GIGABYTE GS-R22T61-RH/GS-R22T81-RH 2U Rack Mount Server Service Guide Dual Intel® Xeon LGA1366 Processor Serverboard Rev. 1.0
GIGABYTE GS-R22T61-RH/GS-R22T81-RH 2U Rack Mount Server Service Guide Dual Intel® Xeon LGA1366 Processor Serverboard Rev. 1.0
Manual
Page 3
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server Table of Contents Preface...2 Safety, Care and Regulatory Information 5 System Specification 9 System Hardware Installation 11 Chassis Removal and Installation 12 CPU Installation ...13 Heat Sink ...
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server Table of Contents Preface...2 Safety, Care and Regulatory Information 5 System Specification 9 System Hardware Installation 11 Chassis Removal and Installation 12 CPU Installation ...13 Heat Sink ...
Manual
Page 4
Table of Content BIOS Setup 46 Main ...48 Advanced 50 Processor Configuration 51 Processor Power Management 55 Memory Configuration ...58 Advanced Chipset Configuration 60 PCI Configuration ...64 SATA Configuration ...66 I/O DeviceConfiguration 69 Boot Configuration ...71 Thermal and Acoustic Configuration 73 Power ...75 Security ...77 Server ...79 System Management ...80 Console Redirection ...82 Event Log Configuration 84 Boot ...85 Exit ...86 Appexdix A Phoenix BIOS Beep Codes 92 Appexdix B PhoenixBIOS POST Error Messages List 96 4
Table of Content BIOS Setup 46 Main ...48 Advanced 50 Processor Configuration 51 Processor Power Management 55 Memory Configuration ...58 Advanced Chipset Configuration 60 PCI Configuration ...64 SATA Configuration ...66 I/O DeviceConfiguration 69 Boot Configuration ...71 Thermal and Acoustic Configuration 73 Power ...75 Security ...77 Server ...79 System Management ...80 Console Redirection ...82 Event Log Configuration 84 Boot ...85 Exit ...86 Appexdix A Phoenix BIOS Beep Codes 92 Appexdix B PhoenixBIOS POST Error Messages List 96 4
Manual
Page 5
... provided for Product with Modems, Telecommunications, ot Local Area Network Options Observe the following guidelines when working with local and national electrical codes. GS-R22T61-RH/GS-R22T81-RH Rack Mount Server Safety, Care and Regulatory Information Important safety information Read and follow all instructions marked on the product and in the documentation...
... provided for Product with Modems, Telecommunications, ot Local Area Network Options Observe the following guidelines when working with local and national electrical codes. GS-R22T61-RH/GS-R22T81-RH Rack Mount Server Safety, Care and Regulatory Information Important safety information Read and follow all instructions marked on the product and in the documentation...
Manual
Page 7
... user to this equipment, or equipment malfunctions, may be connected to the facilities of a FAX transmission be connected to disconnect the equipment. GS-R22T61-RH/GS-R22T81-RH Rack Mount Server the FCC. Your telephone company may make such connections themselves, but should not attempt to maintain uninterrupted telephone service. The Department does not...
... user to this equipment, or equipment malfunctions, may be connected to the facilities of a FAX transmission be connected to disconnect the equipment. GS-R22T61-RH/GS-R22T81-RH Rack Mount Server the FCC. Your telephone company may make such connections themselves, but should not attempt to maintain uninterrupted telephone service. The Department does not...
Manual
Page 9
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server System Specification Motherboard Processor Supported Chipset System Memory: Memory Capacity Memory Type DIMM Size Error Correction: ...
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server System Specification Motherboard Processor Supported Chipset System Memory: Memory Capacity Memory Type DIMM Size Error Correction: ...
