User Guide
Page 3
...Introduction ...1 Scanner and Accessories 2 Scanner Components 4 The PowerLink Cable 5 Labels ...6 Maintenance ...6 Installing the Scanner to the Host System RS232 MS1690-14 7 Keyboard Wedge MS1690-47 8 Stand Alone Keyboard MS1690-47 9 IBM MS1690-11 10 Full Speed USB MS1690-40 (Integrated 11 Low Speed USB MS1690-38 (Integrated...Stand 14 Scanner Operation Two Default Modes of Operation 15 Audible Indicators 16 Visual Indicators 17 Failure Modes 18 Depth of Field by Minimum Bar Code Element Width 19 IR Activation Range 20 Troubleshooting Guide 21 Design Specifications 25 ...
...Introduction ...1 Scanner and Accessories 2 Scanner Components 4 The PowerLink Cable 5 Labels ...6 Maintenance ...6 Installing the Scanner to the Host System RS232 MS1690-14 7 Keyboard Wedge MS1690-47 8 Stand Alone Keyboard MS1690-47 9 IBM MS1690-11 10 Full Speed USB MS1690-40 (Integrated 11 Low Speed USB MS1690-38 (Integrated...Stand 14 Scanner Operation Two Default Modes of Operation 15 Audible Indicators 16 Visual Indicators 17 Failure Modes 18 Depth of Field by Minimum Bar Code Element Width 19 IR Activation Range 20 Troubleshooting Guide 21 Design Specifications 25 ...
User Guide
Page 6
... ACCESSORIES Description AC to DC Power Transformer - To order additional items, contact the dealer, distributor or call Metrologic's Customer Service Department at 1-800-ID-METRO or 1-800-436-3876. 2 Regulated 5.2VDC @ 650 mA...specific protocol being used. INTRODUCTION Scanner and Accessories Part # BASIC KIT Description MS1690 00-02544 Focus Area Imaging Bar Code Scanner MetroSelect® Single-Line Configuration Guide* 00-02065 Supplemental Configuration Guide* 00-02098 MS1690 Focus Area Imaging Bar Code Scanner Installation and User's Guide* * Available on the Metrologic...
... ACCESSORIES Description AC to DC Power Transformer - To order additional items, contact the dealer, distributor or call Metrologic's Customer Service Department at 1-800-ID-METRO or 1-800-436-3876. 2 Regulated 5.2VDC @ 650 mA...specific protocol being used. INTRODUCTION Scanner and Accessories Part # BASIC KIT Description MS1690 00-02544 Focus Area Imaging Bar Code Scanner MetroSelect® Single-Line Configuration Guide* 00-02065 Supplemental Configuration Guide* 00-02098 MS1690 Focus Area Imaging Bar Code Scanner Installation and User's Guide* * Available on the Metrologic...
User Guide
Page 7
...To order additional items, contact the dealer, distributor or call Metrologic's Customer Service Department at 1-800-ID-METRO or 1-800-436-3876. 3 INTRODUCTION Scanner and Accessories Part # OPTIONAL ACCESSORIES Description 53-53213x-N-3 USB ...Metrologic Voltage Converter (MVC) Cable* ±12VDC to +5.2VDC * Contact a Metrologic customer service representative for additional information on the MVC cable series and the host connections available. 00-02001 MS1690 Focus Stand (46-00147) Installation Guide 46-00147 Modular Presentation Stand Other items may be ordered for the specific...
...To order additional items, contact the dealer, distributor or call Metrologic's Customer Service Department at 1-800-ID-METRO or 1-800-436-3876. 3 INTRODUCTION Scanner and Accessories Part # OPTIONAL ACCESSORIES Description 53-53213x-N-3 USB ...Metrologic Voltage Converter (MVC) Cable* ±12VDC to +5.2VDC * Contact a Metrologic customer service representative for additional information on the MVC cable series and the host connections available. 00-02001 MS1690 Focus Stand (46-00147) Installation Guide 46-00147 Modular Presentation Stand Other items may be ordered for the specific...
User Guide
Page 23
SCANNER OPERATION Depth of Field by Minimum Bar Code Element Width Figure 16. Depth of Field by Minimum Bar Code Element Width A mm .132 mils 5.2 MINIMUM BAR CODE ELEMENT WIDTH 1D PDF B C D E F G .19 .254 .33 .533 .254 .381 7.5 10.4 13 21 10 15.9 Specifications are subject to change without notice. 19
SCANNER OPERATION Depth of Field by Minimum Bar Code Element Width Figure 16. Depth of Field by Minimum Bar Code Element Width A mm .132 mils 5.2 MINIMUM BAR CODE ELEMENT WIDTH 1D PDF B C D E F G .19 .254 .33 .533 .254 .381 7.5 10.4 13 21 10 15.9 Specifications are subject to change without notice. 19
User Guide
Page 24
IR Activation Area Specifications are subject to change without notice. 20 SCANNER OPERATION IR Activation Range The MS1690 has a built in object detection sensor that instantly turns on the scanner when an object is presented within the scanner's IR activation Area. Figure 17.
IR Activation Area Specifications are subject to change without notice. 20 SCANNER OPERATION IR Activation Range The MS1690 has a built in object detection sensor that instantly turns on the scanner when an object is presented within the scanner's IR activation Area. Figure 17.
