Datasheet
Page 1
...-and-forward switching architecture - With MAC address autolearning and auto-aging, IEEE802.3x flow control for full-duplex mode and backpressure for crossover cables or Uplink ports. Each port can be used as GSW-5150 allows you can link up with IEEE 802.3, 802.3u and 802.3ab, 802.3z standards - SFP Slot 4. Not a problem. Transfer your network reach. Wire-speed packet filtering and forwarding rate - 8K MAC Address and 128KB buffer memory - And with the fiber connection...
...-and-forward switching architecture - With MAC address autolearning and auto-aging, IEEE802.3x flow control for full-duplex mode and backpressure for crossover cables or Uplink ports. Each port can be used as GSW-5150 allows you can link up with IEEE 802.3, 802.3u and 802.3ab, 802.3z standards - SFP Slot 4. Not a problem. Transfer your network reach. Wire-speed packet filtering and forwarding rate - 8K MAC Address and 128KB buffer memory - And with the fiber connection...
Datasheet
Page 2
... Mac Address 8K MAC address table Product Diagram Internet Broadband Router Ethernet Switch 3 Physical Specifications Power Supply 100 ~ 240V AC/50~60Hz Internal Power LED Power, Link/Activity Operating Environment Temperature: 0°C ~ 40°C Humidity: 10% ~ 90% (Non-condensing) Storage: -40°C ~ 70°C Dimensions 440mm (W) x 260 mm (D) x 44mm (H) Certification FCC Class A, CE GSW-5150 Server PC Order Information Package Contents GSW-5150: 48 FE + 2 GE + 1 GE SFP Switch GSW-5150 Power Cord Rack-mount kit User Manual All...
... Mac Address 8K MAC address table Product Diagram Internet Broadband Router Ethernet Switch 3 Physical Specifications Power Supply 100 ~ 240V AC/50~60Hz Internal Power LED Power, Link/Activity Operating Environment Temperature: 0°C ~ 40°C Humidity: 10% ~ 90% (Non-condensing) Storage: -40°C ~ 70°C Dimensions 440mm (W) x 260 mm (D) x 44mm (H) Certification FCC Class A, CE GSW-5150 Server PC Order Information Package Contents GSW-5150: 48 FE + 2 GE + 1 GE SFP Switch GSW-5150 Power Cord Rack-mount kit User Manual All...
Manual
Page 2
.... These limits are subject to change without permission from Digital Data Communications Co., Ltd. This equipment generates, uses and can be reproduced in a particular installation. No part of the FCC Rules. FCC STATEMENT The 48-Port Fast Ethernet TP+ 3-Port Gigabit Ethernet TP/SFP Switch has been tested and found to comply with the instructions, may be determined by turning the equipment off and on...
.... These limits are subject to change without permission from Digital Data Communications Co., Ltd. This equipment generates, uses and can be reproduced in a particular installation. No part of the FCC Rules. FCC STATEMENT The 48-Port Fast Ethernet TP+ 3-Port Gigabit Ethernet TP/SFP Switch has been tested and found to comply with the instructions, may be determined by turning the equipment off and on...
Manual
Page 3
There may be a remote risk of the following standards: EN55022 EN55024 EN60950 SAFETY NOTICES Caution: Do not use this product near water, for example, in a wet basement or near a swimming pool. Avoid using this product during an electrical storm. EC DECLARATION OF CONFORMITY (EUROPE) In compliance with the EMC Directive 89/336/EEC, Low Voltage Directive 73/23/EEC, this product meets the requirements of electric shock from lightning.
There may be a remote risk of the following standards: EN55022 EN55024 EN60950 SAFETY NOTICES Caution: Do not use this product near water, for example, in a wet basement or near a swimming pool. Avoid using this product during an electrical storm. EC DECLARATION OF CONFORMITY (EUROPE) In compliance with the EMC Directive 89/336/EEC, Low Voltage Directive 73/23/EEC, this product meets the requirements of electric shock from lightning.
Manual
Page 4
TABLE OF CONTENTS Package Contents 1 Chapter 1: Introduction of the Product 2 1.1 Overview of the product 2 1.2 Features...2 Chapter 2: Installation 3 2.1 Mounting the Switch on a Desk 3 2.2 Mounting the Switch in a Rack 4 2.3 Mounting the SFP module 5 2.4 Power on...5 Chapter 3: Identifying External Components 5 3.1 Front Panel...5 3.2 Rear Panel...6 Appendix A: Specifications 7
TABLE OF CONTENTS Package Contents 1 Chapter 1: Introduction of the Product 2 1.1 Overview of the product 2 1.2 Features...2 Chapter 2: Installation 3 2.1 Mounting the Switch on a Desk 3 2.2 Mounting the Switch in a Rack 4 2.3 Mounting the SFP module 5 2.4 Power on...5 Chapter 3: Identifying External Components 5 3.1 Front Panel...5 3.2 Rear Panel...6 Appendix A: Specifications 7
Manual
Page 5
GSW-5150 48-Port Fast Ethernet +3-Port Gigabit Package Contents: The following contents should be found in your box: One Switch One power cord This User's Guide Rubber footpads for Desk-mount Rack-mount kit for installing the switch in a 19-inch rack Note: If any of the above contents is damaged or missing, please contact the retailer from whom you purchased the GSW-5150 Gigabit Ethernet Switch for assistance.
