User Manual
Page 4
... contained herein is subject to your HP Sales and Service Office or authorized dealer. No part of Hewlett-Packard. Hewlett-Packard Company 8000 Foothills Boulevard, m/s 5552 Roseville, California 95747-5552 http://www.procurve.com Publication Number 5991-4737 September 2006 Applicable Products ProCurve Switch 2900-24G (J9049A) ProCurve Switch 2900-48G (J9050A) ProCurve 10-GbE X2 SR-SC Xcvr...
... contained herein is subject to your HP Sales and Service Office or authorized dealer. No part of Hewlett-Packard. Hewlett-Packard Company 8000 Foothills Boulevard, m/s 5552 Roseville, California 95747-5552 http://www.procurve.com Publication Number 5991-4737 September 2006 Applicable Products ProCurve Switch 2900-24G (J9049A) ProCurve Switch 2900-48G (J9050A) ProCurve 10-GbE X2 SR-SC Xcvr...
User Manual
Page 9
... Link 21S Mode 23S Link 2 Mode 4 6 8 10 12 Link 14 Mode 16 18 20 22T 24T Link 22S Mode 24S ProCurve Switch 2900-48G (J9050A) ! ProCurve Switch 2900-24G (J9049A) ! The Series 2900 Switches can be used to build high-performance switched networks. Use only one (T or S) for each Port Power Fault Locator... ProCurve Switch 2900-24G J9049A * Spd Mode: Off = 10 Mbps Flash = 100 Mbps On = 1000 Mbps Status 10G RPS LED Mode Fan Test Act FDx Spd * ...
... Link 21S Mode 23S Link 2 Mode 4 6 8 10 12 Link 14 Mode 16 18 20 22T 24T Link 22S Mode 24S ProCurve Switch 2900-48G (J9050A) ! ProCurve Switch 2900-24G (J9049A) ! The Series 2900 Switches can be used to build high-performance switched networks. Use only one (T or S) for each Port Power Fault Locator... ProCurve Switch 2900-24G J9049A * Spd Mode: Off = 10 Mbps Flash = 100 Mbps On = 1000 Mbps Status 10G RPS LED Mode Fan Test Act FDx Spd * ...
User Manual
Page 11
...Port Power, Fault, and Locator LEDs 10G, RPS, Fan, and Test Status LEDs Auxiliary port and LED* Switch port LEDs Power Fault Locator ProCurve Switch 2900-24G J9049A * Spd Mode: Off = 10 Mbps Flash = 100 Mbps On = 1000 Mbps Status 10G RPS LED Mode Fan Test Act FDx Spd ...10/100/1000Base-T RJ-45 ports Dual-personality ports (1000Base-T or mini-GBIC) ! Front of ProCurve Switch 2900-24G Power, Fault, and Locator LEDs 10G, RPS, Fan, and Test Status LEDs Switch port LEDs Power Fault Locator ProCurve Switch 2900-48G J9050A *Spd Mode: Link 1 Mode Off = 10 Mbps, Flash = 100 Mbps, ...
...Port Power, Fault, and Locator LEDs 10G, RPS, Fan, and Test Status LEDs Auxiliary port and LED* Switch port LEDs Power Fault Locator ProCurve Switch 2900-24G J9049A * Spd Mode: Off = 10 Mbps Flash = 100 Mbps On = 1000 Mbps Status 10G RPS LED Mode Fan Test Act FDx Spd ...10/100/1000Base-T RJ-45 ports Dual-personality ports (1000Base-T or mini-GBIC) ! Front of ProCurve Switch 2900-24G Power, Fault, and Locator LEDs 10G, RPS, Fan, and Test Status LEDs Switch port LEDs Power Fault Locator ProCurve Switch 2900-48G J9050A *Spd Mode: Link 1 Mode Off = 10 Mbps, Flash = 100 Mbps, ...
User Manual
Page 14
... 10/100/1000Base-T Link 1 Mode 3 5 7 9 Link 2 Mode 4 6 8 10 Reset Button Clear Button 1-6 RPS is connected and operating correctly. Reset and Clear Buttons ProCurve Switch 2900-24G Power Fault Locator ProCurve Switch 2900-24G J9049A * Spd Mode: Off = 10 Mbps Flash = 100 Mbps On = 1000 Mbps Status 10G RPS LED Mode Fan Test Act FDx Spd * Usr Reset...
