Omada SDN Controller Software 4.1.5Windows/Linux User Guide
Page 134
... will assign IP address to the selected local networks. Each WAN port supports only one PPTP VPN tunnel when the gateway works as a PPTP server. Enter the IP address and subnet mask to -Point Encryption) for an IP address and the server supplies the IP addresses from the configured subnet to connect to load the following page. Enter the password of user. Select the networks on which...
... will assign IP address to the selected local networks. Each WAN port supports only one PPTP VPN tunnel when the gateway works as a PPTP server. Enter the IP address and subnet mask to -Point Encryption) for an IP address and the server supplies the IP addresses from the configured subnet to connect to load the following page. Enter the password of user. Select the networks on which...
Omada SDN Controller Software 4.1.5Windows/Linux User Guide
Page 202
... enabled, enter the authentication code as the Sender Address. 196 SMTP Port SSL Authentication Username Password Sender Address Enter the URL or IP address of the email service provider. Go to the instructions of the SMTP server according to Settings > Controller. SSL (Secure Sockets Layer) is enabled, enter your email address as the password, which is enabled, the SMTP server requires the username and password for authentication. Chapter 5 Configure the Omada SDN Controller...
... enabled, enter the authentication code as the Sender Address. 196 SMTP Port SSL Authentication Username Password Sender Address Enter the URL or IP address of the email service provider. Go to the instructions of the SMTP server according to Settings > Controller. SSL (Secure Sockets Layer) is enabled, enter your email address as the password, which is enabled, the SMTP server requires the username and password for authentication. Chapter 5 Configure the Omada SDN Controller...
Omada SDN Controller Software 4.1.5Windows/Linux User Guide
Page 245
... same speed, duplex, jumbo and flow control mode. • A port cannot be set as the default All profile and Switching operation. • The port enabled with Port Security, Port Mirror, MAC Address Filtering or 802.1X cannot be added to the LAG, specify the LAG ID, and choose a LAG type. For example, if the local end works in the same LAG mode. If an active link fails, the other active links share the bandwidth evenly. • One LACP LAG supports multiple member ports...
... same speed, duplex, jumbo and flow control mode. • A port cannot be set as the default All profile and Switching operation. • The port enabled with Port Security, Port Mirror, MAC Address Filtering or 802.1X cannot be added to the LAG, specify the LAG ID, and choose a LAG type. For example, if the local end works in the same LAG mode. If an active link fails, the other active links share the bandwidth evenly. • One LACP LAG supports multiple member ports...
Omada SDN Controller Software 4.1.5Windows/Linux User Guide
Page 247
... and Switching operation. Once deleted, the ports will be configured vary in different colors. : The LAG profile is connected to it , click to Configure a LAG. The parameters to be configured as a LAG, refer to change the profile. : The port is enabled, but no device or client is Disable. Status Ports Profile Action Displays the status in Operation modes. 241 Displays the port number of LAG ports. Chapter 6 Configure and Monitor Omada Managed Devices ■■ LAG LAGs (Link Aggregation Groups...
... and Switching operation. Once deleted, the ports will be configured vary in different colors. : The LAG profile is connected to it , click to Configure a LAG. The parameters to be configured as a LAG, refer to change the profile. : The port is enabled, but no device or client is Disable. Status Ports Profile Action Displays the status in Operation modes. 241 Displays the port number of LAG ports. Chapter 6 Configure and Monitor Omada Managed Devices ■■ LAG LAGs (Link Aggregation Groups...
Omada SDN Controller Software 4.1.5Windows/Linux User Guide
Page 325
... if Authentication is used by sending a test email to the instructions of the email service provider. SSL (Secure Sockets Layer) is enabled. In the Mail Server section, enable SMTP Server and configure the parameters. Then click Save. Enable or disable SSL according to create an encrypted link between the controller and the SMTP server. Chapter 8 Monitor the Network Enable Mail Server Enable Alert Emails in Site Enable Alert Emails in Admin Go to Settings > Controller.
... if Authentication is used by sending a test email to the instructions of the email service provider. SSL (Secure Sockets Layer) is enabled. In the Mail Server section, enable SMTP Server and configure the parameters. Then click Save. Enable or disable SSL according to create an encrypted link between the controller and the SMTP server. Chapter 8 Monitor the Network Enable Mail Server Enable Alert Emails in Site Enable Alert Emails in Admin Go to Settings > Controller.
