Get support for Honeywell MS1690 - Metrologic Focus - Wired Handheld Barcode Scanner

Honeywell MS1690 Support Question

Honeywell MS1690 Support Question

Find answers below for this question about Honeywell MS1690 - Metrologic Focus - Wired Handheld Barcode Scanner.
Need a Honeywell MS1690 manual? We have 1 online manual for this item!
Question posted by Anonymous-143026 on September 7th, 2014

Scanner Not Scanning

While the scanner is on the stand there is constantly yellow light but when we try to scan the item there is constantly blue and yellow light but it is not beeping or there is no white light and it is not scanning anything. How can we fix the problem?

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Honeywell MS1690 Manual Pages

User Guide - Page 1

METROLOGIC INSTRUMENTS, INC. MS1690 Focus™ Area Imaging Bar Code Scanner Installation and User's Guide
User Guide - Page 5

..., RX, RTS, CTS, DTR) MS1690 - 38 Low Speed USB MS1690 - 40 MS1690 - 47 Full Speed USB Keyboard Wedge, Stand-Alone Keyboard and RS232 Transmit/Receive 1 Sharp images can be captured and transmitted in -stand scanning. Focus incorporates Metrologic's patented CodeGate® technology for superior image quality. INTRODUCTION The MS1690 Focus is presented within the scanner's field of both 1D...
User Guide - Page 6

...02098 MS1690 Focus Area Imaging Bar Code Scanner Installation and User's Guide* * Available on the Metrologic website - To order additional items, contact the dealer, distributor or call Metrologic's Customer...-53020-3 Stand Alone Keyboard PowerLink Cable 2.7 m (9 ft.) coiled cord, long strain relief, black Other items may be ordered for the specific protocol being used. www.metrologic.com Part...
User Guide - Page 7

...long strain relief, black MVC-2MPC-IB9 Metrologic Voltage Converter (MVC) Cable* ±12VDC to +5.2VDC * Contact a Metrologic customer service representative for additional information on the MVC cable series and the host connections available. 00-02001 MS1690 Focus Stand (46-00147) Installation Guide 46-00147 Modular Presentation Stand Other items may be ordered for the specific protocol...
User Guide - Page 9

DISCONNECTING Before removing the cable from the scanner, Metrologic recommends that the power on the strain-relief of the unit near the cable. 2. Figure 4. Insert the paperclip (or other small metallic pin) into the ...
User Guide - Page 10

... a bar code. Label Samples and Location Maintenance Smudges and dirt can interfere with the proper scanning of manufacture, serial number, CE and caution information. Spray glass cleaner onto lint free, non-abrasive cleaning cloth. 2. INTRODUCTION Labels Each scanner has a label located on the underside of the label and its location. The following...
User Guide - Page 11

...Focus. In addition, please check that the scanner is ready for instructions on changing the scanner's configuration. Turn off the host device. 2. Plugging the scanner into the power jack on the host system does not guarantee that scanned information will light...The scanner is made. 3. Plug the power supply into a port on the PowerLink cable. All LEDs (yellow, white, and blue) ...
User Guide - Page 12

...scanner has finished initializing the LEDs will stop flashing and the unit will beep 3 times indicating that the scanner and host system are using the same communication protocol. Turn on the Focus.... Plugging the scanner into the power jack on the host system does not guarantee that scanned information will light for a limited power source. 8 All LEDs (yellow, white, and blue) will be ...
User Guide - Page 13

Figure 8. 6. All LEDs (yellow, white, and blue) will beep 3 times indicating that the scanner is ready for use. 7. When the scanner has finished initializing the LEDs will stop flashing and the unit will light for SELV (Safety Extra Low Voltage) according to the MetroSelect Single-Line Configuration Guide (MLPN 00-02544) or MetroSet2's help files for a limited...
User Guide - Page 14

.... 10 You will light for SELV (Safety Extra Low Voltage) according to alternately flash. Focus will beep 3 times indicating that the scanner is shipped from the factory configured with default settings. In addition, please check that scanned information will be communicated properly to the host system. INSTALLING THE SCANNER TO THE HOST SYSTEM IBM MS1690-11 1. Figure...
User Guide - Page 15

