Use & Care Guide
Page 1
ELECTRIC RANGE ARCHITECT® SERIES II Use & Care Guide For questions about features, operation/performance, parts, accessories or service, call: 1-800-422-1230 or visit our website at www.kitchenaid.com In Canada, call for assistance, installation and service, call: 1-800-807-6777 or visit our website at www.KitchenAid.ca Table of Contents...2 Models KERS807 KESK901 KESS907 KESS908 YKERS807 YKESS907 YKESS908 W10246111B
ELECTRIC RANGE ARCHITECT® SERIES II Use & Care Guide For questions about features, operation/performance, parts, accessories or service, call: 1-800-422-1230 or visit our website at www.kitchenaid.com In Canada, call for assistance, installation and service, call: 1-800-807-6777 or visit our website at www.KitchenAid.ca Table of Contents...2 Models KERS807 KESK901 KESS907 KESS908 YKERS807 YKESS907 YKESS908 W10246111B
Use & Care Guide
Page 4
...time to cool. IMPORTANT SAFETY INSTRUCTIONS WARNING: To reduce the risk of fire, electrical shock, injury to persons, or damage when using the range. ■ User Servicing - TO CHECK IF THE DEVICES ARE INSTALLED PROPERLY, SLIDE RANGE FORWARD, LOOK FOR ANTI-TIP BRACKET SECURELY ATTACHED TO FLOOR, AND SLIDE... RANGE BACK SO REAR RANGE FOOT IS UNDER ANTI-TIP BRACKET. ■ CAUTION: Do not store items of interest to children in water. ■ Do Not Cook on the backguard of electric shock, or fire. ■ Glazed Cooking Utensils -...
...time to cool. IMPORTANT SAFETY INSTRUCTIONS WARNING: To reduce the risk of fire, electrical shock, injury to persons, or damage when using the range. ■ User Servicing - TO CHECK IF THE DEVICES ARE INSTALLED PROPERLY, SLIDE RANGE FORWARD, LOOK FOR ANTI-TIP BRACKET SECURELY ATTACHED TO FLOOR, AND SLIDE... RANGE BACK SO REAR RANGE FOOT IS UNDER ANTI-TIP BRACKET. ■ CAUTION: Do not store items of interest to children in water. ■ Do Not Cook on the backguard of electric shock, or fire. ■ Glazed Cooking Utensils -...
Use & Care Guide
Page 10
...Large diameter cookware. ■ Large quantities of simmer temperatures) KEEP WARM ■ Keep cooked foods warm. LO-3 [SIMMER] ■ Simmer (range of food. ■ Home canning. Fire Hazard Turn off all elements off individually, or touch ALL OFF to do so can also offer assistance.... can be set to a fast and rapid boil. Cooktop Controls - REMEMBER: When range is in death or fire. This allows time for the most recently used areas to a boil. On electric cooktops, canners should not extend more information, contact your local agricultural department. HI ■...
...Large diameter cookware. ■ Large quantities of simmer temperatures) KEEP WARM ■ Keep cooked foods warm. LO-3 [SIMMER] ■ Simmer (range of food. ■ Home canning. Fire Hazard Turn off all elements off individually, or touch ALL OFF to do so can also offer assistance.... can be set to a fast and rapid boil. Cooktop Controls - REMEMBER: When range is in death or fire. This allows time for the most recently used areas to a boil. On electric cooktops, canners should not extend more information, contact your local agricultural department. HI ■...
Use & Care Guide
Page 31
... and applies only when the major appliance is operated and maintained according to instructions attached to or furnished with the product, KitchenAid will pay for Factory Specified Parts for Factory Specified Parts and repair labor to correct defects in materials or workmanship. Or ... a daytime phone number in which it was purchased. To order accessories, call the KitchenAid Customer eXperience Center toll free at 1-800-442-9991 and follow the menu prompts. KITCHENAID® ELECTRIC RANGE WARRANTY LIMITED WARRANTY For one year from the date of purchase, when this major appliance...
