User Guide
Page 5
...MetroSet®2 Windows® compatible software • Support for scanning. INTRODUCTION Product Overview Metrologic's MS9520 Voyager® and the MS9540 VoyagerCG® are a group of single-line laser bar code scanners that have the ability...8226; Sunrise 2005 compliant The MS9540 includes Metrologic's patented auto-trigger and CodeGate button feature. VOYAGER MS9520 - 00 MS9520 - 9 MS9520 - 11 MS9520 - 14 MS9520 - 38 MS9520 - 40 MS9520 - 41 MS9520 - 47 VOYAGERCG MS9540 - 00 MS9540 - 9 MS9540 - 11 MS9540 - 14 MS9540 - 38 MS9540 - 40 MS9540 - 41 MS9540 - 47 INTERFACE Laser Emulation ...
...MetroSet®2 Windows® compatible software • Support for scanning. INTRODUCTION Product Overview Metrologic's MS9520 Voyager® and the MS9540 VoyagerCG® are a group of single-line laser bar code scanners that have the ability...8226; Sunrise 2005 compliant The MS9540 includes Metrologic's patented auto-trigger and CodeGate button feature. VOYAGER MS9520 - 00 MS9520 - 9 MS9520 - 11 MS9520 - 14 MS9520 - 38 MS9520 - 40 MS9520 - 41 MS9520 - 47 VOYAGERCG MS9540 - 00 MS9540 - 9 MS9540 - 11 MS9540 - 14 MS9540 - 38 MS9540 - 40 MS9540 - 41 MS9540 - 47 INTERFACE Laser Emulation ...
User Guide
Page 27
... protocol, can be used in files called Motorola S-record files. In other words, all RS232 (-41), keyboard wedge (-47), light pen (-41), laser emulation (-00), OCIA (-9), IBM 468X/469X (-11), low speed USB (-38), and full speed USB (-40) units can be upgraded. These files contain all units, a ... is complete, the scanner will be on power up. UPGRADING THE FLASH ROM FIRMWARE The MetroSet2 program is a functional component of Metrologic's new line of software. The program guides the user with its simplistic one beep on . The user must first select the file; Contact...
... protocol, can be used in files called Motorola S-record files. In other words, all RS232 (-41), keyboard wedge (-47), light pen (-41), laser emulation (-00), OCIA (-9), IBM 468X/469X (-11), low speed USB (-38), and full speed USB (-40) units can be upgraded. These files contain all units, a ... is complete, the scanner will be on power up. UPGRADING THE FLASH ROM FIRMWARE The MetroSet2 program is a functional component of Metrologic's new line of software. The program guides the user with its simplistic one beep on . The user must first select the file; Contact...
User Guide
Page 30
Many RS232 configurable functions available in other Metrologic scanners are the most important selectable options specific to keyboard...Identifier Communication Protocol(s) 00 Laser Emulation and RS232 Transmit/Receive 9 OCIA and RS232 Transmit/Receive MS9520 Or MS9540 11 IBM 468X/469X, RS232 - Refer to the MetroSelect Single-Line Configuration Guide (MLPN 00-02544)...additional information). TXD, RXD, RTS, CTS, DTR, DSR 38 Low Speed USB, Serial Emulation or Keyboard Emulation 40 Full Speed Integrated USB 41 RS232/Light Pen Emulation 47 Keyboard Wedge, Stand-Alone Keyboard...
Many RS232 configurable functions available in other Metrologic scanners are the most important selectable options specific to keyboard...Identifier Communication Protocol(s) 00 Laser Emulation and RS232 Transmit/Receive 9 OCIA and RS232 Transmit/Receive MS9520 Or MS9540 11 IBM 468X/469X, RS232 - Refer to the MetroSelect Single-Line Configuration Guide (MLPN 00-02544)...additional information). TXD, RXD, RTS, CTS, DTR, DSR 38 Low Speed USB, Serial Emulation or Keyboard Emulation 40 Full Speed Integrated USB 41 RS232/Light Pen Emulation 47 Keyboard Wedge, Stand-Alone Keyboard...