Manual
Page 10
... Integrated LANs: Controller Intel® 82576EB controller support dual GbE ports Integrated Graphics: Controller Integrated in Server Engines Pilot II Graphics Memory 32MB DDR2 Mass Storage System 6 x 3.5" Hot-Swap SATA /SAS ...System BIOS: BIOS Type Phoenix BIOS on 8Mb flash ROM Server Management Functions: (Optional device) BMC Chip Server Engines POLIT 2 IPMI 2.0 controller Failure Detection IPMI 2.0 specification of Server management Event Logging 32KB Nonvolatile Memory to Log System Failure Events...
... Integrated LANs: Controller Intel® 82576EB controller support dual GbE ports Integrated Graphics: Controller Integrated in Server Engines Pilot II Graphics Memory 32MB DDR2 Mass Storage System 6 x 3.5" Hot-Swap SATA /SAS ...System BIOS: BIOS Type Phoenix BIOS on 8Mb flash ROM Server Management Functions: (Optional device) BMC Chip Server Engines POLIT 2 IPMI 2.0 controller Failure Detection IPMI 2.0 specification of Server management Event Logging 32KB Nonvolatile Memory to Log System Failure Events...
Manual
Page 11
.... 1. Open the system according to it. 3. Unplug all telecommunication cables from the power outlets. 4. Warning! GS-R22T61-RH/GS-R22T81-RH Rack Mount Server System Hardware Installation Pre-installation Instructions Perform the steps below before you open the server or before you remove or replace any hardware configuration. 2. Place the system unit on a flat and...
.... 1. Open the system according to it. 3. Unplug all telecommunication cables from the power outlets. 4. Warning! GS-R22T61-RH/GS-R22T81-RH Rack Mount Server System Hardware Installation Pre-installation Instructions Perform the steps below before you open the server or before you remove or replace any hardware configuration. 2. Place the system unit on a flat and...
Manual
Page 13
Step 2 The CPU only fits in one orientation. Step 3 Push the metal lever back into locked position. 1 2 3 13 GS-R22T61-RH/GS-R22T81-RH Rack Mount Server CPU Installation Please make sure the CPU type and speed that are supported by the motherboard. Step 1 Raise the metal locking lever on the socket. Insert the CPU with the correct orientation.
Step 2 The CPU only fits in one orientation. Step 3 Push the metal lever back into locked position. 1 2 3 13 GS-R22T61-RH/GS-R22T81-RH Rack Mount Server CPU Installation Please make sure the CPU type and speed that are supported by the motherboard. Step 1 Raise the metal locking lever on the socket. Insert the CPU with the correct orientation.
Manual
Page 15
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server Memory Installation Step 1. NOTE! Reverse the installation steps when you wish to lock the DIMM module. Insert the DIMM memory module vertically into the DIMM slot, and push it down. Step 2. For dualquad channel operation, DIMMs must be installed in order starting from DIMMA1/D1 sockets. DIMM must be populated in matched pairs. Close the plastic clip at both edges of the DIMM slots to remove the DIMM module. 2 1 2 DIMMF1 DIMME1 DIMMF2 DIMME2 DIMMD1 DIMMD2 CPU2 CPU1 DIMMA2 DIMMA1 DIMMB2 DIMMB1 DIMMC2 DIMMC1 15 Step 3.
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server Memory Installation Step 1. NOTE! Reverse the installation steps when you wish to lock the DIMM module. Insert the DIMM memory module vertically into the DIMM slot, and push it down. Step 2. For dualquad channel operation, DIMMs must be installed in order starting from DIMMA1/D1 sockets. DIMM must be populated in matched pairs. Close the plastic clip at both edges of the DIMM slots to remove the DIMM module. 2 1 2 DIMMF1 DIMME1 DIMMF2 DIMME2 DIMMD1 DIMMD2 CPU2 CPU1 DIMMA2 DIMMA1 DIMMB2 DIMMB1 DIMMC2 DIMMC1 15 Step 3.
