Installation Guide
Page 1
....4 CM) WALL-MOUNT CANOPY RANGE HOOD Installation Instructions and Use & Care Guide For questions about features, operation/performance, parts, accessories or service, call: 1-800-422-1230 or visit our website at www.kitchenaid.com In Canada, for assistance, installation and service, call: 1-800-807-6777 or visit our website at www....kitchenaid.ca HOTTE D'EXTRACTION À MONTAGE MURAL DE 30" (76,2 CM) ET 36" (91,4 CM) Instructions d'installation et Guide d'utilisation et d'entretien Au Canada, ...
....4 CM) WALL-MOUNT CANOPY RANGE HOOD Installation Instructions and Use & Care Guide For questions about features, operation/performance, parts, accessories or service, call: 1-800-422-1230 or visit our website at www.kitchenaid.com In Canada, for assistance, installation and service, call: 1-800-807-6777 or visit our website at www....kitchenaid.ca HOTTE D'EXTRACTION À MONTAGE MURAL DE 30" (76,2 CM) ET 36" (91,4 CM) Instructions d'installation et Guide d'utilisation et d'entretien Au Canada, ...
Installation Guide
Page 2
... safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING." TABLE OF CONTENTS RANGE HOOD SAFETY 2 INSTALLATION REQUIREMENTS 3 Tools and Parts 3 Location Requirements 4 Venting Requirements 5 Electrical Requirements 6 INSTALLATION INSTRUCTIONS 6 Prepare Location 6 Install Range Hood 7 Connect Vent System 7 Make Electrical Connection 8 Install Vent Covers 9 Complete Installation 9 RANGE...
... safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING." TABLE OF CONTENTS RANGE HOOD SAFETY 2 INSTALLATION REQUIREMENTS 3 Tools and Parts 3 Location Requirements 4 Venting Requirements 5 Electrical Requirements 6 INSTALLATION INSTRUCTIONS 6 Prepare Location 6 Install Range Hood 7 Connect Vent System 7 Make Electrical Connection 8 Install Vent Covers 9 Complete Installation 9 RANGE...
Installation Guide
Page 3
... cm 9.5 mm), and 7.9 mm) drill bits ■ Jigsaw or keyhole saw ■ Flat-blade screwdriver ■ Metal snips ■ Phillips screwdriver Parts Needed ■ Home power supply cable ■ Pencil ■ ½" (12.7 mm) UL listed or CSA approved strain relief ■ Wire stripper ...within walls or ceilings, attics or into wall or ceiling; READ AND SAVE THESE INSTRUCTIONS INSTALLATION REQUIREMENTS Tools and Parts Gather the required tools and parts before starting installation. IMPORTANT SAFETY INSTRUCTIONS WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO ...
... cm 9.5 mm), and 7.9 mm) drill bits ■ Jigsaw or keyhole saw ■ Flat-blade screwdriver ■ Metal snips ■ Phillips screwdriver Parts Needed ■ Home power supply cable ■ Pencil ■ ½" (12.7 mm) UL listed or CSA approved strain relief ■ Wire stripper ...within walls or ceilings, attics or into wall or ceiling; READ AND SAVE THESE INSTRUCTIONS INSTALLATION REQUIREMENTS Tools and Parts Gather the required tools and parts before starting installation. IMPORTANT SAFETY INSTRUCTIONS WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO ...
Installation Guide
Page 4
...minimum clearance. Grounded electrical outlet is the installer's responsibility to the Manufactured Home Construction Safety Standards, Title 24 CFR, Part 328 (formerly the Federal Standard for Manufactured Home Installation 1982 (Manufactured Home Sites, Communities and Setups) ANSI A225.1/NFPA...anchors (4) ■ 3.5 x 9.5 mm sheet metal screws (2) ■ T10 TORX®† adapter Location Requirements IMPORTANT: Observe all parts are shown must be used. Check that are included. ■ Hood canopy assembly with ventilator and light bulbs installed ■ Vent transition...
