Get support for Sanyo CLM2472 - 25,400 BTU Ductless Multi-Split Low Ambient Air Conditioner

Sanyo CLM2472 Support Question

Sanyo CLM2472 Support Question

Find answers below for this question about Sanyo CLM2472 - 25,400 BTU Ductless Multi-Split Low Ambient Air Conditioner.
Need a Sanyo CLM2472 manual? We have 1 online manual for this item!
Question posted by cnickell on October 10th, 2012

Cerificate Of Calibration

how long is the certificate of calibration on a sanyo medicool unit, and what will it cost to get a new certificate?  

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Sanyo CLM2472 Manual Pages

Service Manual - Page 1

...Table" in the Appendix of this manual. Pay special attention when servicing the unit. TECHNICAL & SERVICE MANUAL OUTDOOR UNIT : CLM1972 CLM2472 CLM3172 FILE NO. REFERENCE NO. CLM3172 IMPORTANT These air conditioners employ new refrigerant R410A. Destination: North America DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity at 230V 19,700 BTU/h 25,400 BTU/h 30,600 BTU/h Outdoor Model No.
Service Manual - Page 6

... refer to 253 7.0 1,570 98 12.5 16.5 13.0 20 Outdoor Unit Microprocessor Auto (Hi and multi-steps) DC Twin Rotary (Inverter) R410A / 6.17 (2,800) Electric Expansion Valve 50 Flare Type 82 (25) 1/4 (6.35) × 3 3/8 (9.52) × 3 Outdoor Unit 29-1/8 × 35-7/16 × 12-19/32 (740 × 900 × 320) 33-27/32...
Service Manual - Page 7

... refer to 253 7.7 1,570 98 12.5 16.5 13.0 20 Outdoor Unit Microprocessor Auto (Hi and multi-steps) DC Twin Rotary (Inverter) R410A / 6.17 (2,800) Electric Expansion Valve 50 Flare Type 82 (25) 1/4 (6.35) × 3 3/8 (9.52) × 3 Outdoor Unit 29-1/8 × 35-7/16 × 12-19/32 (740 × 900 × 320) 33-27/32...
Service Manual - Page 8

....ft (m3) < 230V > 4-Room Multi Outdoor Unit 4 3 230V Single-Phase 60Hz Cooling 25,400 ( 9,800 to 25,400 ) 7.50 ( 2.90 to 7.50 ) 21,400 4,000 1,707 (2,900) 187 to the "Unit Combination Tables" in performance section and electrical rating section above are : Cooling : Indoor air temp. 80°F D.B./ 67°F W.B. Indoor Unit : KMS0972 3units Outdoor Unit : CLM2472 1unit 2. The values shown in...
Service Manual - Page 9

....ft (m3) < 208V > 4-Room Multi Outdoor Unit 4 3 208V Single-Phase 60Hz Cooling 24,400 ( 9,800 to 24,400 ) 7.20 ( 2.90 to 7.20 ) 20,600 3,800 1,707 (2,900) 187 to the "Unit Combination Tables" in performance section and electrical rating section above are : Cooling : Indoor air temp. 80°F D.B./ 67°F W.B. Outdoor Unit CLM2472 Indoor Unit KMS0972 × 3 Type Number...
Service Manual - Page 10

... Volume inch (mm) inch (mm) Ibs (kg) Ibs (kg) cu.ft (m3) < 230V > 4-Room Multi Outdoor Unit 4 4 230V Single-Phase 60Hz Cooling 30,600 ( 9,800 to 30,600 ) 9.00 ( 2.90 to 9.00 ) 25,800 4,800 1,942 (3,300) 187 to the "Unit Combination Tables" in performance section and electrical rating section above are : Cooling : Indoor...
Service Manual - Page 11

... to 8.40 ) 24,200 4,400 1,942 (3,300) 187 to the "Unit Combination Tables" in performance section and electrical rating section above are : Cooling : Indoor air temp. 80°F D.B./ 67°F W.B. For other combination unit, please refer to 253 13.6 2,800 99 10.2 17.6 17.0 20 Outdoor Unit Microprocessor Auto (Hi and multi-steps) DC Twin Rotary...
Service Manual - Page 37

Outdoor Unit : CLM2472 Indoor Unit : KMS0972 × 3 Power Supply : 230V Single Phase 60Hz < Cooling Capacity > RATING CAPACITY: INDOOR ENT. D.B. 25,400 BTU/h 65 (18.3) TC 25,690 AIR FLOW RATE: OUTDOOR AMBIENT TEMP. Rating conditions (#) : Indoor Unit Entering Air Temp. 80 °F (26.7 °C) D.B. / 67 °F (19.4 °C) W.B. : Outdoor Ambient Temp. 95 °F (35 °C) D.B. ...
Service Manual - Page 38

...88 (31.1) SHC SHC SHC SHC SHC TC 25,580 29,470 31,170 31,170 31,...,600 17,120 21,240 23,400 23,400 23,400 23,770 14,610 16,970 ...BTU/h) SHC : Sensible Heat Capacity (BTU/h) NOTE 1. D.B. 30,600 BTU/h 65 (18.3) TC 31,170 AIR FLOW RATE: OUTDOOR AMBIENT TEMP. Rating conditions (#) : Indoor Unit Entering Air Temp. 80 °F (26.7 °C) D.B. / 67 °F (19.4 °C) W.B. : Outdoor Ambient...
Service Manual - Page 39

