User Guide
Page 3
... Flash ROM Firmware 33 ii TABLE OF CONTENTS Introduction ...1 Scanner and Accessories 2 Scanner Components 4 The PowerLink Cable 5 Labels ...6 Maintenance ...6 Installing the Scanner to the Host System RS232 MS1690-14 7 Keyboard Wedge MS1690-47 8 Stand Alone Keyboard MS1690-47 9 IBM MS1690-11 10 Full Speed USB MS1690-40 (Integrated 11 Low Speed USB MS1690-38 (Integrated 11 Stand Kits Stand Components, MLPN 46...
... Flash ROM Firmware 33 ii TABLE OF CONTENTS Introduction ...1 Scanner and Accessories 2 Scanner Components 4 The PowerLink Cable 5 Labels ...6 Maintenance ...6 Installing the Scanner to the Host System RS232 MS1690-14 7 Keyboard Wedge MS1690-47 8 Stand Alone Keyboard MS1690-47 9 IBM MS1690-11 10 Full Speed USB MS1690-40 (Integrated 11 Low Speed USB MS1690-38 (Integrated 11 Stand Kits Stand Components, MLPN 46...
User Guide
Page 5
... performance hand-held area imaging bar code scanner that instantly turns on command data transmission. Focus™ Interface MS1690 - 11 IBM 468X/469X, RS232-TXD, RXD, RTS, CTS MS1690 - 14 RS232 (TX, RX, RTS, CTS, DTR) MS1690 - 38 Low Speed USB MS1690 - 40 MS1690 - 47 Full Speed USB Keyboard Wedge, Stand-Alone Keyboard and RS232 Transmit/Receive 1 Automatic in-stand...
... performance hand-held area imaging bar code scanner that instantly turns on command data transmission. Focus™ Interface MS1690 - 11 IBM 468X/469X, RS232-TXD, RXD, RTS, CTS MS1690 - 14 RS232 (TX, RX, RTS, CTS, DTR) MS1690 - 38 Low Speed USB MS1690 - 40 MS1690 - 47 Full Speed USB Keyboard Wedge, Stand-Alone Keyboard and RS232 Transmit/Receive 1 Automatic in-stand...
User Guide
Page 6
...-Line Configuration Guide* 00-02065 Supplemental Configuration Guide* 00-02098 MS1690 Focus Area Imaging Bar Code Scanner Installation and User's Guide* * Available on the Metrologic website - Regulated 5.2VDC @ 650 mA output. 45-45593 45...Keyboard Wedge PowerLink Cable with Adapter Cable 2.7 m (9 ft.) coiled cord, long strain relief, black 53-53020-3 Stand Alone Keyboard PowerLink Cable 2.7 m (9 ft.) coiled cord, long strain relief, black Other items may be ordered for the specific protocol being used. To order additional items, contact the dealer, distributor or call Metrologic...
...-Line Configuration Guide* 00-02065 Supplemental Configuration Guide* 00-02098 MS1690 Focus Area Imaging Bar Code Scanner Installation and User's Guide* * Available on the Metrologic website - Regulated 5.2VDC @ 650 mA output. 45-45593 45...Keyboard Wedge PowerLink Cable with Adapter Cable 2.7 m (9 ft.) coiled cord, long strain relief, black 53-53020-3 Stand Alone Keyboard PowerLink Cable 2.7 m (9 ft.) coiled cord, long strain relief, black Other items may be ordered for the specific protocol being used. To order additional items, contact the dealer, distributor or call Metrologic...
User Guide
Page 12
...(Safety Extra Low Voltage) according to the host system. Focus will be easily accessible. In addition, please check that scanned information will start to the keyboard and keyboard port on changing the scanner's configuration. You will hear a 'click' when the ...Keyboard Wedge MS1690-47 1. Plug the external power supply (required) into a port on the host device. When the scanner has finished initializing the LEDs will stop flashing and the unit will light for instructions on the host device. The scanner is made. 3. Plugging the scanner into the power jack on the Focus...