GSW-5150 48-Port Fast Ethernet +3-Port Gigabit Package Contents: The following contents should be found in your box: One Switch One power cord This User's Guide Rubber footpads for Desk-mount Rack-mount kit for installing the switch in a 19-inch rack Note: If any of the above contents is damaged or missing, please contact the retailer from whom you purchased the GSW-5150 Gigabit Ethernet Switch for assistance.
Manual
Page 6
... your network server and backbone connections, make Gigabit connection to a server or uplink a network necessarily. Each port can be used as general ports or Uplink ports, and any port can be simply plugged into a server, a hub, a router or a switch, using the straight cable or crossover cable. The GSW-5150 is plug-and-play and no configuration is standard-based. Diagnostic LEDs which display link status and activity, allowing you with all ports eliminate the need for Half Duplex mode. GSW-5150 48-Port Fast Ethernet +3-Port Gigabit...
... your network server and backbone connections, make Gigabit connection to a server or uplink a network necessarily. Each port can be used as general ports or Uplink ports, and any port can be simply plugged into a server, a hub, a router or a switch, using the straight cable or crossover cable. The GSW-5150 is plug-and-play and no configuration is standard-based. Diagnostic LEDs which display link status and activity, allowing you with all ports eliminate the need for Half Duplex mode. GSW-5150 48-Port Fast Ethernet +3-Port Gigabit...
Manual
Page 7
... for crossover cable or Uplink port. Non-blocking switching architecture that forwards and filters packets at fullwire -speed for maximum throughput. Supports MAC address auto-learning and auto-aging Supports IEEE802.3x flow control for full-duplex model and backpressure for half-duplex transfer model LED indicators for radiating heat and air. Note: Make sure there is free space for monitoring power, link, activity, speed Internal power supply Chapter 2: Installation 2.1 Mounting the Switch on a Desk...
... for crossover cable or Uplink port. Non-blocking switching architecture that forwards and filters packets at fullwire -speed for maximum throughput. Supports MAC address auto-learning and auto-aging Supports IEEE802.3x flow control for full-duplex model and backpressure for half-duplex transfer model LED indicators for radiating heat and air. Note: Make sure there is free space for monitoring power, link, activity, speed Internal power supply Chapter 2: Installation 2.1 Mounting the Switch on a Desk...
Manual
Page 8
... GIGA2 48-Port Gigabit FEathsteErntheet rTnPe/tSTFPP+S3w-Pitocrht SFP Link/Act Figure 2-2 Fasten the Switch in the rack Turn off all the equipment connected to the standard 19'' rackmountable steel case of the Switch, fasten it in the rack, then rivet the two ' L' brackets onto each side of Electronic Industries Association. GSW-5150 48-Port Fast Ethernet +3-Port Gigabit 2.2 Mounting the Switch in a Rack The dimension of GSW-5150 is designed...
... GIGA2 48-Port Gigabit FEathsteErntheet rTnPe/tSTFPP+S3w-Pitocrht SFP Link/Act Figure 2-2 Fasten the Switch in the rack Turn off all the equipment connected to the standard 19'' rackmountable steel case of the Switch, fasten it in the rack, then rivet the two ' L' brackets onto each side of Electronic Industries Association. GSW-5150 48-Port Fast Ethernet +3-Port Gigabit 2.2 Mounting the Switch in a Rack The dimension of GSW-5150 is designed...
Manual
Page 9
Powering on GSW-5150 Switch is powered by AC power supply. And- Should fixed the SFP into SFP pluggable when use the SFP module.The switch could identify and Config the SFP module automatically. 2.4 Power on the Switch, it will automatically initialize and its LED indicators should respond as follows: 1) All of the LED indicators will flash momentarily for one second, which support The Hot Plug- Chapter 3: Identifying External Components This Chapter describes...
