User Manual
Page 1
ProCurve Series 2900 Switches Installation and Getting Started Guide www.procurve.com
ProCurve Series 2900 Switches Installation and Getting Started Guide www.procurve.com
User Manual
Page 4
... replacement parts can be obtained from your HP Sales and Service Office or authorized dealer. Hewlett-Packard Company 8000 Foothills Boulevard, m/s 5552 Roseville, California 95747-5552 http://www.procurve.com Publication Number 5991-4737 September 2006 Applicable Products ProCurve Switch 2900-24G (J9049A) ProCurve Switch 2900-48G (J9050A) ProCurve 10-GbE X2 SR-SC Xcvr (J8436A...
... replacement parts can be obtained from your HP Sales and Service Office or authorized dealer. Hewlett-Packard Company 8000 Foothills Boulevard, m/s 5552 Roseville, California 95747-5552 http://www.procurve.com Publication Number 5991-4737 September 2006 Applicable Products ProCurve Switch 2900-24G (J9049A) ProCurve Switch 2900-48G (J9050A) ProCurve 10-GbE X2 SR-SC Xcvr (J8436A...
User Manual
Page 7
... Downloading New Switch Software 5-13 HP Customer Support Services 5-14 Before Calling Support 5-14 Specifications Physical A-1 Electrical A-1 Environmental A-1 Acoustic A-2 Connectors A-2 Safety A-2 Lasers A-3 Optical Power Specifications A-4 ProCurve 10-GbE X2-SC SR optic (J8436A A-4 ProCurve 10-GbE X2-SC LR optic (J8437A A-4 ProCurve 10-GbE X2-SC ER optic (J8438A A-5 ProCurve 10-GbE X2-CX4 Transceiver...
... Downloading New Switch Software 5-13 HP Customer Support Services 5-14 Before Calling Support 5-14 Specifications Physical A-1 Electrical A-1 Environmental A-1 Acoustic A-2 Connectors A-2 Safety A-2 Lasers A-3 Optical Power Specifications A-4 ProCurve 10-GbE X2-SC SR optic (J8436A A-4 ProCurve 10-GbE X2-SC LR optic (J8437A A-4 ProCurve 10-GbE X2-SC ER optic (J8438A A-5 ProCurve 10-GbE X2-CX4 Transceiver...
User Manual
Page 9
The Series 2900 Switches can be disabled. ProCurve Switch 2900-24G (J9049A) ! Use only one (T or S) for each Port Power Fault Locator ProCurve Switch 2900-24G J9049A * Spd Mode: Off = 10 Mbps Flash = 100 Mbps On = 1000 Mbps Status 10G RPS LED Mode Fan Test Act FDx Spd * Usr Reset Clear...are four 10-Gigabit per second Ethernet (10-GbE) ports (two fixed CX4 ports and two X2 transceiver bays) which can be connected to the ProCurve 620 Redundant and External Power Supply (RPS/EPS) and receive redundant power from that can be used to keep the switch running. 1-1 If any...
The Series 2900 Switches can be disabled. ProCurve Switch 2900-24G (J9049A) ! Use only one (T or S) for each Port Power Fault Locator ProCurve Switch 2900-24G J9049A * Spd Mode: Off = 10 Mbps Flash = 100 Mbps On = 1000 Mbps Status 10G RPS LED Mode Fan Test Act FDx Spd * Usr Reset Clear...are four 10-Gigabit per second Ethernet (10-GbE) ports (two fixed CX4 ports and two X2 transceiver bays) which can be connected to the ProCurve 620 Redundant and External Power Supply (RPS/EPS) and receive redundant power from that can be used to keep the switch running. 1-1 If any...
User Manual
Page 11
... each Port Power, Fault, and Locator LEDs 10G, RPS, Fan, and Test Status LEDs Auxiliary port and LED* Switch port LEDs Power Fault Locator ProCurve Switch 2900-24G J9049A * Spd Mode: Off = 10 Mbps Flash = 100 Mbps On = 1000 Mbps Status 10G RPS LED Mode Fan Test Act FDx Spd * Usr ... ports (1000Base-T or mini-GBIC) ! Front of the unit. Figure 1-1. Front of Switch Introducing the Switch ! Front of Switch Introducing the Switch Front of ProCurve Switch 2900-24G Power, Fault, and Locator LEDs 10G, RPS, Fan, and Test Status LEDs Switch port LEDs Power Fault Locator...