... and applies only when the major appliance is operated and maintained according to instructions attached to or furnished with the product, KitchenAid will pay for Factory Specified Parts for Factory Specified Parts and repair labor to correct defects in materials or workmanship. Or ... a daytime phone number in which it was purchased. To order accessories, call the KitchenAid Customer eXperience Center toll free at 1-800-442-9991 and follow the menu prompts. KITCHENAID® ELECTRIC RANGE WARRANTY LIMITED WARRANTY For one year from the date of purchase, when this major appliance...
Dimension Guide
Page 1
...range hood or microwave hood combination above the range, follow the range...Range...Range Rating chart below). Use a 3-wire UL listed, 40- q The range...range... **Range can be level...Range...use with ranges. CABINET ...range (40 amps). **Range can be level for satisfactory baking conditions. 30" (76.2 cm) Freestanding and Slide-In Electric Range PRODUCT MODEL NUMBERS OVERALL DIMENSIONS KERS807S KERS807X KESK901S KESS907S KESS908S KESS907X Freestanding Range Slide-in Range ELECTRICAL REQUIREMENTS B q This range...Range A freestanding range may need trim cut back ³...
...range hood or microwave hood combination above the range, follow the range...Range...Range Rating chart below). Use a 3-wire UL listed, 40- q The range...range... **Range can be level...Range...use with ranges. CABINET ...range (40 amps). **Range can be level for satisfactory baking conditions. 30" (76.2 cm) Freestanding and Slide-In Electric Range PRODUCT MODEL NUMBERS OVERALL DIMENSIONS KERS807S KERS807X KESK901S KESS907S KESS908S KESS907X Freestanding Range Slide-in Range ELECTRICAL REQUIREMENTS B q This range...Range A freestanding range may need trim cut back ³...
Installation Guide
Page 2
... many important safety messages in death or serious burns to rear range foot. Always read and obey all safety messages. Only 5 Electrical Requirements - TABLE OF CONTENTS RANGE SAFETY 2 INSTALLATION REQUIREMENTS 3 Tools and Parts 3 Location Requirements 3 Electrical Requirements - Canada Only 6 Countertop Preparation 7 INSTALLATION INSTRUCTIONS 7 Unpack Range 7 Measure for Proper Height 7 Adjust Leveling Legs 8 Install Anti-Tip...
... many important safety messages in death or serious burns to rear range foot. Always read and obey all safety messages. Only 5 Electrical Requirements - TABLE OF CONTENTS RANGE SAFETY 2 INSTALLATION REQUIREMENTS 3 Tools and Parts 3 Location Requirements 3 Electrical Requirements - Canada Only 6 Countertop Preparation 7 INSTALLATION INSTRUCTIONS 7 Unpack Range 7 Measure for Proper Height 7 Adjust Leveling Legs 8 Install Anti-Tip...
Installation Guide
Page 3
...rear of the slide-in cooktop and the wall in ring terminals or open-end spade terminals with the range, see "Install Anti-Tip Bracket" section. ■ Grounded electrical supply is located inside the oven door on the model/serial rating plate. If cabinet storage is the ... or microwave range hood combination that projects horizontally a minimum of 5" (12.7 cm) beyond the bottom of the Use and Care Guide to subfloor. Longer screws are included. W10113903A Biscuit - The model/serial rating plate is required. See "Electrical Requirements" section. The cord should be rated at ...
...rear of the slide-in cooktop and the wall in ring terminals or open-end spade terminals with the range, see "Install Anti-Tip Bracket" section. ■ Grounded electrical supply is located inside the oven door on the model/serial rating plate. If cabinet storage is the ... or microwave range hood combination that projects horizontally a minimum of 5" (12.7 cm) beyond the bottom of the Use and Care Guide to subfloor. Longer screws are included. W10113903A Biscuit - The model/serial rating plate is required. See "Electrical Requirements" section. The cord should be rated at ...
