... is subject to the unit for future reference. These instructions should be retained and kept adjacent to change without notice. Installation & Operation Manual Air Handler 13 SEER 2 Ton Models: HB2400VD1M20 HB2400VD1V20 WARNING WHEN THIS APPLIANCE IS INSTALLED IN AN ENCLOSED AREA, SUCH AS A GARAGE OR UTILITY ROOM, WITH ANY CARBON MONOXIDE PRODUCING DEVICES...
... is subject to the unit for future reference. These instructions should be retained and kept adjacent to change without notice. Installation & Operation Manual Air Handler 13 SEER 2 Ton Models: HB2400VD1M20 HB2400VD1V20 WARNING WHEN THIS APPLIANCE IS INSTALLED IN AN ENCLOSED AREA, SUCH AS A GARAGE OR UTILITY ROOM, WITH ANY CARBON MONOXIDE PRODUCING DEVICES...
User Manual
Page 5
AIR FLOW ORIENTATION *Horizontal Right Discharge Tube and Drain conn. front (see page 6) Important: Remove the horizontal pan when unit is installed in unconditioned i.e. (Garage, Attic ) application, or downflow applications, and install insulation kit on vertical ( donut shape ) drain pan. *Upflow Discharge *Air Handler is factory ready for Upflow & Horizontal Right Discharge Application as shown. 5 front Horizontal Left Discharge Tube and Drain conn.
AIR FLOW ORIENTATION *Horizontal Right Discharge Tube and Drain conn. front (see page 6) Important: Remove the horizontal pan when unit is installed in unconditioned i.e. (Garage, Attic ) application, or downflow applications, and install insulation kit on vertical ( donut shape ) drain pan. *Upflow Discharge *Air Handler is factory ready for Upflow & Horizontal Right Discharge Application as shown. 5 front Horizontal Left Discharge Tube and Drain conn.
User Manual
Page 7
... DRAIN LINE(S) TO ALLOW FOR PROPER CONDENSATE DISPOSAL. The condensate trap must be adequately insulated. A joint compound should be at the tubing entrance to the air handler. All condensate drain lines and drain traps should be used not to avoid strain or vibration. Important: The evaporator coil is coated with the seams...
... DRAIN LINE(S) TO ALLOW FOR PROPER CONDENSATE DISPOSAL. The condensate trap must be adequately insulated. A joint compound should be at the tubing entrance to the air handler. All condensate drain lines and drain traps should be used not to avoid strain or vibration. Important: The evaporator coil is coated with the seams...
User Manual
Page 8
... to the Air Handler as the rating plate, included in the optional heat kit must be in accordance with local codes, or in absence of the unit. The wiring diagram included in that kit. Model No. Blower running Over-current Motor Ampacity 208/230 FLA 208/230 HB2400VD1M20 -------- 15...the wiring diagram on the exterior of local code, the National Electrical Code. When an optional electric heat kit is only for "HB" air handlers installed without a heat kit. 8 The ampacity and overcurrent protection shown above is installed refer to the electrical requirements in the heat kit ...
... to the Air Handler as the rating plate, included in the optional heat kit must be in accordance with local codes, or in absence of the unit. The wiring diagram included in that kit. Model No. Blower running Over-current Motor Ampacity 208/230 FLA 208/230 HB2400VD1M20 -------- 15...the wiring diagram on the exterior of local code, the National Electrical Code. When an optional electric heat kit is only for "HB" air handlers installed without a heat kit. 8 The ampacity and overcurrent protection shown above is installed refer to the electrical requirements in the heat kit ...