User Guide
Page 42
SCANNER AND CABLE TERMINATIONS Scanner Pinout Connections The MS9520 and MS9540 scanner interfaces terminate to a 10-pin modular jack. MS95x0-41 RS232 and Light Pen Emulation Pin Function 1 Ground 2 RS232 Transmit Output 3 RS232 Receive Input 4 RTS Output 5 CTS Input 6 DTR Input/LTPN Source 7 Reserved 8 LTPN ... Function 1 Ground 2 RS232 Transmit Output 3 RS232 Receive Input 4 RTS Output 5 CTS Input 6 DTR Input 7 IBM B-Transmit 8 IBM A+ Receive 9 +5VDC 10 Shield Ground 38 The serial # label indicates the interface enabled when the scanner is shipped from the factory.
SCANNER AND CABLE TERMINATIONS Scanner Pinout Connections The MS9520 and MS9540 scanner interfaces terminate to a 10-pin modular jack. MS95x0-41 RS232 and Light Pen Emulation Pin Function 1 Ground 2 RS232 Transmit Output 3 RS232 Receive Input 4 RTS Output 5 CTS Input 6 DTR Input/LTPN Source 7 Reserved 8 LTPN ... Function 1 Ground 2 RS232 Transmit Output 3 RS232 Receive Input 4 RTS Output 5 CTS Input 6 DTR Input 7 IBM B-Transmit 8 IBM A+ Receive 9 +5VDC 10 Shield Ground 38 The serial # label indicates the interface enabled when the scanner is shipped from the factory.
User Guide
Page 45
SCANNER AND CABLE TERMINATIONS Cable Connector Configurations (Host End) USB Cables MLPN 53-53213x-N-3, 53-53214x-N-3 or 53-53235x-N-3 Pin Function 1 PC +5V/V_USB 2 D- 3 D+ 4 Ground Shield Shield Locking Type A Non-Locking Type A Stand-Alone Keyboard PowerLink Cable MLPN 53-53020x-3 Pin Function 1 PC Data 2 NC 3 Power Ground 4 +5VDC PC Power to KB 5 PC Clock 6 NC 6-Pin Male Mini-DIN Connector 41
SCANNER AND CABLE TERMINATIONS Cable Connector Configurations (Host End) USB Cables MLPN 53-53213x-N-3, 53-53214x-N-3 or 53-53235x-N-3 Pin Function 1 PC +5V/V_USB 2 D- 3 D+ 4 Ground Shield Shield Locking Type A Non-Locking Type A Stand-Alone Keyboard PowerLink Cable MLPN 53-53020x-3 Pin Function 1 PC Data 2 NC 3 Power Ground 4 +5VDC PC Power to KB 5 PC Clock 6 NC 6-Pin Male Mini-DIN Connector 41
Configuration Guide
Page 85
HEX Value 3C 3D 3E 3F 40 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4E 4F 50 51 52 53 54 55 56 57 58 59 Decimal Value/ Code Byte Value 060 061 062 063 064 065 066 067 068 069 070 071 072 073 074 075 076 077 078 079 080 081 082 083 084 085 086 087 088 089 Character < = > ? @ A B C D E F G H I J K L M N O P Q R S T U V W X Y Control Keyboard Eqv less than greater than shift P letter l letter O 16-5
HEX Value 3C 3D 3E 3F 40 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4E 4F 50 51 52 53 54 55 56 57 58 59 Decimal Value/ Code Byte Value 060 061 062 063 064 065 066 067 068 069 070 071 072 073 074 075 076 077 078 079 080 081 082 083 084 085 086 087 088 089 Character < = > ? @ A B C D E F G H I J K L M N O P Q R S T U V W X Y Control Keyboard Eqv less than greater than shift P letter l letter O 16-5