TL-SG2428PUN V1 CLI Reference Guide Guide
Page 58
...:35 Switch (config)# system-time manual 12/20/2010-17:30:35 5.2 system-time ntp Description The system-time ntp command is used to configure the time zone and the IP address for the NTP Server. Set the date and time manually, MM/DD/YYYY-HH:MM:SS. Chapter 5 System Configuration Commands System Commands can be used to configure the System information and System IP, reboot and reset the switch, upgrade the switch system and other operations. 5.1 system-time manual...
...:35 Switch (config)# system-time manual 12/20/2010-17:30:35 5.2 system-time ntp Description The system-time ntp command is used to configure the time zone and the IP address for the NTP Server. Set the date and time manually, MM/DD/YYYY-HH:MM:SS. Chapter 5 System Configuration Commands System Commands can be used to configure the System information and System IP, reboot and reset the switch, upgrade the switch system and other operations. 5.1 system-time manual...
TL-SG2428PUN V1 CLI Reference Guide Guide
Page 68
... the same subnet, the controller inform-url command is used to inform the switch of the controller whose IP address is 192.168.1.1: Switch (config)# controller inform-url 192.168.1.1 5.14 reset Description The reset command is used to these commands. Command Mode Gloabal Configuration Mode Privilege Requirement Only Admin, Operator and Power User level users have access to reset the switch's software. Specify the URL of Omada SDN Controller. Example Inform the switch of the controller's URL/IP address. controller-ip --
... the same subnet, the controller inform-url command is used to inform the switch of the controller whose IP address is 192.168.1.1: Switch (config)# controller inform-url 192.168.1.1 5.14 reset Description The reset command is used to these commands. Command Mode Gloabal Configuration Mode Privilege Requirement Only Admin, Operator and Power User level users have access to reset the switch's software. Specify the URL of Omada SDN Controller. Example Inform the switch of the controller's URL/IP address. controller-ip --
TL-SG2428PUN V1 CLI Reference Guide Guide
Page 77
...Example Delete the backup image file: Switch # remove backup-image 5.28 firmware upgrade Description The firmware upgrade command is used to upgrade the switch's backup iamge file via the TFTP server. Syntax firmware upgrade tftp ip-address ip-addr filename name Parameter ip-addr -- Both IPv4 and IPv6 addresses are supported, for the firmware file. 5.27 remove backup-image Description The remove backup-image command is used to delete the backup-image. name -- Command Mode Privileged EXEC Mode Privilege Requirement Only Admin level users have access to these commands. 53 IP Address...
...Example Delete the backup image file: Switch # remove backup-image 5.28 firmware upgrade Description The firmware upgrade command is used to upgrade the switch's backup iamge file via the TFTP server. Syntax firmware upgrade tftp ip-address ip-addr filename name Parameter ip-addr -- Both IPv4 and IPv6 addresses are supported, for the firmware file. 5.27 remove backup-image Description The remove backup-image command is used to delete the backup-image. name -- Command Mode Privileged EXEC Mode Privilege Requirement Only Admin level users have access to these commands. 53 IP Address...
TL-SG2428PUN V1 CLI Reference Guide Guide
Page 525
... snmp-server traps power command. The command without parameter enables all PoE traps. All PoE traps are disabled by the connected PDs exceeds the maximum power the PoE switch can be triggered when the switch detects an IP conflict event. Parameter change traps. Command Mode Global Configuration Mode Privilege Requirement Only Admin level users have access to enable PoE traps. The trap can supply. The trap monitors the IP changed . Enable SNMP IP change -- port-pwr-change | port-pwr-deny | port-pwr-over-30w | port...
... snmp-server traps power command. The command without parameter enables all PoE traps. All PoE traps are disabled by the connected PDs exceeds the maximum power the PoE switch can be triggered when the switch detects an IP conflict event. Parameter change traps. Command Mode Global Configuration Mode Privilege Requirement Only Admin level users have access to enable PoE traps. The trap can supply. The trap monitors the IP changed . Enable SNMP IP change -- port-pwr-change | port-pwr-deny | port-pwr-over-30w | port...
Jetstream Smart Switches User Guide
Page 34
... server and HTTPS server, for user authentication. Accessing the Switch Web Interface Access 2 Web Interface Access You can access the switch's web interface through a web browser in the host PC: 1) Make sure that the route between the host PC and the switch is 192.168.0.1. Figure 2-1 Enter the Switch's IP Address in the Browser 4) Enter the username and password (both admin by default) in , change the password to login via the HTTP server. 2.1 Login To manage your network and devices. The switch uses...
... server and HTTPS server, for user authentication. Accessing the Switch Web Interface Access 2 Web Interface Access You can access the switch's web interface through a web browser in the host PC: 1) Make sure that the route between the host PC and the switch is 192.168.0.1. Figure 2-1 Enter the Switch's IP Address in the Browser 4) Enter the username and password (both admin by default) in , change the password to login via the HTTP server. 2.1 Login To manage your network and devices. The switch uses...