... 10/100/1000Base-T Link 1 Mode 3 5 7 9 Link 2 Mode 4 6 8 10 Reset Button Clear Button 1-6 RPS is connected and operating correctly. Reset and Clear Buttons ProCurve Switch 2900-24G Power Fault Locator ProCurve Switch 2900-24G J9049A * Spd Mode: Off = 10 Mbps Flash = 100 Mbps On = 1000 Mbps Status 10G RPS LED Mode Fan Test Act FDx Spd * Usr Reset...
User Manual
Page 17
SG12345678 System MAC Address 00 - 01 - E7 - 12 - 34 - 56 10-GbE Port Status Link Activity 10-GbE X2 Port A1 10-GbE Ports ProCurve Switch 2900-48G ProCurve Switch 2900 10-GbE Ports 10-GbE CX4/Stacking Ports A2 A3 10-GbE X2 Port A4 Console Port to be used by future software release...-GbE Ports 10-GbE CX4/Stacking Ports A2 A3 10-GbE X2 Port A4 10-GbE CX4 Ports 10-GbE X2 Transceiver Ports ProCurve Switch 2900-24G 12V System Power (RPS) Input CAUTION: MULTIPLE POWER SOURCES Disconnect AC power cord and RPS cable to completely remove power from the unit. Line: 50/...
SG12345678 System MAC Address 00 - 01 - E7 - 12 - 34 - 56 10-GbE Port Status Link Activity 10-GbE X2 Port A1 10-GbE Ports ProCurve Switch 2900-48G ProCurve Switch 2900 10-GbE Ports 10-GbE CX4/Stacking Ports A2 A3 10-GbE X2 Port A4 Console Port to be used by future software release...-GbE Ports 10-GbE CX4/Stacking Ports A2 A3 10-GbE X2 Port A4 10-GbE CX4 Ports 10-GbE X2 Transceiver Ports ProCurve Switch 2900-24G 12V System Power (RPS) Input CAUTION: MULTIPLE POWER SOURCES Disconnect AC power cord and RPS cable to completely remove power from the unit. Line: 50/...
User Manual
Page 18
...support a number of the Switch The 10-GbE Ports These switches support four 10-GbE ports. The ProCurve 620 Redundant and External Power Supply (RPS/EPS) is located on the front of the 2900-24G and on when connected to a redundant power supply. Console Port This port is described under "Connect a...X2 SR-SC Xcvr (J8436A) ■ ProCurve 10-GbE X2 LR-SC Xcvr (J8437A) ■ ProCurve 10-GbE X2 ER-SC Xcvr (J8438A) ■ ProCurve 10-GbE CX4 Media Converter (J8439A) ■ ProCurve 10-GbE X2 CX4 Xcvr (J8440A) RPS Input Port The Series 2900 Switches support connectivity to an active AC ...
...support a number of the Switch The 10-GbE Ports These switches support four 10-GbE ports. The ProCurve 620 Redundant and External Power Supply (RPS/EPS) is located on the front of the 2900-24G and on when connected to a redundant power supply. Console Port This port is described under "Connect a...X2 SR-SC Xcvr (J8436A) ■ ProCurve 10-GbE X2 LR-SC Xcvr (J8437A) ■ ProCurve 10-GbE X2 ER-SC Xcvr (J8438A) ■ ProCurve 10-GbE CX4 Media Converter (J8439A) ■ ProCurve 10-GbE X2 CX4 Xcvr (J8440A) RPS Input Port The Series 2900 Switches support connectivity to an active AC ...
User Manual
Page 32
... 3 5 7 9 11 Link 13 Mode 15 17 Link 2 Mode 4 6 8 10 12 Link 14 Mode 16 18 Switch port LEDs ProCurve Switch 2900-48G Power and Fault LEDs Power Fault Locator ProCurve Switch 2900-48G J9050A *Spd Mode: Link 1 Mode Off = 10 Mbps, Flash = 100 Mbps, 3 5 7 On = 1000 Mbps 9 11 ... test, the Test LED stays on the switch as described below. Check the LEDs on . Switch port LEDs ProCurve Switch 2900-24G Power and Fault LEDs Power Fault Locator ProCurve Switch 2900-24G J9049A * Spd Mode: Status 10G RPS LED Mode Fan Test Act FDx Spd * Usr Reset Clear Off = 10...
... 3 5 7 9 11 Link 13 Mode 15 17 Link 2 Mode 4 6 8 10 12 Link 14 Mode 16 18 Switch port LEDs ProCurve Switch 2900-48G Power and Fault LEDs Power Fault Locator ProCurve Switch 2900-48G J9050A *Spd Mode: Link 1 Mode Off = 10 Mbps, Flash = 100 Mbps, 3 5 7 On = 1000 Mbps 9 11 ... test, the Test LED stays on the switch as described below. Check the LEDs on . Switch port LEDs ProCurve Switch 2900-24G Power and Fault LEDs Power Fault Locator ProCurve Switch 2900-24G J9049A * Spd Mode: Status 10G RPS LED Mode Fan Test Act FDx Spd * Usr Reset Clear Off = 10...