User Guide
Page 29
Optional 2.1 m (7') Straight Specifications are subject to change without notice. 25 BMP, TIFF, or JPEG output System Interfaces: PC Keyboard Wedge, RS232, IBM 468X/469X, Stand Alone Keyboard, USB (...: 183 mm (7.2") Handle - 30 mm (1.2") Width: Head - 79 mm (3.1") Depth: 111 mm (4.9") Weight: 225 g (8.0 oz) Termination: 10 pin modular RJ45 Cable: Standard 2.7 m (9') Coiled; DESIGN SPECIFICATIONS OPERATIONAL MS1690 DESIGN SPECIFICATIONS Light Source: LED 645 nm Pulse Duration: Maximum Output of an Osram LED: 1 ms to 8 ms Maximum 85 mA emits 3,120 mlm Depth of...
Optional 2.1 m (7') Straight Specifications are subject to change without notice. 25 BMP, TIFF, or JPEG output System Interfaces: PC Keyboard Wedge, RS232, IBM 468X/469X, Stand Alone Keyboard, USB (...: 183 mm (7.2") Handle - 30 mm (1.2") Width: Head - 79 mm (3.1") Depth: 111 mm (4.9") Weight: 225 g (8.0 oz) Termination: 10 pin modular RJ45 Cable: Standard 2.7 m (9') Coiled; DESIGN SPECIFICATIONS OPERATIONAL MS1690 DESIGN SPECIFICATIONS Light Source: LED 645 nm Pulse Duration: Maximum Output of an Osram LED: 1 ms to 8 ms Maximum 85 mA emits 3,120 mlm Depth of...
User Guide
Page 30
DESIGN SPECIFICATIONS ELECTRICAL MS1690 DESIGN SPECIFICATIONS Input Voltage: 5.0VDC ± 0.25V Peak = 2 W (Typical) Power: Operating = 1.65 W (Typical) Idle / Standby = 800 mW (Typical) Peak = 400 mA (Typical) Current: Operation = 330 mA (Typical) ..., Non-Condensing Light Levels: Up to 4842 Lux (450 Footcandles) Shock: Designed to withstand 1.8 m (6') drops Contaminants: Sealed to resist airborne particulate contaminants Ventilation: None required Specifications are subject to change without notice.. 26
DESIGN SPECIFICATIONS ELECTRICAL MS1690 DESIGN SPECIFICATIONS Input Voltage: 5.0VDC ± 0.25V Peak = 2 W (Typical) Power: Operating = 1.65 W (Typical) Idle / Standby = 800 mW (Typical) Peak = 400 mA (Typical) Current: Operation = 330 mA (Typical) ..., Non-Condensing Light Levels: Up to 4842 Lux (450 Footcandles) Shock: Designed to withstand 1.8 m (6') drops Contaminants: Sealed to resist airborne particulate contaminants Ventilation: None required Specifications are subject to change without notice.. 26
User Guide
Page 31
... as keyboard wedge functions. For information on how to change the default settings, refer to pages 28-31. SCANNER MS1690 - Many RS232 configurable functions available in other Metrologic scanners are the most important selectable options specific to the keyboard wedge. APPLICATIONS AND PROTOCOLS The model number on the MS 1690's default settings refer to help...
... as keyboard wedge functions. For information on how to change the default settings, refer to pages 28-31. SCANNER MS1690 - Many RS232 configurable functions available in other Metrologic scanners are the most important selectable options specific to the keyboard wedge. APPLICATIONS AND PROTOCOLS The model number on the MS 1690's default settings refer to help...
User Guide
Page 42
... from the date of manufacture. facility. The MS1690 Focus scanners have been produced and labeled in the sole judgment of Product is void if the case of Metrologic, has been subjected to one of Metrologic. Madrid, Spain; To do this warranty, Metrologic shall, at its sole option, repair the ...THIS LIMITED WARRANTY, EXCEPT AS TO TITLE, IS IN LIEU OF ALL OTHER WARRANTIES OR GUARANTEES, EITHER EXPRESS OR IMPLIED, AND SPECIFICALLY EXCLUDES, WITHOUT LIMITATION, WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE UNDER THE UNIFORM COMMERCIAL CODE, OR ARISING OUT OF CUSTOM OR...
... from the date of manufacture. facility. The MS1690 Focus scanners have been produced and labeled in the sole judgment of Product is void if the case of Metrologic, has been subjected to one of Metrologic. Madrid, Spain; To do this warranty, Metrologic shall, at its sole option, repair the ...THIS LIMITED WARRANTY, EXCEPT AS TO TITLE, IS IN LIEU OF ALL OTHER WARRANTIES OR GUARANTEES, EITHER EXPRESS OR IMPLIED, AND SPECIFICALLY EXCLUDES, WITHOUT LIMITATION, WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE UNDER THE UNIFORM COMMERCIAL CODE, OR ARISING OUT OF CUSTOM OR...
User Guide
Page 47
... Supply 5, 7-11 PowerLink 4 Presentation 15 Product Safety 39-40 Protocols 27 R Razz 17-18, 21-24 Repair 38 RMA 38 RS232 2 S SELV 7-11 Service 38 Specifications Electrical 26 Environmental 26 Mechanical 25 Operational 25 Stand 3, 12-14, 15 Stand Alone Keyboard 2 Swiftdecoder 1 T Tone 17-18 Alternate 16 Transformer 2, 7-11, 26 Trigger...
... Supply 5, 7-11 PowerLink 4 Presentation 15 Product Safety 39-40 Protocols 27 R Razz 17-18, 21-24 Repair 38 RMA 38 RS232 2 S SELV 7-11 Service 38 Specifications Electrical 26 Environmental 26 Mechanical 25 Operational 25 Stand 3, 12-14, 15 Stand Alone Keyboard 2 Swiftdecoder 1 T Tone 17-18 Alternate 16 Transformer 2, 7-11, 26 Trigger...