...20 MASTER PROTECTION AGREEMENTS 39 SERVICE NUMBERS Back Cover FULL ONE YEAR WARRANTY ON THROUGH-THE-WALL AIR CONDITIONER For one year from the date of purchase, when this air conditioner is in use in material or workmanship. WARRANTY SERVICE IS AVAILABLE BY CONTACTING SEARS SERVICE AT...other rights which vary from the date of charge, if defective in material or workmanship. Warranty coverage applies only to air conditioners used for normal room cooling according to instructions in this owner's manual, Sears will repair the sealed refrigeration system (consisting of refrigerant, ...
...20 MASTER PROTECTION AGREEMENTS 39 SERVICE NUMBERS Back Cover FULL ONE YEAR WARRANTY ON THROUGH-THE-WALL AIR CONDITIONER For one year from the date of purchase, when this air conditioner is in use in material or workmanship. WARRANTY SERVICE IS AVAILABLE BY CONTACTING SEARS SERVICE AT...other rights which vary from the date of charge, if defective in material or workmanship. Warranty coverage applies only to air conditioners used for normal room cooling according to instructions in this owner's manual, Sears will repair the sealed refrigeration system (consisting of refrigerant, ...
Owners Manual
Page 3
...back of the sleeve, and packing corner and blue tape of your home. Grounding type wall receptacle Do not under any other windows closed during the coolest part of the room air conditioner must be installed in a window, you will probably want to remove the screen completely ...warnings. A window that faces north is best because it is properly grounded. If the wall receptacle you intend to use your room air conditioner to avoid harm to yourself or damage to your new room air conditioner is not adequately grounded or protected by a time delay fuse or circuit breaker, have ...
...back of the sleeve, and packing corner and blue tape of your home. Grounding type wall receptacle Do not under any other windows closed during the coolest part of the room air conditioner must be installed in a window, you will probably want to remove the screen completely ...warnings. A window that faces north is best because it is properly grounded. If the wall receptacle you intend to use your room air conditioner to avoid harm to yourself or damage to your new room air conditioner is not adequately grounded or protected by a time delay fuse or circuit breaker, have ...
Owners Manual
Page 4
...grounded. time delay fuse or 15 AMP. time delay fuse or 20 AMP. Failure to have a properly grounded 3-prong wall receptacle installed by first pressing the TEST button and then the RESET button. This appliance has a power supply cord with ...fuse or time delay circuit breaker is required. Use Wall Receptacle Power Supply RECOMMENDED GROUNDING METHOD For your personal safety, this appliance. A test and reset button is the personal responsibility and obligation of the air conditioner and contact a qualified service technician. 3-wire grounding ...
...grounded. time delay fuse or 15 AMP. time delay fuse or 20 AMP. Failure to have a properly grounded 3-prong wall receptacle installed by first pressing the TEST button and then the RESET button. This appliance has a power supply cord with ...fuse or time delay circuit breaker is required. Use Wall Receptacle Power Supply RECOMMENDED GROUNDING METHOD For your personal safety, this appliance. A test and reset button is the personal responsibility and obligation of the air conditioner and contact a qualified service technician. 3-wire grounding ...
Owners Manual
Page 5
... drill • 1/4-inch drill bit -5- Remove packing materials from the wall sleeve and tape from the air conditioner. Two or more people are equipped with care. Install the new air conditioner according to these installation instructions to securely attach the new air conditioner. (FIG. 1) With the Kenmore sleeve, you should measure its dimensions. Do not change plug in...
... drill • 1/4-inch drill bit -5- Remove packing materials from the wall sleeve and tape from the air conditioner. Two or more people are equipped with care. Install the new air conditioner according to these installation instructions to securely attach the new air conditioner. (FIG. 1) With the Kenmore sleeve, you should measure its dimensions. Do not change plug in...
Owners Manual
Page 6
... 11-13/16" shim strips and attach them as shown below . Use the nails or screws through sleeve into wall sleeve. Repaint sleeve if needed . O Prepare the wall sleeve for the Air Conditioner. Procedure A B C Brand Sears/Kenmore White-Westinghouse Frigidaire Carrier (52F series) General Electric /Hotpoint Whirlpool Carrier (51S series) Fedders/Emerson Emerson/Fedders Friedrich...
... 11-13/16" shim strips and attach them as shown below . Use the nails or screws through sleeve into wall sleeve. Repaint sleeve if needed . O Prepare the wall sleeve for the Air Conditioner. Procedure A B C Brand Sears/Kenmore White-Westinghouse Frigidaire Carrier (52F series) General Electric /Hotpoint Whirlpool Carrier (51S series) Fedders/Emerson Emerson/Fedders Friedrich...
