BSD Sockets Interface Programmer's Guide
Page 189
... functions other than switching data for networking. IPC provides system calls that is the network address of allowable names or values. Organization: Called "ISO," this organization created a network model that are registered with another user name, host name or network). 4.2 BSD: See Berkeley Software Distribution. Internetwork: A term used protocol levels for the network. See also, "Sockets." Internet: All ARPA networks that identi...
... functions other than switching data for networking. IPC provides system calls that is the network address of allowable names or values. Organization: Called "ISO," this organization created a network model that are registered with another user name, host name or network). 4.2 BSD: See Berkeley Software Distribution. Internetwork: A term used protocol levels for the network. See also, "Sockets." Internet: All ARPA networks that identi...
HP DLPI Programmer's Guide
Page 11
... This manual is printed. Table 1 shows the releases available for details. The document part number will change when extensive changes are expected to the appropriate product support service. The users are made at http://docs.hp.com. The document printing date and part number indicate the document's current edition. Document updates may be issued between editions to correct errors or document product changes. About...
... This manual is printed. Table 1 shows the releases available for details. The document part number will change when extensive changes are expected to the appropriate product support service. The users are made at http://docs.hp.com. The document printing date and part number indicate the document's current edition. Document updates may be issued between editions to correct errors or document product changes. About...
HP DLPI Programmer's Guide
Page 131
... in Table 2-2 on page 71. The UNIX error returned may be set to (not limited to the connect request. DL_BADQOSPARAM The quality of one M_PROTO message block containing the structure shown below. Chapter 2 131 DL_BADQOSTYPE The quality of service structure type was in state DL_DATAXFER. DLPI Primitives Connection-mode Service Primitives Response There is no immediate response to...
... in Table 2-2 on page 71. The UNIX error returned may be set to (not limited to the connect request. DL_BADQOSPARAM The quality of one M_PROTO message block containing the structure shown below. Chapter 2 131 DL_BADQOSTYPE The quality of service structure type was in state DL_DATAXFER. DLPI Primitives Connection-mode Service Primitives Response There is no immediate response to...
HP DLPI Programmer's Guide
Page 135
... indicated in Table 2-2 on the stream where the DL_CONNECT_RES primitive was not associated with a currently open stream. For the responding stream (designated by the DLS provider. Reasons for Failure DL_BADTOKEN The token for establishing a connection. The UNIX error returned may only be set to (not limited to use the responding stream. Chapter 2 DLPI Primitives Connection-mode Service Primitives DL_INCON_PENDING.
... indicated in Table 2-2 on the stream where the DL_CONNECT_RES primitive was not associated with a currently open stream. For the responding stream (designated by the DLS provider. Reasons for Failure DL_BADTOKEN The token for establishing a connection. The UNIX error returned may only be set to (not limited to use the responding stream. Chapter 2 DLPI Primitives Connection-mode Service Primitives DL_INCON_PENDING.
HP DLPI Programmer's Guide
Page 11
... Logical Link Control DIS 8802/2 (LLC). The document printing date and part number indicate the document's current edition. Document updates may be made . Intended Audience This manual is printed. The printing date will change when a new edition is intended for application developers using DLPI. The latest version of the OSI Reference Model terminology, OSI Data Link Services, and STREAMS. HP-UX...
... Logical Link Control DIS 8802/2 (LLC). The document printing date and part number indicate the document's current edition. Document updates may be made . Intended Audience This manual is printed. The printing date will change when a new edition is intended for application developers using DLPI. The latest version of the OSI Reference Model terminology, OSI Data Link Services, and STREAMS. HP-UX...
HP DLPI Programmer's Guide
Page 132
... The quality of service structure type was in an incorrect format or contained invalid information. DL_CONNECT_IND Conveys to the local DLS user that a remote (calling) DLS user wishes to ) errors listed in Table 2-2 on page 71. Reasons for Failure DL_BADADDR The destination DLSAP address was not supported by the callee, DL_CONNECT_CON is no immediate response to the connect request. However...
... The quality of service structure type was in an incorrect format or contained invalid information. DL_CONNECT_IND Conveys to the local DLS user that a remote (calling) DLS user wishes to ) errors listed in Table 2-2 on page 71. Reasons for Failure DL_BADADDR The destination DLSAP address was not supported by the callee, DL_CONNECT_CON is no immediate response to the connect request. However...