Jetstream Smart Switches User Guide
Page 89
... device supports this feature, refer to quickly configure the PoE parameters. If PoE configuration is available, there is only available on certain devices. User Guide 60 With the PoE feature, you can: ■■ Configure the PoE parameters manually ■■ Configure the PoE parameters using the profile You can also set a profile with the desired parameters and bind the profile to the corresponding ports to the actual web interface...
... device supports this feature, refer to quickly configure the PoE parameters. If PoE configuration is available, there is only available on certain devices. User Guide 60 With the PoE feature, you can: ■■ Configure the PoE parameters manually ■■ Configure the PoE parameters using the profile You can also set a profile with the desired parameters and bind the profile to the corresponding ports to the actual web interface...
Jetstream Smart Switches User Guide
Page 367
... ports. 5) (Optional) Statically add ports to Configuring 802.1Q VLAN. User Guide 338 When both are connecting to the hosts) according to the multicast VLAN. Note that receive multicast data from the router) to one VLAN and cannot be enabled on the underlying mechanism of IGMP Snooping, but the two features operate independently of each other multicast groups are managed by IGMP Snooping. 4.1 Using the GUI 4.1.1 Configuring 802.1Q VLANs Before configuring MVR, create an 802.1Q VLAN...
... ports. 5) (Optional) Statically add ports to Configuring 802.1Q VLAN. User Guide 338 When both are connecting to the hosts) according to the multicast VLAN. Note that receive multicast data from the router) to one VLAN and cannot be enabled on the underlying mechanism of IGMP Snooping, but the two features operate independently of each other multicast groups are managed by IGMP Snooping. 4.1 Using the GUI 4.1.1 Configuring 802.1Q VLANs Before configuring MVR, create an 802.1Q VLAN...
Jetstream Smart Switches User Guide
Page 860
...#configure Switch(config)#access-list bind 1 interface vlan 4 gigabitEthernet 1/0/3 SSwitch(config)#show access-list bind ACL ID ACL NAME Interface/VID Direction Type ----- ---------- ------- ---- 1 ACL_1 Gi1/0/3 Ingress Port 1 ACL_1 4 Ingress VLAN Switch(config)#end Switch#copy running -config startup-config Save the settings in the privileged EXEC mode and any other configuration mode: show access-list acl-id-or-name counter View the number of matched packets of the ACL to view the number of matched packets of each ACL in the configuration file. User Guide...
...#configure Switch(config)#access-list bind 1 interface vlan 4 gigabitEthernet 1/0/3 SSwitch(config)#show access-list bind ACL ID ACL NAME Interface/VID Direction Type ----- ---------- ------- ---- 1 ACL_1 Gi1/0/3 Ingress Port 1 ACL_1 4 Ingress VLAN Switch(config)#end Switch#copy running -config startup-config Save the settings in the privileged EXEC mode and any other configuration mode: show access-list acl-id-or-name counter View the number of matched packets of the ACL to view the number of matched packets of each ACL in the configuration file. User Guide...
Jetstream Smart Switches User Guide
Page 1088
... running-config startup-config Save the settings in IPv4 or IPv6. User Guide 1059 When the NMS host uses SNMPv1 or SNMPv2c, enter the Community Name; Note that the switch waits for a response. For SNMPv1, the supported type is 3. And it does not receive a response from the NMS host within the timeout interval. timeout: Set the time that if you change the port number under...
... running-config startup-config Save the settings in IPv4 or IPv6. User Guide 1059 When the NMS host uses SNMPv1 or SNMPv2c, enter the Community Name; Note that the switch waits for a response. For SNMPv1, the supported type is 3. And it does not receive a response from the NMS host within the timeout interval. timeout: Set the time that if you change the port number under...
TL-SX3008FUN V1 Installation Guide
Page 11
... a time. When the switch has an RJ45 console port and a micro-USB console port, console input is active on only one console port at 100 Mbps and transmitting or receiving data. Green Flashing: Running at 1 Gbps and transmitting or receiving data. Yellow Flashing: Running at 10 Gbps and transmitting or receiving data. Note: For TL-SG3428XMP Console Port Designed to install the 10 Gbps SFP+ module. SFP/SFP+ Slot SFP slot is designed to connect with...
