Planning Guides
Page 1
...) IMPORTANT: Installation of unit, end is recessed 2" (51 mm) from the cooktop is 1/2 p.s.i. When installing a backguard, use only Dacor model numbers AEB3609, AEB3612 (EG366), AEB4809 or AEB4812 (EG486). Side View cabinet/countertop Side View with the accompanying installation instructions. www....Dacor.com Phone: (800) 793-0093 4.1 Document # PG04-001 EG366, EG486 36 Inch and 48 Inch Wide Epicure® Gas Cooktops Revised 05/06/10 Page 1/4 PLANNING GUIDE...
...) IMPORTANT: Installation of unit, end is recessed 2" (51 mm) from the cooktop is 1/2 p.s.i. When installing a backguard, use only Dacor model numbers AEB3609, AEB3612 (EG366), AEB4809 or AEB4812 (EG486). Side View cabinet/countertop Side View with the accompanying installation instructions. www....Dacor.com Phone: (800) 793-0093 4.1 Document # PG04-001 EG366, EG486 36 Inch and 48 Inch Wide Epicure® Gas Cooktops Revised 05/06/10 Page 1/4 PLANNING GUIDE...
Planning Guides
Page 2
...without notice. Front View 13" (330 mm) max.3 C Hood See note 2 Model No. Specifications subject to combustible side wall Min. EG366 EG486 B 36" (914 mm) 48" (1219mm) C 36" (914 mm)* 42" (1067 mm)** 48" (1219 mm)* 54" (1372 mm)** * Minimum ** Recommended 18" (457 mm) Min.1, 3... gas and electrical service location, consult local code Revised 05/06/10 Page 2/4 PLANNING GUIDE 7 3/4" (197 mm) 36" (914 mm) typical Cabinet/Countertop Dimensions - Continued on following pages... www.Dacor.com Phone: (800) 793-0093 4.2 both sides 1/2" (13 mm) overhang, both sides B 1 1/2" (38 ...
...without notice. Front View 13" (330 mm) max.3 C Hood See note 2 Model No. Specifications subject to combustible side wall Min. EG366 EG486 B 36" (914 mm) 48" (1219mm) C 36" (914 mm)* 42" (1067 mm)** 48" (1219 mm)* 54" (1372 mm)** * Minimum ** Recommended 18" (457 mm) Min.1, 3... gas and electrical service location, consult local code Revised 05/06/10 Page 2/4 PLANNING GUIDE 7 3/4" (197 mm) 36" (914 mm) typical Cabinet/Countertop Dimensions - Continued on following pages... www.Dacor.com Phone: (800) 793-0093 4.2 both sides 1/2" (13 mm) overhang, both sides B 1 1/2" (38 ...
Planning Guides
Page 3
... places, through platform for combustible rear wall above countertop Gas connection and power cord may be routed through bottom 10" (254 mm) min. Cutout Width 36" (914 mm) 48" (1219 mm) D - EG366 EG486 B - Hole Offset 16 5/8" (422 mm) 20 13/16" (529 mm) ...Specifications subject to accompanying installation instructions. for hold down bolts 1" thick mounting platform Min. www.Dacor.com Phone: (800) 793-0093 4.3 Document # PG04-001 EG366, EG486 36 Inch and 48 Inch Wide Epicure® Gas Cooktops Cutout tolerances: +1/16", -0, (+1.6 mm, -0) unless otherwise...
... places, through platform for combustible rear wall above countertop Gas connection and power cord may be routed through bottom 10" (254 mm) min. Cutout Width 36" (914 mm) 48" (1219 mm) D - EG366 EG486 B - Hole Offset 16 5/8" (422 mm) 20 13/16" (529 mm) ...Specifications subject to accompanying installation instructions. for hold down bolts 1" thick mounting platform Min. www.Dacor.com Phone: (800) 793-0093 4.3 Document # PG04-001 EG366, EG486 36 Inch and 48 Inch Wide Epicure® Gas Cooktops Cutout tolerances: +1/16", -0, (+1.6 mm, -0) unless otherwise...