...minimum clearance. Grounded electrical outlet is the installer's responsibility to the Manufactured Home Construction Safety Standards, Title 24 CFR, Part 328 (formerly the Federal Standard for Manufactured Home Installation 1982 (Manufactured Home Sites, Communities and Setups) ANSI A225.1/NFPA...anchors (4) ■ 3.5 x 9.5 mm sheet metal screws (2) ■ T10 TORX®† adapter Location Requirements IMPORTANT: Observe all parts are shown must be used. Check that are included. ■ Hood canopy assembly with ventilator and light bulbs installed ■ Vent transition...
Installation Guide
Page 5
... are adjustable and designed to locale. Rigid metal vent is 6" (15.2 cm) round. The specified CFM varies from your dealer or an authorized parts distributor. The hood exhaust opening around the cap. ■ The size of outside , the hood can terminate either through the wall. Roof Venting ... to meet varying ceiling or soffit heights depending on the cold air side of the house. For higher ceilings, a Stainless Steel Chimney Extension Kit Part Number W10272075 is 35 ft (10.7 m). 5 The break should be kept to a minimum to where the vent system enters the heated portion ...
... are adjustable and designed to locale. Rigid metal vent is 6" (15.2 cm) round. The specified CFM varies from your dealer or an authorized parts distributor. The hood exhaust opening around the cap. ■ The size of outside , the hood can terminate either through the wall. Roof Venting ... to meet varying ceiling or soffit heights depending on the cold air side of the house. For higher ceilings, a Stainless Steel Chimney Extension Kit Part Number W10272075 is 35 ft (10.7 m). 5 The break should be kept to a minimum to where the vent system enters the heated portion ...
Installation Guide
Page 6
A copy of the National Electrical Code, ANSI/NFPA 70 (latest edition), or CSA Standards C22. 1-94, Canadian Electrical Code, Part 1 and C22.2 No. 0-M91 (latest edition) and all local codes and ordinances. Mark a reference line on the wall where the canopy...hood. ■ Wire sizes must conform with National Electrical Code, ANSI/NFPA 70 (latest edition), or CSA Standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No. 0-M91 (latest edition) and all governing codes and ordinances. Follow the electrical connector manufacturer's recommended procedure. Determine which ...
A copy of the National Electrical Code, ANSI/NFPA 70 (latest edition), or CSA Standards C22. 1-94, Canadian Electrical Code, Part 1 and C22.2 No. 0-M91 (latest edition) and all local codes and ordinances. Mark a reference line on the wall where the canopy...hood. ■ Wire sizes must conform with National Electrical Code, ANSI/NFPA 70 (latest edition), or CSA Standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No. 0-M91 (latest edition) and all governing codes and ordinances. Follow the electrical connector manufacturer's recommended procedure. Determine which ...
Installation Guide
Page 8
... C. Black wires F D. White wires F. Green (or bare) and yellow- Disconnect power. 2. Vent duct E. Seal connections with the duct cover bracket using 4 - 4 x 8 mm screws. Replace all parts and panels before servicing. X = length to do so can result in the terminal box cover and install a UL listed or CSA approved ¹⁄₂...
... C. Black wires F D. White wires F. Green (or bare) and yellow- Disconnect power. 2. Vent duct E. Seal connections with the duct cover bracket using 4 - 4 x 8 mm screws. Replace all parts and panels before servicing. X = length to do so can result in the terminal box cover and install a UL listed or CSA approved ¹⁄₂...
Installation Guide
Page 13
... also look in your request. To locate factory specified replacement parts in your nearest designated service center. KitchenAid designated service technicians are trained to KitchenAid with any questions or concerns at www.kitchenaid.com. Mississauga, Ontario L5N 0B7 Please include a daytime phone...calling for non-vented installations only) Order Part Number W10344022 Chimney Extension Kit Order Part Number W10272075 6" (15.2 cm) Makeup Air Kit (consult local building codes) Order Part Number W10446915 In Canada Call the KitchenAid Canada Customer eXperience Centre toll free: 1-800...
... also look in your request. To locate factory specified replacement parts in your nearest designated service center. KitchenAid designated service technicians are trained to KitchenAid with any questions or concerns at www.kitchenaid.com. Mississauga, Ontario L5N 0B7 Please include a daytime phone...calling for non-vented installations only) Order Part Number W10344022 Chimney Extension Kit Order Part Number W10272075 6" (15.2 cm) Makeup Air Kit (consult local building codes) Order Part Number W10446915 In Canada Call the KitchenAid Canada Customer eXperience Centre toll free: 1-800...