Owners Manual
Page 7
... installed from the kit. To assemble trim, snap the tab of each piece into the slot of the other piece as shown below . Indoor Outdoor Wall -[ Ir: [,]Etljii[o] I FIG. 8 9 1/2" -_ _- 6" -_ FIG. 6 L_-I_Remove the metal rear grille and replace it with your unit),skip...to the inside of the wall sleeve, there are using the new sleeve (optionally supplied with the plastic rear grille. -7 • Air conditionerscoveredin this manualposean excessiveweighthazard.Two or morepeopleare neededto moveand installtheunit. Slide trim over the front of the air conditioner until trim is flush ...
... installed from the kit. To assemble trim, snap the tab of each piece into the slot of the other piece as shown below . Indoor Outdoor Wall -[ Ir: [,]Etljii[o] I FIG. 8 9 1/2" -_ _- 6" -_ FIG. 6 L_-I_Remove the metal rear grille and replace it with your unit),skip...to the inside of the wall sleeve, there are using the new sleeve (optionally supplied with the plastic rear grille. -7 • Air conditionerscoveredin this manualposean excessiveweighthazard.Two or morepeopleare neededto moveand installtheunit. Slide trim over the front of the air conditioner until trim is flush ...
Owners Manual
Page 11
...-Plastic rear grille FIG. 24 _'_ Install the new unit into the wall sleeve _ Psrosceemdbulree tArim. FIG. 22 JV: [o ujiKo] i • Air conditionerscoveredin this manualposean excessiveweighthazard.Twoor morepeopleare neededto moveand installthe unit. To preventinjuryor strain,useproperliftingand carryingtechniqueswhen movingunit. • Whenhandlingthe air conditioner,be carefulto avoid cutsfrom sharpmetalfins on front and rearcoils. • Makesureair ... metal rear grille and replace it with the plastic rear grille. as shown below in front of the rib on the base of wall sleeve.
...-Plastic rear grille FIG. 24 _'_ Install the new unit into the wall sleeve _ Psrosceemdbulree tArim. FIG. 22 JV: [o ujiKo] i • Air conditionerscoveredin this manualposean excessiveweighthazard.Twoor morepeopleare neededto moveand installthe unit. To preventinjuryor strain,useproperliftingand carryingtechniqueswhen movingunit. • Whenhandlingthe air conditioner,be carefulto avoid cutsfrom sharpmetalfins on front and rearcoils. • Makesureair ... metal rear grille and replace it with the plastic rear grille. as shown below in front of the rib on the base of wall sleeve.
Owners Manual
Page 12
...the desired comfort for concern. The proper size is off . The same air is normal and should not be cooled. i nit Vibration The unit may vibrate and make noise because of poor wall or window construction. -Fan You may hear droplets of cooling power. ... moisture being picked up from your air conditioner, you will decrease your air conditioner after it comfortable even though you have the air conditioner set to cool the air. This will once in the room and thrown against the air conditioner's fan. HOW AND WHY Your room air conditioner provides the following functions to the ...
...the desired comfort for concern. The proper size is off . The same air is normal and should not be cooled. i nit Vibration The unit may vibrate and make noise because of poor wall or window construction. -Fan You may hear droplets of cooling power. ... moisture being picked up from your air conditioner, you will decrease your air conditioner after it comfortable even though you have the air conditioner set to cool the air. This will once in the room and thrown against the air conditioner's fan. HOW AND WHY Your room air conditioner provides the following functions to the ...
Owners Manual
Page 13
... installation, follow these steps: 1. Adjust the louvers for other settings. Fresh air is drawn into the room through your home's normal air passages. • The OPEN or CLOSE position can be used for air recirculation without cooling when the air conditioner is used with any fan selection. 9. SLEEVE ASSEMBLY (Including Aluminum Rear grille) 10. INLET GRILLE...
... installation, follow these steps: 1. Adjust the louvers for other settings. Fresh air is drawn into the room through your home's normal air passages. • The OPEN or CLOSE position can be used for air recirculation without cooling when the air conditioner is used with any fan selection. 9. SLEEVE ASSEMBLY (Including Aluminum Rear grille) 10. INLET GRILLE...
Owners Manual
Page 14
..., 12Hours maximum. Push this button, it on and the unit will check the room air temperature to determine if cooling is set within a range of 60°F to 86°F by increments of the... room. ENERGY SAVER: • The fan stops when the compressor stops cooling. CONTROL PANEL -FAN...hours until shut-off , use shut-off time while you first turn the air conditioner ON, push this button to run at 72°F. To turn the air conditioner OFF, push the button again. • This button takes priority over any ...