... each Port Power, Fault, and Locator LEDs 10G, RPS, Fan, and Test Status LEDs Auxiliary port and LED* Switch port LEDs Power Fault Locator ProCurve Switch 2900-24G J9049A * Spd Mode: Off = 10 Mbps Flash = 100 Mbps On = 1000 Mbps Status 10G RPS LED Mode Fan Test Act FDx Spd * Usr ... ports (1000Base-T or mini-GBIC) ! Front of the unit. Figure 1-1. Front of Switch Introducing the Switch ! Front of Switch Introducing the Switch Front of ProCurve Switch 2900-24G Power, Fault, and Locator LEDs 10G, RPS, Fan, and Test Status LEDs Switch port LEDs Power Fault Locator...
User Manual
Page 12
... device provides four 10-GbE ports, 2 fixed CX4 ports and 2 ports that can use either the 10/100/1000Base-T RJ-45 connector, or install a supported ProCurve mini-GBIC for either a CX4 or fiber optic X2 transceiver. 1-4 Use either straight-through or crossover twisted-pair cables to connect any network devices to...
... device provides four 10-GbE ports, 2 fixed CX4 ports and 2 ports that can use either the 10/100/1000Base-T RJ-45 connector, or install a supported ProCurve mini-GBIC for either a CX4 or fiber optic X2 transceiver. 1-4 Use either straight-through or crossover twisted-pair cables to connect any network devices to...
User Manual
Page 13
...; the mini-GBIC is self tested when it flickers as network traffic is received and transmitted through the switch console, the web browser interface, or ProCurve Manager. • if the port LED is on for example an RJ-45 port, and the switch Fault LED will blink simultaneously. Press the button...
...; the mini-GBIC is self tested when it flickers as network traffic is received and transmitted through the switch console, the web browser interface, or ProCurve Manager. • if the port LED is on for example an RJ-45 port, and the switch Fault LED will blink simultaneously. Press the button...
User Manual
Page 14
... 1-6 Auxiliary (green) Reserved for ports in Full Duplex Mode. RPS Status (green) On Flashing* Off Normal operation. Reset and Clear Buttons ProCurve Switch 2900-24G Power Fault Locator ProCurve Switch 2900-24G J9049A * Spd Mode: Off = 10 Mbps Flash = 100 Mbps On = 1000 Mbps Status 10G RPS LED Mode Fan Test Act FDx...
... 1-6 Auxiliary (green) Reserved for ports in Full Duplex Mode. RPS Status (green) On Flashing* Off Normal operation. Reset and Clear Buttons ProCurve Switch 2900-24G Power Fault Locator ProCurve Switch 2900-24G J9049A * Spd Mode: Off = 10 Mbps Flash = 100 Mbps On = 1000 Mbps Status 10G RPS LED Mode Fan Test Act FDx...
User Manual
Page 15
.... Clear Button This button is used when restoring the switch factory default configuration. Introducing the Switch Introducing the Switch Front of Switch ProCurve Switch 2900-48G Power Fault Locator ProCurve Switch 2900-48G J9050A *Spd Mode: Link 1 Mode Off = 10 Mbps, Flash = 100 Mbps, 3 5 7 On = 1000 Mbps 9 11 Status 10G Act RPS...
.... Clear Button This button is used when restoring the switch factory default configuration. Introducing the Switch Introducing the Switch Front of Switch ProCurve Switch 2900-48G Power Fault Locator ProCurve Switch 2900-48G J9050A *Spd Mode: Link 1 Mode Off = 10 Mbps, Flash = 100 Mbps, 3 5 7 On = 1000 Mbps 9 11 Status 10G Act RPS...
User Manual
Page 16
... , the port has no meaning for Link and Activity. FDx and Spd modes have been disabled through the switch console, the web browser interface, or ProCurve Manager. • if the port LED is one 10-GbE Port Status LED on , the port is enabled and receiving a link indication from the connected...
... , the port has no meaning for Link and Activity. FDx and Spd modes have been disabled through the switch console, the web browser interface, or ProCurve Manager. • if the port LED is one 10-GbE Port Status LED on , the port is enabled and receiving a link indication from the connected...
User Manual
Page 17
... 12 - 34 - 56 10-GbE Port Status Link Activity 10-GbE X2 Port A1 10-GbE Ports ProCurve Switch 2900-48G ProCurve Switch 2900 10-GbE Ports 10-GbE CX4/Stacking Ports A2 A3 10-GbE X2 Port A4 Console Port... 1-9 E7 - 12 - 34 - 56 10-GbE Port Status Link Activity 10-GbE X2 Port A1 ProCurve Switch 2900 10-GbE Ports 10-GbE CX4/Stacking Ports A2 A3 10-GbE X2 Port A4 10-GbE ...CX4 Ports 10-GbE X2 Transceiver Ports ProCurve Switch 2900-24G 12V System Power (RPS) Input CAUTION: MULTIPLE POWER SOURCES Disconnect AC power cord and...