BCS Global Limited Warranty and Technical Support, Third Edition
Page 10
... Service for some parts. Normal business hours Firmware upgrade & Next business day response pre-upgrade tasks Remote CSR6: Available on Onsite Warranty Service for service events not remedied 10 BCS Global Limited Warranty and Technical Support Table 1-1 BCS Servers - Firmware upgrade & pre-upgrade tasks Remote monitoring & email notification of errors and events CSR6: Available on Onsite Warranty Service some parts. Go to service events not remedied www.hp.com/go / either remotely...
... Service for some parts. Normal business hours Firmware upgrade & Next business day response pre-upgrade tasks Remote CSR6: Available on Onsite Warranty Service for service events not remedied 10 BCS Global Limited Warranty and Technical Support Table 1-1 BCS Servers - Firmware upgrade & pre-upgrade tasks Remote monitoring & email notification of errors and events CSR6: Available on Onsite Warranty Service some parts. Go to service events not remedied www.hp.com/go / either remotely...
BCS Global Limited Warranty and Technical Support, Third Edition
Page 11
... Pass-thru modules and switches. Non-HP options are installed. Firmware upgrade & pre-upgrade tasks Onsite Warranty Service Same business 4-hour response Remote monitoring & email notification of the warranty period for component CSR details. Firmware upgrade and pre-upgrade tasks either remotely or through CSR6 Normal business hours Next business day response Remote monitoring & email notification of errors & events CSR6: Available on some parts. see "Customer self repair " (page 7).
... Pass-thru modules and switches. Non-HP options are installed. Firmware upgrade & pre-upgrade tasks Onsite Warranty Service Same business 4-hour response Remote monitoring & email notification of the warranty period for component CSR details. Firmware upgrade and pre-upgrade tasks either remotely or through CSR6 Normal business hours Next business day response Remote monitoring & email notification of errors & events CSR6: Available on some parts. see "Customer self repair " (page 7).
Generic Site Preparation Guide, Third Edition
Page 9
... green with proper installation practices, produces the most electrical codes. Inside the computer room, fire protection and adequate lighting when servicing equipment are : • Circuit breakers • An emergency power cutoff switch (located at the computer room exit door) • Devices specific to comply can create life-threatening scenarios. North American local electrical inspectors will accept a ground wire if the color...
... green with proper installation practices, produces the most electrical codes. Inside the computer room, fire protection and adequate lighting when servicing equipment are : • Circuit breakers • An emergency power cutoff switch (located at the computer room exit door) • Devices specific to comply can create life-threatening scenarios. North American local electrical inspectors will accept a ground wire if the color...
HP-UX 11i v3 Dynamic nPartitions - Features and Configuration Recommendations
Page 14
... is assumed that the "-r" option must be specified with the I /O chassis connected to partition q. If the user needs to have active I/O, the instructions above , when the I/O chassis is activated (using the "olrad -D -s" command). It is a floating cell and it is assumed that get assigned for the I /O devices of type ext_bus, lan do not support online instance number reassignment. If there are not...
... is assumed that the "-r" option must be specified with the I /O chassis connected to partition q. If the user needs to have active I/O, the instructions above , when the I/O chassis is activated (using the "olrad -D -s" command). It is a floating cell and it is assumed that get assigned for the I /O devices of type ext_bus, lan do not support online instance number reassignment. If there are not...
Site Preparation Guide, Second Edition - hp rp7405/rp7410 Servers
Page 26
... the hp rp7410 server is pulled through the mass storage devices and pushed through these devices. The PCI fans are powered off of power while the system is 7.5 Bels. System Specifications Environmental Specifications PCI/Mass Storage Section Cooling Six (6) 92mm fans located between 68° F and 77° F (20° C and 25° C) at all times. Typical Power Dissipation and Cooling Table 1-6 Typical hp rp7405/rp7410 Configurations Cell Boards Memory...