User Manual
Page 39
...Enter] two or three times and you want to the switch's Console Port using the Console port P ower F ault Locator ProC ur ve Switc h 2900-2 4G J9049A S tatus 10G Act RPS LED Mode FDx Fan Spd * Test Usr Reset Clear Console * Spd Mode: Off = 10 Mbps Flash = 100 Mbps...adapter at one end of the switch at this time, see chapter 3, "Getting Started With Switch Configuration" for example: ProCurve Switch 2900-24G# If you will then see the 2900-24G. Change the switch settings first, save your switch. Remember the console port on the terminal or PC running a terminal ...
...Enter] two or three times and you want to the switch's Console Port using the Console port P ower F ault Locator ProC ur ve Switc h 2900-2 4G J9049A S tatus 10G Act RPS LED Mode FDx Fan Spd * Test Usr Reset Clear Console * Spd Mode: Off = 10 Mbps Flash = 100 Mbps...adapter at one end of the switch at this time, see chapter 3, "Getting Started With Switch Configuration" for example: ProCurve Switch 2900-24G# If you will then see the 2900-24G. Change the switch settings first, save your switch. Remember the console port on the terminal or PC running a terminal ...
User Manual
Page 43
Installing the Switch Installing the Switch Installation Procedures 620 RPS/EPS Connectivity This section shows some recommended connection topologies using the 620 RPS/EPS. Figure 2-2. In the illustration below, two ProCurve Switch 2900-24G units are connected to two ProCurve switches. The 620 RPS/EPS can provide backup power support for up to the RPS ports on a 620 RPS/EPS. Connecting RPS to 2, 24 port switches. 2-23
Installing the Switch Installing the Switch Installation Procedures 620 RPS/EPS Connectivity This section shows some recommended connection topologies using the 620 RPS/EPS. Figure 2-2. In the illustration below, two ProCurve Switch 2900-24G units are connected to two ProCurve switches. The 620 RPS/EPS can provide backup power support for up to the RPS ports on a 620 RPS/EPS. Connecting RPS to 2, 24 port switches. 2-23
User Manual
Page 44
... is designed to be used primarily as a desktop switch to the switch by straight-through or crossover twisted-pair cables. Server with Gigabit Ethernet NIC ProCurve Switch 2900-24G To Backbone 10 Gigabit Copper cable Fast Ethernet cable Gigabit Ethernet cable PCs, local servers, and peripherals Figure 2-3.
... is designed to be used primarily as a desktop switch to the switch by straight-through or crossover twisted-pair cables. Server with Gigabit Ethernet NIC ProCurve Switch 2900-24G To Backbone 10 Gigabit Copper cable Fast Ethernet cable Gigabit Ethernet cable PCs, local servers, and peripherals Figure 2-3.
User Manual
Page 45
Desktop configuration with Gigabit Ethernet NIC ProCurve Switch 2900-24G Fast Ethernet cable To Backbone 10 Gigabit Copper cable Gigabit Ethernet cable PCs, local servers, and peripherals Figure 2-4. As shown in Figure 2-4, both switches can be connected to a single 620 RPS to receive power should either of the switch's internal power supplies fail. Installing the Switch 2-25 Installing the Switch Sample Network Topologies RPS Cables Server with a 620 RPS connected.
Desktop configuration with Gigabit Ethernet NIC ProCurve Switch 2900-24G Fast Ethernet cable To Backbone 10 Gigabit Copper cable Gigabit Ethernet cable PCs, local servers, and peripherals Figure 2-4. As shown in Figure 2-4, both switches can be connected to a single 620 RPS to receive power should either of the switch's internal power supplies fail. Installing the Switch 2-25 Installing the Switch Sample Network Topologies RPS Cables Server with a 620 RPS connected.
User Manual
Page 46
..." Ethernet hubs with Gigabit Ethernet NIC 10 Gigabit Copper cable To Backbone Installing the Switch Figure 2-5. As a Segment Switch. Installing the Switch Sample Network Topologies ProCurve Switch 2900-24G Server with PCs, printers, and local servers attached, are both connected to a Switch.
..." Ethernet hubs with Gigabit Ethernet NIC 10 Gigabit Copper cable To Backbone Installing the Switch Figure 2-5. As a Segment Switch. Installing the Switch Sample Network Topologies ProCurve Switch 2900-24G Server with PCs, printers, and local servers attached, are both connected to a Switch.