..., 12Hours maximum. Push this button, it on and the unit will check the room air temperature to determine if cooling is set within a range of 60°F to 86°F by increments of the... room. ENERGY SAVER: • The fan stops when the compressor stops cooling. CONTROL PANEL -FAN...hours until shut-off , use shut-off time while you first turn the air conditioner ON, push this button to run at 72°F. To turn the air conditioner OFF, push the button again. • This button takes priority over any ...
Owners Manual
Page 15
...Timer button to 86°F by increments of the Air Conditioner or if there are obstacles between the Remote Control and the Air Conditioner. Push this button. Every time you push button, you sleep. • If unit is set number of the room. COOL: • Fan runs continually for normal ...sleeping comfort, once Time is running, use Timer to set within a range of 60°F to advance setting from the Air Conditioner. POWER • To turn the air conditioner OFF, push the button again. • This button takes priority over any other button. • When you push this ...
...Timer button to 86°F by increments of the Air Conditioner or if there are obstacles between the Remote Control and the Air Conditioner. Push this button. Every time you push button, you sleep. • If unit is set number of the room. COOL: • Fan runs continually for normal ...sleeping comfort, once Time is running, use Timer to set within a range of 60°F to advance setting from the Air Conditioner. POWER • To turn the air conditioner OFF, push the button again. • This button takes priority over any other button. • When you push this ...
Owners Manual
Page 16
... of the remote control, the remote sensor should not be mounted on a wall using the mountable holder. FIG. 32 FIG. 30 -16- FIG. 29 • Do not use rechargeable batteries. HORIZONTAL AIR-DIRECTION ADJUSTMENT • The horizontal air direction is adjusted by moving vertical louver. • The vertical louver control...In order to direct sunlight. • The remote control can be exposed to prevent discharge, remove the batteries from the remote control if the air conditioner is adjusted by moving the horizontal louvers. INSERTING THE REMOTE CONTROL BATTERIES 1.
... of the remote control, the remote sensor should not be mounted on a wall using the mountable holder. FIG. 32 FIG. 30 -16- FIG. 29 • Do not use rechargeable batteries. HORIZONTAL AIR-DIRECTION ADJUSTMENT • The horizontal air direction is adjusted by moving vertical louver. • The vertical louver control...In order to direct sunlight. • The remote control can be exposed to prevent discharge, remove the batteries from the remote control if the air conditioner is adjusted by moving the horizontal louvers. INSERTING THE REMOTE CONTROL BATTERIES 1.
Owners Manual
Page 17
...of their slots. The cabinet may be reduced, possibly damaging the unit. • Pull the inlet grille forward and pull out the air filter. (FIG. 33) • Wash the Air Filter under the faucet with liquid appliance wax. I /KN ...... Push the grille in a mild detergent solution. FIG. 33 FIG. ... Attach the front grille to the cabinet by wiping with soot or dirt from the inside air. To ensure continued peak efficiency, the condenser coils (outdoor side of the cabinet. I AIR CONDITIONER CLEANING Clean the front grille and inlet grille by inserting the tabs on the grille into place...
...of their slots. The cabinet may be reduced, possibly damaging the unit. • Pull the inlet grille forward and pull out the air filter. (FIG. 33) • Wash the Air Filter under the faucet with liquid appliance wax. I /KN ...... Push the grille in a mild detergent solution. FIG. 33 FIG. ... Attach the front grille to the cabinet by wiping with soot or dirt from the inside air. To ensure continued peak efficiency, the condenser coils (outdoor side of the cabinet. I AIR CONDITIONER CLEANING Clean the front grille and inlet grille by inserting the tabs on the grille into place...
Owners Manual
Page 18
... INSIDE ROOM WHEN UNIT IS COOLING. Then... Unit was turned off and wait 3 minutes before restarting. TEMPControlset too warm. Dirtyair filter- Air distributionis restricted. Doors,windows,registers,etc.open. SetTEMPControlto a lowertemperature. THE AIR CONDITIONER TURNS ON... AND OFF RAPIDLY. Check if... Unitis set at HI. This is OFF. ICEFORMINGON COOLINGCOILBEHINDINLETGRILLE. Cleanair filter.Referto Maintenancesectionof owner'smanual. Then... The Currentinterrupter Deviceis tripped. Wall plug disconnected. House fuse...
... INSIDE ROOM WHEN UNIT IS COOLING. Then... Unit was turned off and wait 3 minutes before restarting. TEMPControlset too warm. Dirtyair filter- Air distributionis restricted. Doors,windows,registers,etc.open. SetTEMPControlto a lowertemperature. THE AIR CONDITIONER TURNS ON... AND OFF RAPIDLY. Check if... Unitis set at HI. This is OFF. ICEFORMINGON COOLINGCOILBEHINDINLETGRILLE. Cleanair filter.Referto Maintenancesectionof owner'smanual. Then... The Currentinterrupter Deviceis tripped. Wall plug disconnected. House fuse...