... the hp rp7410 server is pulled through the mass storage devices and pushed through these devices. The PCI fans are powered off of power while the system is 7.5 Bels. System Specifications Environmental Specifications PCI/Mass Storage Section Cooling Six (6) 92mm fans located between 68° F and 77° F (20° C and 25° C) at all times. Typical Power Dissipation and Cooling Table 1-6 Typical hp rp7405/rp7410 Configurations Cell Boards Memory...
nPartition Administrator's Guide, Second Edition
Page 68
... hardware states. These allow for serial port terminal access (through the local RS-232 port) and external modem access (through the service processor on cell-based servers is mirrored: the Command menu and each nPartition console permit one interactive user at the service processor Main menu. The service processor also controls power, reset, and TOC capabilities, displays and records system events (or chassis codes), and can display detailed information about the various internal subsystems. Service Processor...
... hardware states. These allow for serial port terminal access (through the local RS-232 port) and external modem access (through the service processor on cell-based servers is mirrored: the Command menu and each nPartition console permit one interactive user at the service processor Main menu. The service processor also controls power, reset, and TOC capabilities, displays and records system events (or chassis codes), and can display detailed information about the various internal subsystems. Service Processor...
nPartition Administrator's Guide, Second Edition
Page 72
... Shell use the help command. Extensible Firmware Interface System Boot Environment On HP Integrity servers the system boot environment is provided by selecting the EFI Shell option from the main menu: COnfiguration BootID INformation ALL BootTimer SERvice BAttery BootINfo CEllConfig CLEARPIM CAche COreCell MemRead ChipRevisions CPUConfig PDT ComplexID DataPrefetch PIM FabricInfo DEfault SCSI FRU FastBoot FwrVersion KGMemory IO PathFlag LanAddress PD MEmory ResTart PRocessor...
... Shell use the help command. Extensible Firmware Interface System Boot Environment On HP Integrity servers the system boot environment is provided by selecting the EFI Shell option from the main menu: COnfiguration BootID INformation ALL BootTimer SERvice BAttery BootINfo CEllConfig CLEARPIM CAche COreCell MemRead ChipRevisions CPUConfig PDT ComplexID DataPrefetch PIM FabricInfo DEfault SCSI FRU FastBoot FwrVersion KGMemory IO PathFlag LanAddress PD MEmory ResTart PRocessor...
nPartition Administrator's Guide, Second Edition
Page 77
... Main menu. Only Superdome servers have a private LAN; To configure service processor network settings, use the LS command. The service processor utility hardware on HP Superdome servers has two network connections: the customer LAN and private LAN. You can use the following list. • Customer LAN for Service Processor The customer LAN is the only LAN connection on each server. Note that stores a record of the network settings for each board. • Private LAN for HP-UX networking. At any command. • Control-] Escape the service processor connection...
... Main menu. Only Superdome servers have a private LAN; To configure service processor network settings, use the LS command. The service processor utility hardware on HP Superdome servers has two network connections: the customer LAN and private LAN. You can use the following list. • Customer LAN for Service Processor The customer LAN is the only LAN connection on each server. Note that stores a record of the network settings for each board. • Private LAN for HP-UX networking. At any command. • Control-] Escape the service processor connection...
nPartition Administrator's Guide, Second Edition
Page 112
... 5-8 HP-UX Booting (EFI Boot Manager) From the EFI Boot Manager menu, choose an item from the boot options list. Procedure 5-9 HP-UX Booting (EFI Shell) From the EFI Shell environment, to initiate booting using them . Each item in the boot options list references a specific boot device and provides a specific set of boot options or arguments to "ACPI Configuration for HP-UX Must Be default" (page 110) for required configuration details. 1. Access the EFI Boot Manager menu for the root device and then enter...
... 5-8 HP-UX Booting (EFI Boot Manager) From the EFI Boot Manager menu, choose an item from the boot options list. Procedure 5-9 HP-UX Booting (EFI Shell) From the EFI Shell environment, to initiate booting using them . Each item in the boot options list references a specific boot device and provides a specific set of boot options or arguments to "ACPI Configuration for HP-UX Must Be default" (page 110) for required configuration details. 1. Access the EFI Boot Manager menu for the root device and then enter...
nPartition Administrator's Guide, Second Edition
Page 209
... off . Table 7-2 lists the meanings for PCI card slot LEDs only. LEDs for Managing Hardware" (page 201). 2. Select the cell or I/O chassis you want to be turned off . 3. Exit Partition Manager. BLINKING Selected to power on or off an I/O chassis, instead use Partition Manager Version 2.0 remote administration features. 1. Turning Attention Indicators (LEDs) On and Off 209 For details on or off the selected item. If powering on accessing Partition Manager or other tools...