... a time. When the switch has an RJ45 console port and a micro-USB console port, console input is active on only one console port at 100 Mbps and transmitting or receiving data. Green Flashing: Running at 1 Gbps and transmitting or receiving data. Yellow Flashing: Running at 10 Gbps and transmitting or receiving data. Note: For TL-SG3428XMP Console Port Designed to install the 10 Gbps SFP+ module. SFP/SFP+ Slot SFP slot is designed to connect with...
TL-SX3008FUN V1 Installation Guide
Page 20
... network and devices. 3. The first time you log in the lower case letters to configure and manage the switch using GUI (Graphical User Interface) or CLI (command-line interface). Figure 4-1 Topology for both the username and password in , change the password to the User Guide and CLI Guide. Note: When the switch is recommended in . For details, refer to the related documents on the download center of our official website: https://www.tp-link.com/support/download/. 4.2 Standalone Mode In Standalone Mode, use...
... network and devices. 3. The first time you log in the lower case letters to configure and manage the switch using GUI (Graphical User Interface) or CLI (command-line interface). Figure 4-1 Topology for both the username and password in , change the password to the User Guide and CLI Guide. Note: When the switch is recommended in . For details, refer to the related documents on the download center of our official website: https://www.tp-link.com/support/download/. 4.2 Standalone Mode In Standalone Mode, use...
TL-SX3008FUN V1 Installation Guide
Page 22
... the router's web page, and both the username and password are admin by default. On the Omada Controller's web page, follow the next steps: a. Follow the steps below to complete the quick setup. 5. Launch a web browser and enter https://omada.tplinkcloud.com in . tp-link.com/support/download/omada-software-controller/. JetStream L2/L2+ Managed Switch • A DHCP server (typically a router with Windows OS or Linux OS, download the Omada Software Controller from https://www. After the quick setup, the login...
... the router's web page, and both the username and password are admin by default. On the Omada Controller's web page, follow the next steps: a. Follow the steps below to complete the quick setup. 5. Launch a web browser and enter https://omada.tplinkcloud.com in . tp-link.com/support/download/omada-software-controller/. JetStream L2/L2+ Managed Switch • A DHCP server (typically a router with Windows OS or Linux OS, download the Omada Software Controller from https://www. After the quick setup, the login...
TL-SX3008FUN V1 Installation Guide
Page 23
... the quick setup, the login page appears. On the Omada Controller's web page, go to Settings > Cloud Access to Manage the Network. 2. If you can also manage your controller at a local site or a remote site via your TP-Link ID. b. Enter your TP-Link ID and password to your TP-Link ID and password to log in . Enable Cloud Access on the setting page on the download center of controllers that have created and click Log in the setup...
... the quick setup, the login page appears. On the Omada Controller's web page, go to Settings > Cloud Access to Manage the Network. 2. If you can also manage your controller at a local site or a remote site via your TP-Link ID. b. Enter your TP-Link ID and password to your TP-Link ID and password to log in . Enable Cloud Access on the setting page on the download center of controllers that have created and click Log in the setup...
TL-SX3008FUN V1 Installation Guide
Page 24
... sure the power supply is normal and the console cable is the right type. 3. Check if the console cable is properly connected. 2. JetStream L2/L2+ Managed Switch Appendix A Troubleshooting Q1. The bootUtil menu will not be shown. The default login username and password are correct: configure Bits per second as 38400, Data bits as 8, Parity as None, Stop bits as 1, and Flow control as None. 21 Appendix A Troubleshooting The PWR/Power LED should...
... sure the power supply is normal and the console cable is the right type. 3. Check if the console cable is properly connected. 2. JetStream L2/L2+ Managed Switch Appendix A Troubleshooting Q1. The bootUtil menu will not be shown. The default login username and password are correct: configure Bits per second as 38400, Data bits as 8, Parity as None, Stop bits as 1, and Flow control as None. 21 Appendix A Troubleshooting The PWR/Power LED should...
Omada SDN Software Controller 4.2.8windows&linux User Guide
Page 134
... -Point Encryption) for an IP address and the server supplies the IP addresses from the configured subnet to connect to load the following page. Username Password Mode Enter the username used for the validation before accessing the network. Chapter 4 Configure the Network with Omada SDN Controller MPPE Encryption Local Networks WAN IP Pool Specify whether to enable MPPE (Microsoft Point-to the remote host when the tunnel is established...
... -Point Encryption) for an IP address and the server supplies the IP addresses from the configured subnet to connect to load the following page. Username Password Mode Enter the username used for the validation before accessing the network. Chapter 4 Configure the Network with Omada SDN Controller MPPE Encryption Local Networks WAN IP Pool Specify whether to enable MPPE (Microsoft Point-to the remote host when the tunnel is established...