... 12 - 34 - 56 10-GbE Port Status Link Activity 10-GbE X2 Port A1 10-GbE Ports ProCurve Switch 2900-48G ProCurve Switch 2900 10-GbE Ports 10-GbE CX4/Stacking Ports A2 A3 10-GbE X2 Port A4 Console Port... 1-9 E7 - 12 - 34 - 56 10-GbE Port Status Link Activity 10-GbE X2 Port A1 ProCurve Switch 2900 10-GbE Ports 10-GbE CX4/Stacking Ports A2 A3 10-GbE X2 Port A4 10-GbE ...CX4 Ports 10-GbE X2 Transceiver Ports ProCurve Switch 2900-24G 12V System Power (RPS) Input CAUTION: MULTIPLE POWER SOURCES Disconnect AC power cord and...
User Manual
Page 18
...power switch; Console Port This port is an accessory product for these switches. These switches automatically adjust to an active AC power source. The ProCurve 620 Redundant and External Power Supply (RPS/EPS) is used to connect a console to back up the power supply in the switch in chapter... "Installing the Switch." There are : ■ ProCurve 10-GbE X2 SR-SC Xcvr (J8436A) ■ ProCurve 10-GbE X2 LR-SC Xcvr (J8437A) ■ ProCurve 10-GbE X2 ER-SC Xcvr (J8438A) ■ ProCurve 10-GbE CX4 Media Converter (J8439A) ■ ProCurve 10-GbE X2 CX4 Xcvr (J8440A) RPS Input ...
...power switch; Console Port This port is an accessory product for these switches. These switches automatically adjust to an active AC power source. The ProCurve 620 Redundant and External Power Supply (RPS/EPS) is used to connect a console to back up the power supply in the switch in chapter... "Installing the Switch." There are : ■ ProCurve 10-GbE X2 SR-SC Xcvr (J8436A) ■ ProCurve 10-GbE X2 LR-SC Xcvr (J8437A) ■ ProCurve 10-GbE X2 ER-SC Xcvr (J8438A) ■ ProCurve 10-GbE CX4 Media Converter (J8439A) ■ ProCurve 10-GbE X2 CX4 Xcvr (J8440A) RPS Input ...
User Manual
Page 19
...-just connect the network cables to active network devices and your switched network is reserved for future development. ■ The switches can be connected to a ProCurve 620 RPS/EPS and receive redundant system power from common web browsers. 1-11 The pin operation of each port. ■ Four 10-GbE ports: Two...
...-just connect the network cables to active network devices and your switched network is reserved for future development. ■ The switches can be connected to a ProCurve 620 RPS/EPS and receive redundant system power from common web browsers. 1-11 The pin operation of each port. ■ Four 10-GbE ports: Two...
User Manual
Page 20
This product is on the ProCurve Web site, www.procurve.com. (See page 5-1 for details.) ■ Download of new switch software for product enhancements. 1-12 It adds many advanced features to manage your new switch. ...For a description, see the Management and Configuration Guide, which is included with your entire network. Introducing the Switch Introducing the Switch Switch Features • ProCurve Manager-an SNMP-based, graphical network management tool that you can divide the attached end nodes into logical groupings that fit your business needs. ■...
This product is on the ProCurve Web site, www.procurve.com. (See page 5-1 for details.) ■ Download of new switch software for product enhancements. 1-12 It adds many advanced features to manage your new switch. ...For a description, see the Management and Configuration Guide, which is included with your entire network. Introducing the Switch Introducing the Switch Switch Features • ProCurve Manager-an SNMP-based, graphical network management tool that you can divide the attached end nodes into logical groupings that fit your business needs. ■...
User Manual
Page 21
... the switch to install the switch. If the switch is to use only an HP 10K rack. Mount the switch using rail kit, ProCurve 1U RK MT SWITCH 10K ALL, part number 356578-B21 and shelf kit AB469A, HP rx 16/26 Factory Rack Mount Shelf Kit. Installing the Switch 2 Installing the Switch... Caution The ProCurve Series 2900 Switches come with an accessory kit that can be attached so...
... the switch to install the switch. If the switch is to use only an HP 10K rack. Mount the switch using rail kit, ProCurve 1U RK MT SWITCH 10K ALL, part number 356578-B21 and shelf kit AB469A, HP rx 16/26 Factory Rack Mount Shelf Kit. Installing the Switch 2 Installing the Switch... Caution The ProCurve Series 2900 Switches come with an accessory kit that can be attached so...