Installation Guide
Page 4
....0 cm) base cabinet with the current standards CAN/CSA-A240-latest edition, or local codes. See "Electrical Connection" section. Model/serial number plate (located on models KERS807XSP and KESS907XSP) beyond 24" (61.0 cm) base cabinet. front of range** F. 23" (58.4 cm) countertop notch to be raised approximately 1" (2.5 cm) by adjusting the leveling legs...
....0 cm) base cabinet with the current standards CAN/CSA-A240-latest edition, or local codes. See "Electrical Connection" section. Model/serial number plate (located on models KERS807XSP and KESS907XSP) beyond 24" (61.0 cm) base cabinet. front of range** F. 23" (58.4 cm) countertop notch to be raised approximately 1" (2.5 cm) by adjusting the leveling legs...
Installation Guide
Page 5
...Batterymarch Park Quincy, MA 02269 WARNING: Improper connection of the above the cooktop surface. Electrical Requirements - Electrical Connection To properly install your range, you must determine the type of electrical connection you are in doubt as specified on the right-hand side oven door trim... of an uncovered wood or metal cabinet. IMPORTANT: If installing a range hood or microwave hood combination above the range, follow the instructions provided for it will be connected to the proper electrical voltage and frequency as to the top of the "Location Requirements" section...
...Batterymarch Park Quincy, MA 02269 WARNING: Improper connection of the above the cooktop surface. Electrical Requirements - Electrical Connection To properly install your range, you must determine the type of electrical connection you are in doubt as specified on the right-hand side oven door trim... of an uncovered wood or metal cabinet. IMPORTANT: If installing a range hood or microwave hood combination above the range, follow the instructions provided for it will be connected to the proper electrical voltage and frequency as to the top of the "Location Requirements" section...
Installation Guide
Page 6
... is adequate and wire gauge are not sure the range is located on the supply end. Canada Only WARNING Electrical Shock Hazard Electrically ground range. If connecting to a 4-wire system: This range is manufactured with the rating of the range (40 amps). ■ The wiring diagram is ... to the cabinet. This cord contains 3 copper conductors with ring terminals or open -end spade terminals with CSA Standard C22.1, Canadian Electrical Code, Part 1 - mobile homes; Range Rating* Specified Rating of Power Supply Cord Kit and Circuit Protection 120/240 Volts 8.8 - 16.5 KW 16.6 - 22.5 KW...
... is adequate and wire gauge are not sure the range is located on the supply end. Canada Only WARNING Electrical Shock Hazard Electrically ground range. If connecting to a 4-wire system: This range is manufactured with the rating of the range (40 amps). ■ The wiring diagram is ... to the cabinet. This cord contains 3 copper conductors with ring terminals or open -end spade terminals with CSA Standard C22.1, Canadian Electrical Code, Part 1 - mobile homes; Range Rating* Specified Rating of Power Supply Cord Kit and Circuit Protection 120/240 Volts 8.8 - 16.5 KW 16.6 - 22.5 KW...
Installation Guide
Page 9
...at the bottom of your flooring, longer screws may be made. Move range into its final location, making sure rear leveling leg slides into a grounded outlet. Power Supply Cord Electrical Connection - Plug into anti-tip bracket. Remove the terminal block cover ...Remove cardboard or hardboard from the middle post of the range. U.S.A. Electrically ground range. Remove plastic tag holding three 10-32 hex nuts from under range. 8. Depending on the back of the terminal block. Failure to the subfloor. Electrical Shock Hazard Disconnect power before servicing. Disconnect power. ...
...at the bottom of your flooring, longer screws may be made. Move range into its final location, making sure rear leveling leg slides into a grounded outlet. Power Supply Cord Electrical Connection - Plug into anti-tip bracket. Remove the terminal block cover ...Remove cardboard or hardboard from the middle post of the range. U.S.A. Electrically ground range. Remove plastic tag holding three 10-32 hex nuts from under range. 8. Depending on the back of the terminal block. Failure to the subfloor. Electrical Shock Hazard Disconnect power before servicing. Disconnect power. ...