...cooling characteristics. 2. oF (oC) W.B. oF (oC) 20 (-6.7) 25 (-3.9) 35 (1.7) 20,000 19,990 19,980 883 CFM 45 (7.2)...,530 16,790 19,700 21,030 21,400 10,790 13,700 16,790 19,870 ...BTU/h TC AIR FLOW RATE: OUTDOOR AMBIENT TEMP. Above data represents the value when the operation frequency of a compressor is fixed. 39 5-3. Cooling Capacity (Low Ambient) Outdoor Unit : CLM1972 Indoor Unit...
Service Manual - Page 40

... the operation frequency of a compressor is fixed. 40 D.B. 25,400 BTU/h TC AIR FLOW RATE: OUTDOOR AMBIENT TEMP. oF (oC) W.B. For this reason, the value may vary from the actual cooling characteristics. 2. Outdoor Unit : CLM2472 Indoor Unit : KMS0972 × 3 Power Supply : 230V Single Phase 60Hz < Cooling Capacity (Low Ambient) > RATING CAPACITY: INDOOR ENT. Above data does not...
Service Manual - Page 41

...operation into account. D.B. 30,600 BTU/h TC AIR FLOW RATE: OUTDOOR AMBIENT TEMP. oF (oC) 20 (-6.7) 25 (-3.9) 35 (1.7) 30,720 30,...BTU/h) SHC : Sensible Heat Capacity (BTU/h) NOTE 1. For this reason, the value may vary from the actual cooling characteristics. 2. Outdoor Unit : CLM3172 Indoor Unit : KMS0972 × 4 Power Supply : 230V Single Phase 60Hz < Cooling Capacity (Low Ambient...
Service Manual - Page 67

...the outdoor unit for models using the new refrigerant R410A. TEST RUN 25 NOTE 7. Inverter Multi Split System Air Conditioner - Please Read Before Starting 2 Model Combinations Combine indoor and outdoor units only as listed in its respective manual. Additional Materials Required for Installation (not supplied) 1-2. Indoor Unit 2-2. Diagram of SANYO North America Corporation...
Service Manual - Page 76

...Air intake baffle Cushion rubber Front Back Wind Air discharge baffle No air intake baffle required on the outdoor unit. (Fig. 5f) This unit is designed so that is operated at low speed when the air conditioner...bolt down unit, reducing vibration and noise. Min. 7' (2 m) 7' (2 m) Air intake Min. 6" (15 cm) Valve side Min. 10" (25 cm) Min. 2-3. When the outdoor unit is recommended ...
Service Manual - Page 94

...unit to the multi outdoor unit. Otherwise, the air conditioner may not run properly and trouble may result in trouble. At a time like this combination is not acceptable for only one of the combinations found in the 3-room operation column of Table 2. Pub. OI-85264180827002 © SANYO...outdoor unit: C=19700 (BTU/h) Rated cooling capacity of indoor units: K1, K2, ... (BTU/h) ...
Service Manual - Page 97

..., ... (BTU/h) Then: C x 2 (200%) K1 + K2 + ....... 25400 x 2 7500 + 7500 + 7500 + 17500 50800 40000 It is therefore possible to the combinations listed in the table, other combinations of Table 1. NOTE Be sure to the compressor may result in trouble. In addition to connect 4 units with respective capacities of 7500 + 7500 + 7500 + 17500. Otherwise, the air conditioner...
Service Manual - Page 98

...24200 : KMS2472 Table 1 Indoor Unit Capacity (BTU/h) Indoor Unit Combination COOLING Room Room Room Room Total Performance A B C D Capacity ( Min. - The table lists the wall-mounted type of indoor units as representative models. -2- However, all four indoor units must not be connected. Up to be operated concurrently. Otherwise, the air conditioner may be operated concurrently...
Service Manual - Page 99

Otherwise, the air conditioner may be operated concurrently. However, all four indoor units must not be connected. Max. ) Single-room Operation ...indoor units prohibited) This multi outdoor unit allows up to four indoor units to three indoor units may not run properly. Up to be operated concurrently. Voltage Rating : 208V 60Hz CLM2472 (Rated cooling capacity at 208V: 24400 BTU/h)...
Service Manual - Page 101

... ) 30600 ( 9800 - 30600 ) The table lists the wall-mounted type of operatable indoor units > Voltage Rating : 230V 60Hz CLM3172 (Rated cooling capacity at 230V: 30600 BTU/h) NOTE 7500 : KMS0772 9000 : KMS0972 11900 : KMS1272 17500 : KMS1872 24200 : KMS2472 Table 1 Indoor Unit Combination 7500 Single-room 9000 Operation 11900 17500 24200 7500 + 7500 7500 + 9000...
Service Manual - Page 102

... ( 9800 - 28600 ) The table lists the wall-mounted type of indoor units as representative models. -3- Voltage Rating : 208V 60Hz CLM3172 (Rated cooling capacity at 208V: 28600 BTU/h) NOTE 7500 : KMS0772 9000 : KMS0972 11900 : KMS1272 17500 : KMS1872 24200 : KMS2472 Table 2 Indoor Unit Combination 7500 Single-room 9000 Operation 11900 17500 24200 7500 + 7500 7500...

Similar Questions

Ask a New Question
Use the box below to post a new question about this Sanyo product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Sanyo Manuals

Find free Sanyo CLM2472 - 25,400 BTU Ductless Multi-Split Low Ambient Air Conditioner manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Sanyo Reviews

View thousands of Sanyo user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Sanyo customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Sanyo customer service rankings, employee comments and much more from our sister site.

Sanyo Recalls

Find comprehensive Sanyo recall information updated hourly on RecallOwl.com.