...(Safety Extra Low Voltage) according to the host system. Focus will be easily accessible. In addition, please check that scanned information will start to the keyboard and keyboard port on changing the scanner's configuration. You will hear a 'click' when the ...Keyboard Wedge MS1690-47 1. Plug the external power supply (required) into a port on the host device. When the scanner has finished initializing the LEDs will stop flashing and the unit will light for instructions on the host device. The scanner is made. 3. Plugging the scanner into the power jack on the Focus...
User Guide
Page 29
BMP, TIFF, or JPEG output System Interfaces: PC Keyboard Wedge, RS232, IBM 468X/469X, Stand Alone Keyboard, USB (Low Speed and Full Speed) Print Contrast: 20% Minimum Reflectance Difference Number Characters Read: Up to 80 Data Characters on 1D; ... - 30 mm (1.2") Width: Head - 79 mm (3.1") Depth: 111 mm (4.9") Weight: 225 g (8.0 oz) Termination: 10 pin modular RJ45 Cable: Standard 2.7 m (9') Coiled; DESIGN SPECIFICATIONS OPERATIONAL MS1690 DESIGN SPECIFICATIONS Light Source: LED 645 nm Pulse Duration: Maximum Output of an Osram LED: 1 ms to 8 ms Maximum 85 mA emits 3,120 mlm Depth...
BMP, TIFF, or JPEG output System Interfaces: PC Keyboard Wedge, RS232, IBM 468X/469X, Stand Alone Keyboard, USB (Low Speed and Full Speed) Print Contrast: 20% Minimum Reflectance Difference Number Characters Read: Up to 80 Data Characters on 1D; ... - 30 mm (1.2") Width: Head - 79 mm (3.1") Depth: 111 mm (4.9") Weight: 225 g (8.0 oz) Termination: 10 pin modular RJ45 Cable: Standard 2.7 m (9') Coiled; DESIGN SPECIFICATIONS OPERATIONAL MS1690 DESIGN SPECIFICATIONS Light Source: LED 645 nm Pulse Duration: Maximum Output of an Osram LED: 1 ms to 8 ms Maximum 85 mA emits 3,120 mlm Depth...
User Guide
Page 31
... to pages 28-31. For information on how to change the default settings, refer to the keyboard wedge. The following are the most important selectable options specific to help files in other Metrologic scanners are also available as keyboard wedge functions. SCANNER MS1690 - VERSION IDENTIFIER 11 COMMUNICATION PROTOCOL(S) IBM 468X/469X, RS232-TXD, RXD, RTS, CTS 14 RS232...
... to pages 28-31. For information on how to change the default settings, refer to the keyboard wedge. The following are the most important selectable options specific to help files in other Metrologic scanners are also available as keyboard wedge functions. SCANNER MS1690 - VERSION IDENTIFIER 11 COMMUNICATION PROTOCOL(S) IBM 468X/469X, RS232-TXD, RXD, RTS, CTS 14 RS232...
User Guide
Page 37
...scanners. To upgrade all RS232 (-14), keyboard wedge (-47), IBM 468X/469X (-11), low speed USB (-38), and full speed USB (-40) units can follow the progress of the upgrade by watching the screen for additional assistance. 33 UPGRADING THE FLASH ROM FIRMWARE The MetroSet2 program is a functional component of Metrologic...to upgrade the scanner. Once the file is selected and verified, the scanner is ready to a new or custom version of the version number or communication protocol, can be upgraded. Contact a Metrologic service representative for details. Each MS1690, regardless of ...
...scanners. To upgrade all RS232 (-14), keyboard wedge (-47), IBM 468X/469X (-11), low speed USB (-38), and full speed USB (-40) units can follow the progress of the upgrade by watching the screen for additional assistance. 33 UPGRADING THE FLASH ROM FIRMWARE The MetroSet2 program is a functional component of Metrologic...to upgrade the scanner. Once the file is selected and verified, the scanner is ready to a new or custom version of the version number or communication protocol, can be upgraded. Contact a Metrologic service representative for details. Each MS1690, regardless of ...