Installation Guide
Page 14
...when your major appliance is used for product service if your major appliance for Factory Specified Parts and repair labor to use of consumables or cleaning products not approved by a KitchenAid designated service company. IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR ... major appliance is designed to correct house wiring or plumbing. 2. Write down the following information about your authorized KitchenAid dealer to parts or systems resulting from warranty coverage. 3. In the U.S.A., call 1-800-807-6777. 9/07 Keep this limited ...
...when your major appliance is used for product service if your major appliance for Factory Specified Parts and repair labor to use of consumables or cleaning products not approved by a KitchenAid designated service company. IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR ... major appliance is designed to correct house wiring or plumbing. 2. Write down the following information about your authorized KitchenAid dealer to parts or systems resulting from warranty coverage. 3. In the U.S.A., call 1-800-807-6777. 9/07 Keep this limited ...
Dimension Guide
Page 1
...together. Vented Installations Min. q The vent system must terminate to locale. q The size of the vent should be as close as part of canopy to cooking surface Centerline Cooking surface *For non-vented (recirculating) installations IMPORTANT: Minimum distance "X": 24" (61.0 cm) from... locale to the outdoors, except for planning purposes only. Consult your dealer or an authorized parts distributor. Page 1 of 2 Because Whirlpool Corporation policy includes a continuous commitment to improve Dimensions are adjustable and designed to meet varying...
...together. Vented Installations Min. q The vent system must terminate to locale. q The size of the vent should be as close as part of canopy to cooking surface Centerline Cooking surface *For non-vented (recirculating) installations IMPORTANT: Minimum distance "X": 24" (61.0 cm) from... locale to the outdoors, except for planning purposes only. Consult your dealer or an authorized parts distributor. Page 1 of 2 Because Whirlpool Corporation policy includes a continuous commitment to improve Dimensions are adjustable and designed to meet varying...
Warranty Information
Page 1
... is operated and maintained according to instructions attached to or furnished with the product, KitchenAid brand of Whirlpool Corporation or Whirlpool Canada LP (hereafter "KitchenAid") will need to know your complete model number and serial number. Repairs to parts or systems resulting from warranty coverage. 3. Write down the following information about your major...
... is operated and maintained according to instructions attached to or furnished with the product, KitchenAid brand of Whirlpool Corporation or Whirlpool Canada LP (hereafter "KitchenAid") will need to know your complete model number and serial number. Repairs to parts or systems resulting from warranty coverage. 3. Write down the following information about your major...
Use & Care Guide
Page 1
...WALL-MOUNT CANOPY RANGE HOOD Installation Instructions and Use & Care Guide For questions about features, operation/performance, parts, accessories or service, call: 1-800-422-1230 or visit our website at www.kitchenaid.com In Canada, for assistance, installation and service, call: 1-800-807-6777 or visit our website...entretien Au Canada, pour assistance, installation ou service composez le 1-800-807-6777 ou visitez notre site web à www.kitchenaid.ca Table of Contents/Table des matières 2 IMPORTANT: READ AND SAVE THESE INSTRUCTIONS. POUR UTILISATION RÉSIDENTIELLE UNIQUEMENT.
...WALL-MOUNT CANOPY RANGE HOOD Installation Instructions and Use & Care Guide For questions about features, operation/performance, parts, accessories or service, call: 1-800-422-1230 or visit our website at www.kitchenaid.com In Canada, for assistance, installation and service, call: 1-800-807-6777 or visit our website...entretien Au Canada, pour assistance, installation ou service composez le 1-800-807-6777 ou visitez notre site web à www.kitchenaid.ca Table of Contents/Table des matières 2 IMPORTANT: READ AND SAVE THESE INSTRUCTIONS. POUR UTILISATION RÉSIDENTIELLE UNIQUEMENT.