... off . Table 7-2 lists the meanings for PCI card slot LEDs only. LEDs for Managing Hardware" (page 201). 2. Select the cell or I/O chassis you want to be turned off . 3. Exit Partition Manager. BLINKING Selected to power on or off an I/O chassis, instead use Partition Manager Version 2.0 remote administration features. 1. Turning Attention Indicators (LEDs) On and Off 209 For details on or off the selected item. If powering on accessing Partition Manager or other tools...
nPartition Administrator's Guide, Second Edition
Page 219
...) for the nPartition. 2 The next time the nPartition is booted (after changing its Hyper-Threading status. Hyper-Threading will be enabled or disabled until after the nPartition is the nPartition number. • Using Partition Manager: Perform the Modify nPartition task and select the Enable Hyper-Threading check box on the Configure Memory tab. Checking the Hyper-Threading Status for an nPartition...
...) for the nPartition. 2 The next time the nPartition is booted (after changing its Hyper-Threading status. Hyper-Threading will be enabled or disabled until after the nPartition is the nPartition number. • Using Partition Manager: Perform the Modify nPartition task and select the Enable Hyper-Threading check box on the Configure Memory tab. Checking the Hyper-Threading Status for an nPartition...
User Guide, Third Edition - hp rp7405/rp7410 Servers
Page 120
... and Cooling Table B-6 Typical hp rp7405/rp7410 Configurations Cell Boards Memory Per Cell Board PCI Cards (assumes 10 watts each PCI card. Air Flow The hp rp7405/rp7410 servers require that typically occur at the faceplate tail of housekeeping power and + run at full speed during standby to computer rooms with existing noise sources. The PCI fans are powered off of each ) DVDs Hard Disk Drives Core I/O Bulk Power Supplies Typical Power Typical Cooling Qty 2 2 2 1 GBytes...
... and Cooling Table B-6 Typical hp rp7405/rp7410 Configurations Cell Boards Memory Per Cell Board PCI Cards (assumes 10 watts each PCI card. Air Flow The hp rp7405/rp7410 servers require that typically occur at the faceplate tail of housekeeping power and + run at full speed during standby to computer rooms with existing noise sources. The PCI fans are powered off of each ) DVDs Hard Disk Drives Core I/O Bulk Power Supplies Typical Power Typical Cooling Qty 2 2 2 1 GBytes...
User Guide, Third Edition - hp rp7405/rp7410 Servers
Page 146
... network name, 41 MP/SCSI, 4, 11, 12, 13, 15, 30, 36, 87, 88, 91 removing and replacing, 87, 88 N noise emission specifications, 98 null modem cable connectivity, 38 part number, 38 O operating environment, 97 P password MP, 39 PCI backplane, 2, 4, 11, 13, 79 PDC Processor Dependent Code, 44 PDH riser board, 9 power applying cabinet, 44 cabinet switch, 44 housekeeping, 38, 44 power considerations, 104 power cords, 95 power distribution hardware, 105 power...
... network name, 41 MP/SCSI, 4, 11, 12, 13, 15, 30, 36, 87, 88, 91 removing and replacing, 87, 88 N noise emission specifications, 98 null modem cable connectivity, 38 part number, 38 O operating environment, 97 P password MP, 39 PCI backplane, 2, 4, 11, 13, 79 PDC Processor Dependent Code, 44 PDH riser board, 9 power applying cabinet, 44 cabinet switch, 44 housekeeping, 38, 44 power considerations, 104 power cords, 95 power distribution hardware, 105 power...
User's Guide - Service Processor (GSP or MP)
Page 33
... server models based on other features. Service Processor (GSP or MP) User's Guide, rev 1.0 33 On HP Superdome servers, the customer LAN port is the connection to the Superdome service support processor (SSP) workstation, also called the service management station (SMS). It typically is not used for connections to the service processor and are given in the procedure Configuring Service Processor Network Settings on configuring service processor networking are given in the following list...
... server models based on other features. Service Processor (GSP or MP) User's Guide, rev 1.0 33 On HP Superdome servers, the customer LAN port is the connection to the Superdome service support processor (SSP) workstation, also called the service management station (SMS). It typically is not used for connections to the service processor and are given in the procedure Configuring Service Processor Network Settings on configuring service processor networking are given in the following list...