... addition, please check that scanned information will beep 3 times indicating that the scanner is ready for USB Serial Emulation Mode, please refer to the host device. As a default, the MS1690-38 leaves the factory with default settings. INSTALLING THE SCANNER TO THE HOST SYSTEM Integrated USB: Full Speed MS1690-40 Low Speed MS1690-38 1. Turn on the...
User Guide - Page 19

... please refer to scan. 4. CodeGate, Out-of light over the bar code. 3. Aim the scanner's line of -Stand 1. The IR detects...scanner continuously attempts to scan the bar code until either it will beep once, the white LED will flash and the decoded data will stop trying to the MS1690 Focus Supplemental Configuration Guide (MLPN 00-02065). 15 Presentation, In-Stand Figure 14. SCANNER...
User Guide - Page 20

... indicator (see Failure Modes on page 18). SCANNER OPERATION Audible Indicators When the Focus is in this mode. If the scanner does not beep once and the white light does not turn on , then the bar code has not been successfully read. All LEDs (yellow, white, and blue) will beep 3 times indicating that the single configuration bar code...
User Guide - Page 21

... the in configuration mode. If the host is not ready to decode a barcode. The scanner is in the stand. Steady Yellow The yellow LED is illuminated when the scanner is in stand-by mode. Steady White When the scanner successfully reads a bar code it will beep once and the white LED will turn on , the flashing or stationary activity...
User Guide - Page 22

SCANNER OPERATION Failure Modes Long Razzberry Tone - Short Razzberry Tone - During Scanning An Invalid bar code has been scanned when in configuration mode or the trigger has been pulled too fast. 18 If the scanner does not respond after reprogramming, return the scanner for repair. During Power Up Failed to initialize or configure the scanner.
User Guide - Page 25

... is being supplied to preserve the limited warranty terms. All Interfaces MS1690 Series Troubleshooting Guide Symptoms Possible Causes Solution No LEDs, beep or illumination No power is a scanning mechanism failure. Contact a Metrologic Service Representative if the unit will not hold the saved configuration. scanner from the host. The wrong communication cable has been used...
User Guide - Page 26

... locks up , but does not scan and/or beep. If the scanner is setup to the host is incorrect. The scanner is connected to scan a barcode that the scanner is trying to the proper host port. 22 Make sure that does not match the configured criteria. The unit powers up after the first scan and the white LED stays...
User Guide - Page 27

... not work with the bar code. The unit scans the bar code but the data is suspect. The configuration is out of tolerance. The scanner and host may have been printed incorrectly. The type... of printer could be configured for the same interface parameters. The unit beeps at some bar codes and NOT...
User Guide - Page 36

... at the desired scanner options. This program can be downloaded for FREE from Metrologic' website (www.metrologic.com) or set-up disks can be ordered by scanning the bar codes...MS1690 can be configured by calling 1-800-ID-METRO. • Serial Programming This mode of the bar codes located in the Metrologic Single-Line Configuration Guide (MLPN 00-02544). CONFIGURATION MODES The MS1690 Focus...
User Guide - Page 42

... must be returned to the original purchase price. IN NO EVENT SHALL ANY LIABILITY OF METROLOGIC EXCEED THE ACTUAL AMOUNT PAID TO METROLOGIC FOR THE PRODUCT. In the event that all MS1690 Focus scanners are manufactured by anyone other than Metrologic's repair department or authorized repair centers. THIS LIMITED WARRANTY, EXCEPT AS TO TITLE, IS IN...

Similar Questions

Ms1690 Focus It Reads Barcode But Not Qr Code
my Scanner scans Barcode but not qr code I tried enable qr code option but it didn't work.does anyon...
(Posted by rujilratna 8 years ago)
2d Scanner Not Working After Scanning Usb Serial Barcode
I scanned the USB Serial barcode in error instead of the USB PC Keyboard option and now it will not ...
(Posted by jonnorton 8 years ago)
Ms1690 Driver
I purchased a Metrologic Scanner used and cant get it to work as it requires a Driver to reset the f...
(Posted by dpooley 10 years ago)
Ask a New Question
Use the box below to post a new question about this Honeywell product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Honeywell Manuals

Find free Honeywell MS1690 - Metrologic Focus - Wired Handheld Barcode Scanner manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Honeywell Reviews

View thousands of Honeywell user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Honeywell customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Honeywell customer service rankings, employee comments and much more from our sister site.

Honeywell Recalls

Find comprehensive Honeywell recall information updated hourly on RecallOwl.com.