Manual
Page 17
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server R-DIMM Population Table Interleave Channel A Channel B Channel C mode DIMMA1/D1 DIMMA2/D2 DIMMB1/E1 DIMMB2/E2 DIMMC1/F1 DIMMC2/F2 Total Memory Single Channel 1GB 2GB 4GB 1GB 2GB 4GB 8GB 1GB 2GB 4GB 1GB 2GB 4GB 8GB 2GB 4GB 8GB Dual Channel Three Channel 8GB 1GB 2GB 4GB 8GB 1GB 2GB 4GB 8GB 1GB 2GB 4GB 8GB 1GB 2GB 4GB 8GB 1GB 2GB 4GB 8GB 8GB 1GB 2GB 4GB 8GB 1GB 2GB 4GB 8GB 1GB 2GB 4GB 8GB 1GB 2GB 4GB 8GB 1GB 2GB 4GB 8GB 1GB 2GB 4GB 8GB 1GB 2GB 4GB 8GB 1GB 2GB 4GB 8GB 16GB 4GB 8GB 16GB 32GB 3GB 6GB 12GB 24GB 6GB 12GB 24GB 48GB 17
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server R-DIMM Population Table Interleave Channel A Channel B Channel C mode DIMMA1/D1 DIMMA2/D2 DIMMB1/E1 DIMMB2/E2 DIMMC1/F1 DIMMC2/F2 Total Memory Single Channel 1GB 2GB 4GB 1GB 2GB 4GB 8GB 1GB 2GB 4GB 1GB 2GB 4GB 8GB 2GB 4GB 8GB Dual Channel Three Channel 8GB 1GB 2GB 4GB 8GB 1GB 2GB 4GB 8GB 1GB 2GB 4GB 8GB 1GB 2GB 4GB 8GB 1GB 2GB 4GB 8GB 8GB 1GB 2GB 4GB 8GB 1GB 2GB 4GB 8GB 1GB 2GB 4GB 8GB 1GB 2GB 4GB 8GB 1GB 2GB 4GB 8GB 1GB 2GB 4GB 8GB 1GB 2GB 4GB 8GB 1GB 2GB 4GB 8GB 16GB 4GB 8GB 16GB 32GB 3GB 6GB 12GB 24GB 6GB 12GB 24GB 48GB 17
Manual
Page 18
Step 5 Slide another expansion card into the slot until the card firmly seats. Step 3 Lift the riser bracket slightly, then pull it out from the server chassis. Step 4 Slide the expansion card into the slot until the card firmly seats. Hardware Installation Process PCI Expansion Card Installation (GC-RLE2N-RH/GC-RFE2N-RH) Step 1 Loosen the riser bracket screws which attached on on the system. Step 2 Loosen the rest riser bracket bracket screws. Align the riser bracket to the system module. 2 21 2 1 3 18
Step 5 Slide another expansion card into the slot until the card firmly seats. Step 3 Lift the riser bracket slightly, then pull it out from the server chassis. Step 4 Slide the expansion card into the slot until the card firmly seats. Hardware Installation Process PCI Expansion Card Installation (GC-RLE2N-RH/GC-RFE2N-RH) Step 1 Loosen the riser bracket screws which attached on on the system. Step 2 Loosen the rest riser bracket bracket screws. Align the riser bracket to the system module. 2 21 2 1 3 18
Manual
Page 20
Attach anothr PCI-E card to the riser bracket. Attach the PCI-E card to the riser bracket the other side. Align the riser bracket to the system module until it out from the server chassis. Secure the card with screws. Secure the card with screws. Loosen the rest riser bracket bracket screws. Hardware Installation Process PCI Expansion Card Installation (GC-RFX2N-RH/Optional) Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 Step 7 Step 8 Loosen the riser bracket screws which attached on on the system. Lift the riser bracket slightly, then pull it firmly seats. 2 21 2 1 3 20
Attach anothr PCI-E card to the riser bracket. Attach the PCI-E card to the riser bracket the other side. Align the riser bracket to the system module until it out from the server chassis. Secure the card with screws. Secure the card with screws. Loosen the rest riser bracket bracket screws. Hardware Installation Process PCI Expansion Card Installation (GC-RFX2N-RH/Optional) Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 Step 7 Step 8 Loosen the riser bracket screws which attached on on the system. Lift the riser bracket slightly, then pull it firmly seats. 2 21 2 1 3 20
Manual
Page 23
Connect cable and power. 2 1 4 3 4 23 GS-R22T61-RH/GS-R22T81-RH Rack Mount Server GS-R22T61-RH Hard Disk Drive Installation Step 1 Step 2 Step 3 Step 4 Press the release button. Pull the blank out of the drive bay. Slide the blank into the bay until it with screws. Secure it locks into blank. Place hard disk into place.