User Manual
Page 27
... printed, the supported transceivers and accessories include the following: ■ ProCurve 10-GbE X2 SR-SC Xcvr (J8436A) ■ ProCurve 10-GbE X2 LR-SC Xcvr (J8437A) ■ ProCurve 10-GbE X2 ER-SC Xcvr (J8438A) ■ ProCurve 10-GbE CX4 Media Converter (J8439A) ■ ProCurve 10-GbE X2 CX4 Xcvr (J8440A) a. Slide the transceiver...
... printed, the supported transceivers and accessories include the following: ■ ProCurve 10-GbE X2 SR-SC Xcvr (J8436A) ■ ProCurve 10-GbE X2 LR-SC Xcvr (J8437A) ■ ProCurve 10-GbE X2 ER-SC Xcvr (J8438A) ■ ProCurve 10-GbE CX4 Media Converter (J8439A) ■ ProCurve 10-GbE X2 CX4 Xcvr (J8440A) a. Slide the transceiver...
User Manual
Page 29
...cannot be used. ■ The mini-GBIC ports operate only at full duplex. NonProCurve mini-GBICs are Class 1 laser devices. The ProCurve mini-GBICs are not supported, and their use may result in a slot, the associated RJ-45 port is NOT connected when you require additional... was printed, the supported mini-GBICs include the following: ■ ProCurve Gigabit-SX-LC mini-GBIC (J4858B) ■ ProCurve Gigabit-LX-LC mini-GBIC (J4859B) ■ ProCurve Gigabit-LH-LC mini-GBIC (J4860B) Use only supported genuine ProCurve mini-GBICs with the four 10/100/1000Base-T RJ-45 ports. ...
...cannot be used. ■ The mini-GBIC ports operate only at full duplex. NonProCurve mini-GBICs are Class 1 laser devices. The ProCurve mini-GBICs are not supported, and their use may result in a slot, the associated RJ-45 port is NOT connected when you require additional... was printed, the supported mini-GBICs include the following: ■ ProCurve Gigabit-SX-LC mini-GBIC (J4858B) ■ ProCurve Gigabit-LX-LC mini-GBIC (J4859B) ■ ProCurve Gigabit-LH-LC mini-GBIC (J4860B) Use only supported genuine ProCurve mini-GBICs with the four 10/100/1000Base-T RJ-45 ports. ...
User Manual
Page 30
... Switch Installation Procedures Removing the mini-GBICs: Caution Disconnect the network cable from the mini-GBIC before removing it from the switch (you purchased your ProCurve mini-GBIC, it may have either of the mini-GBIC, a plastic collar around the mini-GBIC, or a wire bail.
... Switch Installation Procedures Removing the mini-GBICs: Caution Disconnect the network cable from the mini-GBIC before removing it from the switch (you purchased your ProCurve mini-GBIC, it may have either of the mini-GBIC, a plastic collar around the mini-GBIC, or a wire bail.
User Manual
Page 32
...8226; The Power and Fan Status LEDs remain on , it performs its diagnostic self test. Switch port LEDs ProCurve Switch 2900-24G Power and Fault LEDs Power Fault Locator ProCurve Switch 2900-24G J9049A * Spd Mode: Status 10G RPS LED Mode Fan Test Act FDx Spd * Usr Reset Clear Off =... Mode 3 5 7 9 11 Link 13 Mode 15 17 Link 2 Mode 4 6 8 10 12 Link 14 Mode 16 18 Switch port LEDs ProCurve Switch 2900-48G Power and Fault LEDs Power Fault Locator ProCurve Switch 2900-48G J9050A *Spd Mode: Link 1 Mode Off = 10 Mbps, Flash = 100 Mbps, 3 5 7 On = 1000 Mbps 9 11...
...8226; The Power and Fan Status LEDs remain on , it performs its diagnostic self test. Switch port LEDs ProCurve Switch 2900-24G Power and Fault LEDs Power Fault Locator ProCurve Switch 2900-24G J9049A * Spd Mode: Status 10G RPS LED Mode Fan Test Act FDx Spd * Usr Reset Clear Off =... Mode 3 5 7 9 11 Link 13 Mode 15 17 Link 2 Mode 4 6 8 10 12 Link 14 Mode 16 18 Switch port LEDs ProCurve Switch 2900-48G Power and Fault LEDs Power Fault Locator ProCurve Switch 2900-48G J9050A *Spd Mode: Link 1 Mode Off = 10 Mbps, Flash = 100 Mbps, 3 5 7 On = 1000 Mbps 9 11...