User Manual
Page 47
... To IT or Data Center PCs, local servers, and peripherals Servers with Gigabit Ethernet NIC ProCurve Switch 2900-24G ProCurve Switch 2900-48G Servers with Gigabit Ethernet NIC Fast Ethernet Switch Fast Ethernet Switch 10 Gigabit fiber cables Servers with Gigabit Ethernet NIC 2-27 Connecting to a Gigabit-...
... To IT or Data Center PCs, local servers, and peripherals Servers with Gigabit Ethernet NIC ProCurve Switch 2900-24G ProCurve Switch 2900-48G Servers with Gigabit Ethernet NIC Fast Ethernet Switch Fast Ethernet Switch 10 Gigabit fiber cables Servers with Gigabit Ethernet NIC 2-27 Connecting to a Gigabit-...
User Manual
Page 48
... as shown in figure 2-3. The management includes Telnet access and web browser interface access to the Commander and to each of two 2900-24G switches using copper cables trunked. Stacking Switches 2-28 Through switch console commands, you could be connected together, through standard network connections,...address. Up to 15 other . For more information on stacking Switches, please see the Management and Configuration Guide, which is on ProCurve Web site, www.procurve.com. (See page 5-1 for example, in such a "virtual stack". Figure 2-7. For example, you can identify one of the...
... as shown in figure 2-3. The management includes Telnet access and web browser interface access to the Commander and to each of two 2900-24G switches using copper cables trunked. Stacking Switches 2-28 Through switch console commands, you could be connected together, through standard network connections,...address. Up to 15 other . For more information on stacking Switches, please see the Management and Configuration Guide, which is on ProCurve Web site, www.procurve.com. (See page 5-1 for example, in such a "virtual stack". Figure 2-7. For example, you can identify one of the...
User Manual
Page 49
... state, the 10-GbE ports support an aggregate bandwidth of three 2900-24G switches using CX4 only and not trunked. Installing the Switch Sample Network Topologies Figure 2-8. Optimizing the 10-GbE Port Configuration The 10-GbE ports on the ProCurve Switch 2900 series are designed to deliver full 10 Gbps wire-speed to each...
... state, the 10-GbE ports support an aggregate bandwidth of three 2900-24G switches using CX4 only and not trunked. Installing the Switch Sample Network Topologies Figure 2-8. Optimizing the 10-GbE Port Configuration The 10-GbE ports on the ProCurve Switch 2900 series are designed to deliver full 10 Gbps wire-speed to each...
User Manual
Page 80
... IEEE 802.3z Gigabit-SX and Gigabit-LX standards. Specifications Specifications Acoustic ProCurve Switch 2900-24G (J9049A) Geraeuschemission LpA=53.1 dB am fiktiven Arbeitsplatz nach DIN 45635 T.19 Noise Emission LpA=53.1 dB at virtual workspace according to DIN 45635 T.19 ProCurve Switch 2900-48G (J9050A) Geraeuschemission LpA=55.8 dB am fiktiven Arbeitsplatz nach DIN 45635...
... IEEE 802.3z Gigabit-SX and Gigabit-LX standards. Specifications Specifications Acoustic ProCurve Switch 2900-24G (J9049A) Geraeuschemission LpA=53.1 dB am fiktiven Arbeitsplatz nach DIN 45635 T.19 Noise Emission LpA=53.1 dB at virtual workspace according to DIN 45635 T.19 ProCurve Switch 2900-48G (J9050A) Geraeuschemission LpA=55.8 dB am fiktiven Arbeitsplatz nach DIN 45635...
User Manual
Page 102
... Directive 73/23/EEC and the EMC Directive 89/336/EEC and carries the CE marking accordingly. declares, that the product Product Name: ProCurve Switch 2900 - 24G ProCurve Switch 2900 - 48G Product Number(s): J9049A, J9050A Regulatory Model: RSVLC-0602 Product Options: J4858B, J4859B, J4860B, J8177B, J8436A, J8437A, J8438A, J8439A, J8440A, J8694A, J8696A conforms to ISO/IEC...
... Directive 73/23/EEC and the EMC Directive 89/336/EEC and carries the CE marking accordingly. declares, that the product Product Name: ProCurve Switch 2900 - 24G ProCurve Switch 2900 - 48G Product Number(s): J9049A, J9050A Regulatory Model: RSVLC-0602 Product Options: J4858B, J4859B, J4860B, J8177B, J8436A, J8437A, J8438A, J8439A, J8440A, J8694A, J8696A conforms to ISO/IEC...