Use & Care Guide
Page 2
.... This is , tell you how to cause cancer. Always read and obey all safety messages. TABLE OF CONTENTS RANGE HOOD SAFETY 2 INSTALLATION REQUIREMENTS 3 Tools and Parts 3 Location Requirements 4 Venting Requirements 5 Electrical Requirements 6 INSTALLATION INSTRUCTIONS 6 Prepare Location 6 Install Range Hood 7 Connect Vent System 7 Make Electrical Connection 8 Install Vent Covers 9 Complete Installation 9 RANGE...
.... This is , tell you how to cause cancer. Always read and obey all safety messages. TABLE OF CONTENTS RANGE HOOD SAFETY 2 INSTALLATION REQUIREMENTS 3 Tools and Parts 3 Location Requirements 4 Venting Requirements 5 Electrical Requirements 6 INSTALLATION INSTRUCTIONS 6 Prepare Location 6 Install Range Hood 7 Connect Vent System 7 Make Electrical Connection 8 Install Vent Covers 9 Complete Installation 9 RANGE...
Use & Care Guide
Page 3
...cm 9.5 mm), and 7.9 mm) drill bits ■ Jigsaw or keyhole saw ■ Flat-blade screwdriver ■ Metal snips ■ Phillips screwdriver Parts Needed ■ Home power supply cable ■ Pencil ■ ½" (12.7 mm) UL listed or CSA approved strain relief ■ Wire ...metal tray, then turn hood ON when cooking at high settings. READ AND SAVE THESE INSTRUCTIONS INSTALLATION REQUIREMENTS Tools and Parts Gather the required tools and parts before starting installation. If you have a class ABC extinguisher, and you have questions, contact the manufacturer. ■...
...cm 9.5 mm), and 7.9 mm) drill bits ■ Jigsaw or keyhole saw ■ Flat-blade screwdriver ■ Metal snips ■ Phillips screwdriver Parts Needed ■ Home power supply cable ■ Pencil ■ ½" (12.7 mm) UL listed or CSA approved strain relief ■ Wire ...metal tray, then turn hood ON when cooking at high settings. READ AND SAVE THESE INSTRUCTIONS INSTALLATION REQUIREMENTS Tools and Parts Gather the required tools and parts before starting installation. If you have a class ABC extinguisher, and you have questions, contact the manufacturer. ■...
Use & Care Guide
Page 4
... 2" (5.1 cm) min. 9" (22.9 cm) min.* 9¹⁄₂" (24.1 cm) 10" (25.4 cm) min. 13" (33.0 cm) max. Parts Supplied Remove parts from strong draft areas, such as windows, doors and strong heating vents. The model/serial rating plate is the installer's responsibility to cooking surface...24" (61.0 cm) from gas cooking surfaces. For Non-Vented (Recirculating) Installations, You Will Also Need: ■ Recirculation Kit Part Number W10344022 for venting through the roof or wall. See "Assistance or Service" section to the Manufactured Home Construction Safety Standards, Title 24...
... 2" (5.1 cm) min. 9" (22.9 cm) min.* 9¹⁄₂" (24.1 cm) 10" (25.4 cm) min. 13" (33.0 cm) max. Parts Supplied Remove parts from strong draft areas, such as windows, doors and strong heating vents. The model/serial rating plate is the installer's responsibility to cooking surface...24" (61.0 cm) from gas cooking surfaces. For Non-Vented (Recirculating) Installations, You Will Also Need: ■ Recirculation Kit Part Number W10344022 for venting through the roof or wall. See "Assistance or Service" section to the Manufactured Home Construction Safety Standards, Title 24...
Use & Care Guide
Page 5
...*NOTE: The range hood chimneys are adjustable and designed to provide efficient performance. Makeup Air Local building codes may be as close as part of the range hood and the cooking surface. The damper should be installed immediately above the hood. Flexible vent creates back pressure and air...extension replaces the chimney shipped with the range hood. ■ Use caulking to seal all joints in your dealer or an authorized parts distributor. Diverter B. 6" (15.2 cm) round vent Calculating Vent System Length To calculate the length of straight vent between the...