User Guide
Page 38
... Socket. The serial # label indicates the interface enabled when the scanner is shipped from the factory. MS1690-14, RS232 Pin Function 1 Ground 2 RS232 Transmit Output 3 RS232 Receive Input 4 RTS Output 5 CTS Input 6 DTR Input 7 Reserved 8 Reserved 9 +5VDC 10 Shield Ground MS1690-47, Keyboard Wedge & Stand-Alone Keyboard Pin Function 1 Ground 2 RS232 Transmit Output 3 RS232 Receive Input...
... Socket. The serial # label indicates the interface enabled when the scanner is shipped from the factory. MS1690-14, RS232 Pin Function 1 Ground 2 RS232 Transmit Output 3 RS232 Receive Input 4 RTS Output 5 CTS Input 6 DTR Input 7 Reserved 8 Reserved 9 +5VDC 10 Shield Ground MS1690-47, Keyboard Wedge & Stand-Alone Keyboard Pin Function 1 Ground 2 RS232 Transmit Output 3 RS232 Receive Input...
User Guide
Page 41
... the keyboard and the keyboard port on the other. SCANNER AND CABLE TERMINATIONS Cable Connector Configuration (Host End) Keyboard Wedge PowerLink Cable 53-53002-3 Coiled Pin Function 1 Keyboard Clock 2 Keyboard Data 3 No Connect 4 Power Ground 5 +5 VDC Pin Function 1 PC Data 2 No Connect 3 Power Ground 4 +5 VDC 5 PC Clock 6 No Connect 2 4 5 1 3 5-Pin DIN, Female 2 1 4 3 65 6-Pin DIN, Male Metrologic will...
... the keyboard and the keyboard port on the other. SCANNER AND CABLE TERMINATIONS Cable Connector Configuration (Host End) Keyboard Wedge PowerLink Cable 53-53002-3 Coiled Pin Function 1 Keyboard Clock 2 Keyboard Data 3 No Connect 4 Power Ground 5 +5 VDC Pin Function 1 PC Data 2 No Connect 3 Power Ground 4 +5 VDC 5 PC Clock 6 No Connect 2 4 5 1 3 5-Pin DIN, Female 2 1 4 3 65 6-Pin DIN, Male Metrologic will...
User Guide
Page 46
...19 Beep 17-18, 21-24, 25, 33 Blue LED........... 4, 7-11, 17-18, 33 C Cable 3 IBM 10 Keyboard Wedge ...........8, 36-37 MVC 3 PowerLink....... 2, 5, 7-11, 21-24, 33, 36-37 RS232 7, 36-37 Stand Alone Keyboard ...9, 36-37 USB 11, 36-37 Caution 7-11, 39-40 CE 6, 7-11, 40 Class 39 CodeGate 1, 4, ...Current 26 Customer Service 2, 3, 38 D DC 2, 26, 34-35, 36-37 Decode 25 Default Parameters ..........27, 28-31 IBM 28-31 Keyboard Wedge 28-31 RS232 28-31 Stand Alone Keyboard .......28-31 USB 28-31 42 Depth of Field 19 E EMC 26 F Firmware 33 Flash ROM 33 H Host 5, 7-11 I Indicator ...
...19 Beep 17-18, 21-24, 25, 33 Blue LED........... 4, 7-11, 17-18, 33 C Cable 3 IBM 10 Keyboard Wedge ...........8, 36-37 MVC 3 PowerLink....... 2, 5, 7-11, 21-24, 33, 36-37 RS232 7, 36-37 Stand Alone Keyboard ...9, 36-37 USB 11, 36-37 Caution 7-11, 39-40 CE 6, 7-11, 40 Class 39 CodeGate 1, 4, ...Current 26 Customer Service 2, 3, 38 D DC 2, 26, 34-35, 36-37 Decode 25 Default Parameters ..........27, 28-31 IBM 28-31 Keyboard Wedge 28-31 RS232 28-31 Stand Alone Keyboard .......28-31 USB 28-31 42 Depth of Field 19 E EMC 26 F Firmware 33 Flash ROM 33 H Host 5, 7-11 I Indicator ...