Instruction Manual - Page 3

... which, if not avoided, will result in the sections which , if not avoided, may cause machine damage. CAUTION indicates a potentially hazardous situation which contain the operation and maintenance instructions. Never use this nailer. Hazards that result from the operation and maintenance of the operating instructions, safety precautions and warnings in this Manual.
Instruction Manual - Page 4

... 8.5 kgf/cm2) Do not exceed maximum recommended air pressure 120 psi (8.3 bar 8.5 kgf/cm2). Never connect the Nailer to pressure which potentially exceeds 200 psi (13.7 bar 14 kgf/cm2) as a power source for the Nailer. English SAFETY IMPORTANT SAFETY INSTRUCTIONS MMMMFOR USING NAILERSMMlMM READ ALL INSTRUCTIONS DANGER 1. OPERATORS AND OTHERS IN WORK AREA MUST WEAR...
Instruction Manual - Page 5

... moving parts. NEVER CARRY NAILER BY HOSE. - 5 - English SAFETY - When not in a dry place. Cluttered areas invite injuries. NEVER USE NON RELIEVING COUPLER ON NAILER. CHECK PUSH LEVER BEFORE USE. KEEP ALL SCREWS AND COVERS TIGHTLY IN PLACE. Check their condition periodically. and 3) pull the trigger and release it QUICKLY when performing intermittent operation...
Instruction Manual - Page 6

... repair the Nailer. 34. USE ONLY PARTS, ACCESSORIES OR FASTENERS SUPPLIED OR RECOMMENDED BY HITACHI. Unauthorized parts, accessories, or fasteners may void your warranty and can fire when re-connected to an air supply. 27. Doing so may result. - 6 - If the Nailer appears to be left unattended since people who are not familiar with its operation or unauthorized personnel. 30. The Nailer...
Instruction Manual - Page 7

... used before repair. Keep Nailers in work area. 4. Maintain Nailers properly. 6. CLOSE NAIL GUIDE AND DO NOT OPEN IT DURING OPERATION. The fasteners can be driven away from the workpiece. 2. EMPLOYER'S RESPONSIBILITIES 1. Ensure that Nailers which can cause an explosion. Continued IMPORTANT SAFETY INSTRUCTIONS FOR USING NV45AB2 COIL NAILER WARNING 1. IMPORTANT...
Instruction Manual - Page 8

... in the safe operation of the Nailer. NAME OF PARTS Exhaust Cover Piston O-ring Piston Driver Blade Trigger Body Air Plug (Sold separately) Cap Magazine Cover Adjuster Magazine Assembly Nose Push Lever A 7/ 8" 1" 1-1/ 4" 1-1/2" 1-3/4" Section A-A A Main Nail Stopper Feeder Nail Holder Firing Head (Outlet) Shingle Guide Nail Guide Magazine Assembly Feeder Feed...
Instruction Manual - Page 9

... 3 Allen wrench for the NV45AB2/NV45AB2(S). The use only the genuine HITACHI nails for M4 screw 23 1 1 1 - 9 - Wire-collated coil nails Min. .413" (10.5mm) Max. .413" (10.5mm) 7/8"(22mm) 1-3/4"(45mm) .120" (3.05mm) .120" (3.05mm) ACCESSORIES WARNING ⅷ Accessories other nails can result in the Table below can be driven with this Nailer. Only nails shown in...
Instruction Manual - Page 10

...change without any obligation on the air hose. AIR SUPPLY DANGER ⅷ NEVER use non relieving coupler on the Nailer. - 10 - Lubricator .... Nailer Side Regulator Compressor Side Lubricator Filter 3. BEFORE OPERATION Read section titled "SAFETY" (pages 4 - 7). Use Hitachi pneumatic tool lubricant. English OPTIONAL ACCESSORIES ... Air hose Air hose must remove all pressure...
Instruction Manual - Page 11

...1 Reduce the air pressure to ANSI Z87.1 specifications. Push Lever Trigger Do not connect air hose - 11 - WARNING ⅷ Never use detergent oil or additives. LUBRICATION It is already cold, bring it in work , test the Nailer by using the Nailer and contact a Hitachi authorized service center immediately. (1) DISCONNECT AIR HOSE FROM NAILER. Do not use Nailer unless push lever...
Instruction Manual - Page 12

... pull trigger; 2) do the job. Hold the Nailer downward and pull the trigger. Ⅺ THE NAILER MUST NOT OPERATE. Nail Guide Magazine Cover (2) Adjust the position of the nail holder with a mark on the magazine in the Nailer. Ⅺ THE NAILER MUST NOT LEAK AIR. Connect the air hose. The correct air pressure is the lowest pressure which will not...
Instruction Manual - Page 13

... coil in the magazine. Magazine Opening Magazine English guide and knob, turn the nail guide clockwise while pressing the knob downward, and then close correctly. Driving Hole Guide Surface Guide... and 1" For 1-1/2" and 1-3/4" Magazine Cover Nail Guide 2 Pawl Feeder NOTE: Be careful not to deform the collated wires and not to operate. (1) Press the magazine stopper and open the magazine ...
Instruction Manual - Page 15

...: 1) disconnect air hose from the Nailer; 2) remove all warnings and instructions. ⅷ Always handle nails and package carefully. Each depression of the muzzle during fastening operation, because serious ...Remove finger from the trigger. The nailer with the following "Methods of Hitachi pneumatic tool lubricant into the air plug on the air compressor tank to you keep the trigger...
Instruction Manual - Page 17

... ⅷ Disconnect air hose and remove all nails from those on your own Nailer. Lubricate it with nippers. CAUTION ⅷ Check that differ from Nailer when: 1) doing maintenance and inspection; Sub Nail Stopper Nose Opening Feeder Shaft Feeder 4 Lubricate the feeding surfaces of frequent jam, contact a Hitachi authorized service center. This promotes smooth operation and prevents...
Instruction Manual - Page 18

... the magazine 1 DISCONNECT AIR HOSE. 2 Clean the magazine. Keep the Nailer in a warm area. ⅜ When not in use Nailer unless push lever is available from normal use . Operator troubleshooting (See page 19) 9. Service parts list A: Item No. B: Code No. Accordingly, some parts (i.e. Cleaning and removal of wear from a Hitachi authorized service center. Clean and remove...
Instruction Manual - Page 19

... normal operation, but no nail is bent. Check for replacement. Check function of lubricant into the Nailer. Piston O-ring worn or damaged? Driver blade worn? Use larger air hose. - 19 - then blow air through filter in magazine per page 17. HOW Open manual petcock. Blow clean daily. Check for assistance. If problems persist, contact a Hitachi authorized service center...

Hitachi NV45AB2S Reviews

Do you have an experience with the Hitachi NV45AB2S that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Hitachi yet.

Popular Hitachi NV45AB2S Search Terms

The following terms are frequently used to search for Hitachi NV45AB2S support:

Ask a New Question
Use the box below to post a new question about Hitachi NV45AB2S.
Manuals / Documents
Download any of our Hitachi NV45AB2S manuals for free!

We have the following 1 documents available for the Hitachi NV45AB2S:
  • Instruction Manual

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Hitachi Manuals

Find free Hitachi NV45AB2S - 7 to 1-3 Coil Roofing Nailer manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Hitachi Reviews

View thousands of Hitachi NV45AB2S - 7 to 1-3 Coil Roofing Nailer user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Hitachi customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Hitachi customer service rankings, employee comments and much more from our sister site.