal span increasing or decreasing in a temperature range within the total range. In the live manual mode, the arrow buttons are always available to adjust the...
User Manual
Page 29
Push . 2. Push / to highlight Measurement. 3. Very hot objects or very cold objects can make the temperature measurement better in the Background tab. Thermal Imagers Menus 8. Push / to change and go back to the live view. • or to set the change and go back to ...
Push . 2. Push / to highlight Measurement. 3. Very hot objects or very cold objects can make the temperature measurement better in the Background tab. Thermal Imagers Menus 8. Push / to change and go back to the live view. • or to set the change and go back to ...
User Manual
Page 31
...set to Display All, you see the information about current transmission correction as τ = xx. Push or to highlight Measurement. 3. Thermal Imagers Menus 7. Push / to view the menu. 4. Push / to view the menu. 6. Note If the Display is set to ...61525; to set the change and go back to the live view. Push . 2. To turn on the display as the temperature measurements of the image fluctuate. Push / to the live view. • or to set the change and go back to the previous ...
...set to Display All, you see the information about current transmission correction as τ = xx. Push or to highlight Measurement. 3. Thermal Imagers Menus 7. Push / to view the menu. 4. Push / to view the menu. 6. Note If the Display is set to ...61525; to set the change and go back to the live view. Push . 2. To turn on the display as the temperature measurements of the image fluctuate. Push / to the live view. • or to set the change and go back to the previous ...
User Manual
Page 33
... or to increase the size of the Center Box. 4. Push to view the menu. 4. Push to highlight Measurement. 3. Thermal Imagers Menus Center Box The Center Box feature is an adjustable temperature measurement zone (box) that area. The level and span of the Center Box, push...menu. • to cancel the change and go back to the live view. 27 When satisfied with the size of the Imager is on the infrared image. Push / to reduce the size of the Center Box when enabled: 1. Push or to highlight Center...
... or to increase the size of the Center Box. 4. Push to view the menu. 4. Push to highlight Measurement. 3. Thermal Imagers Menus Center Box The Center Box feature is an adjustable temperature measurement zone (box) that area. The level and span of the Center Box, push...menu. • to cancel the change and go back to the live view. 27 When satisfied with the size of the Imager is on the infrared image. Push / to reduce the size of the Center Box when enabled: 1. Push or to highlight Center...
User Manual
Page 35
... select a palette. 29 Push / to highlight Standard or Ultra Contrast. 9. Push or to highlight Image. 5. Thermal Imagers Menus Table 6. Push / to view the menu. 8. Palettes Ti100 Ti105 Ti110 Ti125 TiR105 TiR110 TiR125 Standard Palettes Grayscale • • Grayscale Inverted • • • • Blue-Red • • High...
... select a palette. 29 Push / to highlight Standard or Ultra Contrast. 9. Push or to highlight Image. 5. Thermal Imagers Menus Table 6. Push / to view the menu. 8. Palettes Ti100 Ti105 Ti110 Ti125 TiR105 TiR110 TiR125 Standard Palettes Grayscale • • Grayscale Inverted • • • • Blue-Red • • High...
User Manual
Page 37
... a dew point color alarm, manual determination and input of a set these parameters. Push / to highlight the option: Set High Alarm. 2. Thermal Imagers Menus 8. Push / to view the menu. Push . 2. Push or to highlight an option. 9. Push: •...; to set the change and go back to the live view. Color Alarm The Imager has various apparent temperature color alarms (not applicable for Ti100, Ti105, TiR105). Depending on objects or areas that are above the set apparent temperature/dew point color alarm level. ...
... a dew point color alarm, manual determination and input of a set these parameters. Push / to highlight the option: Set High Alarm. 2. Thermal Imagers Menus 8. Push / to view the menu. Push . 2. Push or to highlight an option. 9. Push: •...; to set the change and go back to the live view. Color Alarm The Imager has various apparent temperature color alarms (not applicable for Ti100, Ti105, TiR105). Depending on objects or areas that are above the set apparent temperature/dew point color alarm level. ...
User Manual
Page 39
... has on the display. Push / to highlight Compass. 33 Push / to highlight Camera. 3. Compass The Imager (not applicable for Ti100, Ti105, TiR105) includes an eight-point cardinal compass on and off functions. Push / to the live view. This compass lets you ... Camera menu has controls and options for secondary camera features such as Compass, Video, Laser Pointer, Torch, and Backlight level. Thermal Imagers Menus Display Graphics Presentation The options for how you accurately record the target locations for analysis and reports.
... has on the display. Push / to highlight Compass. 33 Push / to highlight Camera. 3. Compass The Imager (not applicable for Ti100, Ti105, TiR105) includes an eight-point cardinal compass on and off functions. Push / to the live view. This compass lets you ... Camera menu has controls and options for secondary camera features such as Compass, Video, Laser Pointer, Torch, and Backlight level. Thermal Imagers Menus Display Graphics Presentation The options for how you accurately record the target locations for analysis and reports.