Connect cable and power. 2 1 4 3 4 23 GS-R22T61-RH/GS-R22T81-RH Rack Mount Server GS-R22T61-RH Hard Disk Drive Installation Step 1 Step 2 Step 3 Step 4 Press the release button. Pull the blank out of the drive bay. Slide the blank into the bay until it with screws. Secure it locks into blank. Place hard disk into place.
Manual
Page 25
Number indicates the HDD installation order. 25 GS-R22T61-RH/GS-R22T81-RH Rack Mount Server Appearance of GS-R22T61-RH/GS-R22T81-RH Front View of GS-R22T61-RH (For 3.5 HDDs solution) 2 5 1 4 0 3 Front panel LEDs and Power Button USB connectors VGA port 3.5" Hot-Swap SATA/SAS HDDs Front View of GS-R22T81-RH (For 2.5 HDDs solution) 0 1 2 3 4 5 6 7 8 9 10 11 12 1314 15 Front panel LEDs and Power Button USB connectors VGA port 2.5" Hot-Swap SATA/SAS HDDs NOTE! For Front LED description, please go to Switch and LED Indicators Introduction section.
Number indicates the HDD installation order. 25 GS-R22T61-RH/GS-R22T81-RH Rack Mount Server Appearance of GS-R22T61-RH/GS-R22T81-RH Front View of GS-R22T61-RH (For 3.5 HDDs solution) 2 5 1 4 0 3 Front panel LEDs and Power Button USB connectors VGA port 3.5" Hot-Swap SATA/SAS HDDs Front View of GS-R22T81-RH (For 2.5 HDDs solution) 0 1 2 3 4 5 6 7 8 9 10 11 12 1314 15 Front panel LEDs and Power Button USB connectors VGA port 2.5" Hot-Swap SATA/SAS HDDs NOTE! For Front LED description, please go to Switch and LED Indicators Introduction section.
Manual
Page 27
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server Front Panel LED Indicators No Indicator Color State 1 LAN1 Green On activity Green Blink 2 LAN2 Green On activity Green Blink 3 HDD Green Blink activity N/A Off 4 ...
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server Front Panel LED Indicators No Indicator Color State 1 LAN1 Green On activity Green Blink 2 LAN2 Green On activity Green Blink 3 HDD Green Blink activity N/A Off 4 ...
Manual
Page 28
... Color State 1 Speed N/A Off indicator Green On Yellow On 2 Link/activity Green On indicator Green Blink Description 10Mbps connection 100Mbps connection 1000Mbps connection Note: The server management port does not support 1000Mbps connection Active connection Transmit or receive connection 28
... Color State 1 Speed N/A Off indicator Green On Yellow On 2 Link/activity Green On indicator Green Blink Description 10Mbps connection 100Mbps connection 1000Mbps connection Note: The server management port does not support 1000Mbps connection Active connection Transmit or receive connection 28
Manual
Page 30
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server GC-BS28E-RH Back plane board Components Description (for 2.5"HDD) 8 9 10 11 12 13 14 15 7 17 16 2 19 1 18 4 3 20 22 6 5 21 No Code ...
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server GC-BS28E-RH Back plane board Components Description (for 2.5"HDD) 8 9 10 11 12 13 14 15 7 17 16 2 19 1 18 4 3 20 22 6 5 21 No Code ...