Installation Guide
Page 10
...wire direct 5" (12.7 cm) 3-wire receptacle (NEMA type 10-50R) A fused disconnect or circuit breaker box A UL listed, 250-volt minimum, 40-amp, range power supply cord 4-wire connection: Direct wire 3-wire connection: Power supply cord B A. UL listed strain relief 3-wire direct ³⁄₈" (1.0 cm) 3"...recommended) 3-wire (if 4-wire is not available) Electrical Connection Options If your home has: And you will be Go to Section: connecting to: 4-wire receptacle (NEMA type 14-50R) A UL listed, 250-volt minimum, 40-amp, range power supply cord 4-wire connection: Power supply cord...
...wire direct 5" (12.7 cm) 3-wire receptacle (NEMA type 10-50R) A fused disconnect or circuit breaker box A UL listed, 250-volt minimum, 40-amp, range power supply cord 4-wire connection: Direct wire 3-wire connection: Power supply cord B A. UL listed strain relief 3-wire direct ³⁄₈" (1.0 cm) 3"...recommended) 3-wire (if 4-wire is not available) Electrical Connection Options If your home has: And you will be Go to Section: connecting to: 4-wire receptacle (NEMA type 14-50R) A UL listed, 250-volt minimum, 40-amp, range power supply cord 4-wire connection: Power supply cord...
Installation Guide
Page 12
...1 (black) wires to easily attach the wiring terminal block. 3. Strip the insulation back ³⁄₈" (1.0 cm) from the back of range. Line 2 (red) wire F. Ground-link screw D. Tighten strain relief screws. 6. Strip outer covering back 3" (7.6 cm) to line 1... block post with 10-32 hex nuts. 4. Pull the wires through bottom of electrical supply (4-wire or 3-wire connection). 4-wire Connection: Direct Wire Use this method for use with nominal 1³⁄₈" (3.5 cm) diameter connection opening, with ranges. 5. A E A B C D B C A. 10-32 hex nut...
...1 (black) wires to easily attach the wiring terminal block. 3. Strip the insulation back ³⁄₈" (1.0 cm) from the back of range. Line 2 (red) wire F. Ground-link screw D. Tighten strain relief screws. 6. Strip outer covering back 3" (7.6 cm) to line 1... block post with 10-32 hex nuts. 4. Pull the wires through bottom of electrical supply (4-wire or 3-wire connection). 4-wire Connection: Direct Wire Use this method for use with nominal 1³⁄₈" (3.5 cm) diameter connection opening, with ranges. 5. A E A B C D B C A. 10-32 hex nut...
Installation Guide
Page 14
... Guide. 6. Connect anti-tip bracket to see which step was skipped. 2. For more information, read the "Range Care" section of the drawer and pull out. 2. Level Range 1. or circuit breaker has not tripped. ■ Range is plugged into an outlet. ■ Electrical supply is an extra part, go back through the steps to rear...
... Guide. 6. Connect anti-tip bracket to see which step was skipped. 2. For more information, read the "Range Care" section of the drawer and pull out. 2. Level Range 1. or circuit breaker has not tripped. ■ Range is plugged into an outlet. ■ Electrical supply is an extra part, go back through the steps to rear...
Installation Guide
Page 15
... installed: ■ Look for the anti-tip bracket securely attached to floor. ■ Slide range back so rear range foot is necessary for the anti-tip bracket securely attached to perform cleaning or maintenance. 3. For direct-wired ranges: WARNING Electrical Shock Hazard Disconnect power before operating. Disconnect power. 2. Using two or more people, slide...
... installed: ■ Look for the anti-tip bracket securely attached to floor. ■ Slide range back so rear range foot is necessary for the anti-tip bracket securely attached to perform cleaning or maintenance. 3. For direct-wired ranges: WARNING Electrical Shock Hazard Disconnect power before operating. Disconnect power. 2. Using two or more people, slide...