Powering on GSW-5150 Switch is powered by AC power supply. And- Should fixed the SFP into SFP pluggable when use the SFP module.The switch could identify and Config the SFP module automatically. 2.4 Power on the Switch, it will automatically initialize and its LED indicators should respond as follows: 1) All of the LED indicators will flash momentarily for one second, which support The Hot Plug- Chapter 3: Identifying External Components This Chapter describes...
Manual
Page 10
..., please check the power supply and connection. 1000M LED: The corresponding gigabit port LED indicator will light solid green when the SFP port connected correctly It flashes green when data is being transmitted or received on the working connection. 3.2 Rear Panel The rear panel of the GSW-5150 only features a power receptacle, which are used for the Switch along with an explanation of the Switch. GSW-5150 48-Port Fast Ethernet +3-Port Gigabit LED indicators The LED indicators include Power, Link/Act, 1000Mbps...
..., please check the power supply and connection. 1000M LED: The corresponding gigabit port LED indicator will light solid green when the SFP port connected correctly It flashes green when data is being transmitted or received on the working connection. 3.2 Rear Panel The rear panel of the GSW-5150 only features a power receptacle, which are used for the Switch along with an explanation of the Switch. GSW-5150 48-Port Fast Ethernet +3-Port Gigabit LED indicators The LED indicators include Power, Link/Act, 1000Mbps...
Manual
Page 11
... mode fiber 50 u m multi mode fiber 1000Base-LX: 62.5 u m multi mode fiber 50 u m multi mode fiber 9 u m/10 u m single mode fiber Number of Ports 48 10/100Mbps Auto-Negotiation RJ-45 ports 2 10/100/1000Mbps Auto-Negotiation RJ-45 ports 1 SFP module Interface UpLink Ports Auto MDI/MDI-X cable detection, Each port can be used Uplink ports Transfer Method Store-and-Forward MAC AddresTable 8k, Automatically learning, automatically Update Frame Filter Rate 10Base-T: 14880pps/Port 100Base-Tx: 148800pps/Port 1000Base-T: 1488000pps/Port 1000Base-X: 1488000pps/Port Frame Forward 10Base...
... mode fiber 50 u m multi mode fiber 1000Base-LX: 62.5 u m multi mode fiber 50 u m multi mode fiber 9 u m/10 u m single mode fiber Number of Ports 48 10/100Mbps Auto-Negotiation RJ-45 ports 2 10/100/1000Mbps Auto-Negotiation RJ-45 ports 1 SFP module Interface UpLink Ports Auto MDI/MDI-X cable detection, Each port can be used Uplink ports Transfer Method Store-and-Forward MAC AddresTable 8k, Automatically learning, automatically Update Frame Filter Rate 10Base-T: 14880pps/Port 100Base-Tx: 148800pps/Port 1000Base-T: 1488000pps/Port 1000Base-X: 1488000pps/Port Frame Forward 10Base...
Manual
Page 12
GSW-5150 48-Port Fast Ethernet +3-Port Gigabit Environmental and Physical Power maximum 35W Operating Temperature 0°C ~40°C Storage Temperature -40°C ~70°C Operating Humidity 10%~90% non-condensing Storage Humidity 5%~95% non-condensing Dimensions 17.3×10.2×1.73 in.(440 mm×260 mm×44mm) 8
GSW-5150 48-Port Fast Ethernet +3-Port Gigabit Environmental and Physical Power maximum 35W Operating Temperature 0°C ~40°C Storage Temperature -40°C ~70°C Operating Humidity 10%~90% non-condensing Storage Humidity 5%~95% non-condensing Dimensions 17.3×10.2×1.73 in.(440 mm×260 mm×44mm) 8
EU Declaration of Conformity
Page 1
...-4-5:2005 - IEC 61000-4-11:2004 This declaration gets responsible for Digital-Data-Communications GmbH Zeche-Norm-Stral3e 25 Class A 44319 Dortmund Germany Dortmund, 10 of Conformity Communications For the following product: LevelOne 48-Port Fast Ethernet TP + 3-Port Gigabit Ethernet TP/SFP Switch Model: GSW-5150 Item-No.: 524751 48-Port Fast Ethernet TP + 3-Port Gigabit Ethernet TP/SFP The product above is in accordance with the EMC directive 2004...
...-4-5:2005 - IEC 61000-4-11:2004 This declaration gets responsible for Digital-Data-Communications GmbH Zeche-Norm-Stral3e 25 Class A 44319 Dortmund Germany Dortmund, 10 of Conformity Communications For the following product: LevelOne 48-Port Fast Ethernet TP + 3-Port Gigabit Ethernet TP/SFP Switch Model: GSW-5150 Item-No.: 524751 48-Port Fast Ethernet TP + 3-Port Gigabit Ethernet TP/SFP The product above is in accordance with the EMC directive 2004...