...*NOTE: The range hood chimneys are adjustable and designed to provide efficient performance. Makeup Air Local building codes may be as close as part of the range hood and the cooking surface. The damper should be installed immediately above the hood. Flexible vent creates back pressure and air...extension replaces the chimney shipped with the range hood. ■ Use caulking to seal all joints in your dealer or an authorized parts distributor. Diverter B. 6" (15.2 cm) round vent Calculating Vent System Length To calculate the length of straight vent between the...
Use & Care Guide
Page 6
...template with hood bottom line and with National Electrical Code, ANSI/NFPA 70 (latest edition), or CSA Standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No. 0-M91 (latest edition) and all local codes and ordinances. The model/serial plate is installed. INSTALLATION INSTRUCTIONS ...maximum recommended vent length of the National Electrical Code, ANSI/NFPA 70 (latest edition), or CSA Standards C22. 1-94, Canadian Electrical Code, Part 1 and C22.2 No. 0-M91 (latest edition) and all governing codes and ordinances. Range Hood Mounting Screws Installation ■ Before making ...
...template with hood bottom line and with National Electrical Code, ANSI/NFPA 70 (latest edition), or CSA Standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No. 0-M91 (latest edition) and all local codes and ordinances. The model/serial plate is installed. INSTALLATION INSTRUCTIONS ...maximum recommended vent length of the National Electrical Code, ANSI/NFPA 70 (latest edition), or CSA Standards C22. 1-94, Canadian Electrical Code, Part 1 and C22.2 No. 0-M91 (latest edition) and all governing codes and ordinances. Range Hood Mounting Screws Installation ■ Before making ...
Use & Care Guide
Page 8
... wire connectors E. X = length to the measured size (X). 4. Cut the duct to cut vent duct D. Green (or bare) and yellow- Measure from the hood. 7. Replace all parts and panels before servicing. A. UL listed or CSA approved strain relief C. Knockout B. Assembly screws B. Disconnect power. 2. Terminal box cover 4. green ground wires 5.
... wire connectors E. X = length to the measured size (X). 4. Cut the duct to cut vent duct D. Green (or bare) and yellow- Measure from the hood. 7. Replace all parts and panels before servicing. A. UL listed or CSA approved strain relief C. Knockout B. Assembly screws B. Disconnect power. 2. Terminal box cover 4. green ground wires 5.
Use & Care Guide
Page 13
...our full line of appliances. ■ Use and maintenance procedures. ■ Accessory and repair parts sales. ■ Referrals to KitchenAid with any questions or concerns at www.kitchenaid.com. Mississauga, Ontario L5N 0B7 Please include a daytime phone number in your appliance. This information... calling for non-vented installations only) Order Part Number W10344022 Chimney Extension Kit Order Part Number W10272075 6" (15.2 cm) Makeup Air Kit (consult local building codes) Order Part Number W10446915 In Canada Call the KitchenAid Canada Customer eXperience Centre toll free: 1-800...
...our full line of appliances. ■ Use and maintenance procedures. ■ Accessory and repair parts sales. ■ Referrals to KitchenAid with any questions or concerns at www.kitchenaid.com. Mississauga, Ontario L5N 0B7 Please include a daytime phone number in your appliance. This information... calling for non-vented installations only) Order Part Number W10344022 Chimney Extension Kit Order Part Number W10272075 6" (15.2 cm) Makeup Air Kit (consult local building codes) Order Part Number W10446915 In Canada Call the KitchenAid Canada Customer eXperience Centre toll free: 1-800...
Use & Care Guide
Page 14
... single-family household use of original purchase date is required to obtain service under these excluded circumstances shall be provided by a KitchenAid designated service company. Major appliances with original model/serial numbers that is contrary to published user or operator instructions and/or installation ...in a manner that have been removed, altered or cannot be repaired in the home and only in -warranty service. Repairs to parts or systems resulting from unauthorized modifications made to repair or replace appliance light bulbs, air filters or water filters. This warranty is...
... single-family household use of original purchase date is required to obtain service under these excluded circumstances shall be provided by a KitchenAid designated service company. Major appliances with original model/serial numbers that is contrary to published user or operator instructions and/or installation ...in a manner that have been removed, altered or cannot be repaired in the home and only in -warranty service. Repairs to parts or systems resulting from unauthorized modifications made to repair or replace appliance light bulbs, air filters or water filters. This warranty is...