Service Manual
Page 67
...Run) I Air Purging with a Flare Tool 3-4. Tubing Connections 3-6. Recommended Wire Length and Diameter 5-3. Wiring Instructions for Installation 2. TEST RUN 25 NOTE 7. CONNECTING A HOME AUTOMATION DEVICE 26 The illustrations are installing. 8. Use of SANYO North America... KMS1872 KMS2472 Outdoor Unit CM1972 CM2472 CM3172 CLM1972 CLM2472 CLM3172 Combine indoor and outdoor units only as listed below. 1. AIR PURGING 18 I Pump Down 5. Caution before Connecting Tubes Tightly 3-5. Inverter Multi Split System Air Conditioner - Accessories Supplied with Unit ...
...Run) I Air Purging with a Flare Tool 3-4. Tubing Connections 3-6. Recommended Wire Length and Diameter 5-3. Wiring Instructions for Installation 2. TEST RUN 25 NOTE 7. CONNECTING A HOME AUTOMATION DEVICE 26 The illustrations are installing. 8. Use of SANYO North America... KMS1872 KMS2472 Outdoor Unit CM1972 CM2472 CM3172 CLM1972 CLM2472 CLM3172 Combine indoor and outdoor units only as listed below. 1. AIR PURGING 18 I Pump Down 5. Caution before Connecting Tubes Tightly 3-5. Inverter Multi Split System Air Conditioner - Accessories Supplied with Unit ...
Service Manual
Page 71
....)* CM1972/CLM1972 82 150 (L1+L2+L3) 150 (L1+L2+L3) 50 - Electrical noise from any of these sources may affect operation. Table 3 Model Max. CM2472/CLM2472 82 150 (L1+L2+L3+L4) 200 (L1+L2+L3+L4) 50 0.22 CM3172/CLM3172 100 150 (L1+L2+L3+L4) 230 (L1+L2+L3...
....)* CM1972/CLM1972 82 150 (L1+L2+L3) 150 (L1+L2+L3) 50 - Electrical noise from any of these sources may affect operation. Table 3 Model Max. CM2472/CLM2472 82 150 (L1+L2+L3+L4) 200 (L1+L2+L3+L4) 50 0.22 CM3172/CLM3172 100 150 (L1+L2+L3+L4) 230 (L1+L2+L3...
Service Manual
Page 72
... connecting tubes of different sizes (3/8"(9.52mm) 1/2"(12.70mm)) Supplied Reducer Indoor unit (KMS0772,KMS0972,KMS1272) (KMS0772,KMS0972,KMS1272) (KMS1872) Fig. 4b (2) Connecting indoor unit for CM2472/CLM2472 (A) Outdoor unit D 3/8"(9.52mm) 3/8"(9.52mm) C 1/4"(6.35mm) 3/8"(9.52mm) 3/8"(9.52mm) B 1/4"(6.35mm) 3/8"(9.52mm) 3/8"(9.52mm) A 1/4"(6.35mm) 3/8"(9.52mm) 1/2"(12.70mm) 1/4"(6.35mm) Flare 1/2"(12.70mm) Union 3/8"(9.52mm) (1/2"(12.70mm) 3/8"(9.52mm)) Supplied Reducer...
... connecting tubes of different sizes (3/8"(9.52mm) 1/2"(12.70mm)) Supplied Reducer Indoor unit (KMS0772,KMS0972,KMS1272) (KMS0772,KMS0972,KMS1272) (KMS1872) Fig. 4b (2) Connecting indoor unit for CM2472/CLM2472 (A) Outdoor unit D 3/8"(9.52mm) 3/8"(9.52mm) C 1/4"(6.35mm) 3/8"(9.52mm) 3/8"(9.52mm) B 1/4"(6.35mm) 3/8"(9.52mm) 3/8"(9.52mm) A 1/4"(6.35mm) 3/8"(9.52mm) 1/2"(12.70mm) 1/4"(6.35mm) Flare 1/2"(12.70mm) Union 3/8"(9.52mm) (1/2"(12.70mm) 3/8"(9.52mm)) Supplied Reducer...
Service Manual
Page 79
... tube side (Outer diameter 1/4"(6.35)) Service valve on wide tube side (Outer diameter 3/8"(9.52)) 2-3/4 29-1/8 (740) 2-3/4 2-15/16 2-27/32 23/32 4-7/16 5-29/32 (2) CM2472/CLM2472 23-15/16 5-11/32 15/32 A 12-19/32 13-19/32 14-17/32 Fig. 6a 1-13/16 2-1/16 A 35-7/16 (900) 2-29...
... tube side (Outer diameter 1/4"(6.35)) Service valve on wide tube side (Outer diameter 3/8"(9.52)) 2-3/4 29-1/8 (740) 2-3/4 2-15/16 2-27/32 23/32 4-7/16 5-29/32 (2) CM2472/CLM2472 23-15/16 5-11/32 15/32 A 12-19/32 13-19/32 14-17/32 Fig. 6a 1-13/16 2-1/16 A 35-7/16 (900) 2-29...
Service Manual
Page 87
... on its nameplate, then carry out the wiring closely following the wiring diagram. (2) Provide a power outlet to be very dangerous. Table 6 Model AWG CM1972 / CLM1972 CM2472 / CLM2472 CM3172 / CLM3172 Max. AWG (American Wire Gauge) 21 The manufacturer will accept no responsibility for control line and power line and fuse or circuit capacity...
... on its nameplate, then carry out the wiring closely following the wiring diagram. (2) Provide a power outlet to be very dangerous. Table 6 Model AWG CM1972 / CLM1972 CM2472 / CLM2472 CM3172 / CLM3172 Max. AWG (American Wire Gauge) 21 The manufacturer will accept no responsibility for control line and power line and fuse or circuit capacity...
Service Manual
Page 88
CAUTION WARNING G To avoid the risk of electric shock, each air conditioner unit must be required by high tension. G Be sure to connect the power supply line to the outdoor unit as shown in order to release ... Diagram * NOTE Disconnect switch may be firmly connected. ing up numbers on running the wire from other grounds and do not have it shared with CM2472/CLM2472, CM3172/CLM3172 L1 Power supply L2 Single-phase 230/208VAC 60HZ Grounding line * Disconnect switch Field supply INDOOR UNIT Terminal 1 230/208V OUTDOOR UNIT UNIT...
CAUTION WARNING G To avoid the risk of electric shock, each air conditioner unit must be required by high tension. G Be sure to connect the power supply line to the outdoor unit as shown in order to release ... Diagram * NOTE Disconnect switch may be firmly connected. ing up numbers on running the wire from other grounds and do not have it shared with CM2472/CLM2472, CM3172/CLM3172 L1 Power supply L2 Single-phase 230/208VAC 60HZ Grounding line * Disconnect switch Field supply INDOOR UNIT Terminal 1 230/208V OUTDOOR UNIT UNIT...