Planning Guides
Page 4
...specified. Hole Offset 16 5/8" (422 mm) 20 13/16" (529 mm) E - Cutout Width 36" (914 mm) 48" (1219 mm) D - side View Specifications subject to clear stiffener Dacor approved raised vent 3/8" Min. (10 mm) flat countertop overhang required behind raised vent chassis to change ...1105 mm) Cabinet/Countertop Cutout Dimensions with Raised Vent - Install all appliances according to allow for hold down bolts 10" (254 mm) Min. www.Dacor.com Phone: (800) 793-0093 4.4 countertop overhang Non combustible rear wall recommended 1/2" (13 mm) countertop overhang CL 24 5/8" 15" (625 ...
...specified. Hole Offset 16 5/8" (422 mm) 20 13/16" (529 mm) E - Cutout Width 36" (914 mm) 48" (1219 mm) D - side View Specifications subject to clear stiffener Dacor approved raised vent 3/8" Min. (10 mm) flat countertop overhang required behind raised vent chassis to change ...1105 mm) Cabinet/Countertop Cutout Dimensions with Raised Vent - Install all appliances according to allow for hold down bolts 10" (254 mm) Min. www.Dacor.com Phone: (800) 793-0093 4.4 countertop overhang Non combustible rear wall recommended 1/2" (13 mm) countertop overhang CL 24 5/8" 15" (625 ...
Installation Instructions
Page 7
... thickness 7 3/4" (197 mm) Cooktop platform 1" (25 mm) Min. thickness Recommended gas and electrical service location, consult local code 36" (914 mm) typical Cabinet/Countertop Dimensions - Continued on following pages... 5 Front View 13" (330 mm) max.3 C Hood See note 2 Cooktop Model ...B C EG366 36" (914 mm) 36" (914mm)* 42" (1067 mm)** EG486 48" (1219 mm) 48" (1219 mm)* 54" (1372 mm)** * Minimum ** Recommended 18" (...
... thickness 7 3/4" (197 mm) Cooktop platform 1" (25 mm) Min. thickness Recommended gas and electrical service location, consult local code 36" (914 mm) typical Cabinet/Countertop Dimensions - Continued on following pages... 5 Front View 13" (330 mm) max.3 C Hood See note 2 Cooktop Model ...B C EG366 36" (914 mm) 36" (914mm)* 42" (1067 mm)** EG486 48" (1219 mm) 48" (1219 mm)* 54" (1372 mm)** * Minimum ** Recommended 18" (...
Installation Instructions
Page 8
... Cutout 33 1/2" (851 mm) 43 1/2" (1105 mm) Approved Raised Vent Models ERV36, PRV36 ERV48, PRV48 IMPORTANT: Use only the raised vent models specified. 6 Cutout Width 36" (914 mm) 48" (1219 mm) D - for hold down bolts 1" thick mounting platform Min. Top View Cooktop Model EG366 EG486 B - Gas and electrical connections at right...
... Cutout 33 1/2" (851 mm) 43 1/2" (1105 mm) Approved Raised Vent Models ERV36, PRV36 ERV48, PRV48 IMPORTANT: Use only the raised vent models specified. 6 Cutout Width 36" (914 mm) 48" (1219 mm) D - for hold down bolts 1" thick mounting platform Min. Top View Cooktop Model EG366 EG486 B - Gas and electrical connections at right...
Use & Care Manuals
Page 4
...; Keep flammable items, such as paper, cardboard, plastic and cloth away from the rear of the cooktop to a combustible vertical surface must use Dacor backguard model AEB3609, AEB3612, ( for 36 inch models) AEB4809, AEB4812 (for 48 inch models) or a non-combustible material. • Make sure that the gas supply is disconnected. •...
...; Keep flammable items, such as paper, cardboard, plastic and cloth away from the rear of the cooktop to a combustible vertical surface must use Dacor backguard model AEB3609, AEB3612, ( for 36 inch models) AEB4809, AEB4812 (for 48 inch models) or a non-combustible material. • Make sure that the gas supply is disconnected. •...
Use & Care Manuals
Page 6
... you precise heat control from simmer to sear (high). Grate Burner Spill tray Burner control knob Trim ring SimmerSear™ Burners: Dacor's exclusive precision burner control system. Long Life Grates: The porcelain coated cast iron grates support the cooking utensils during cooking. It ... . Burner Locations A Stack Burner: 2000 - 8500 BTU B Stack Burner: 2200 - 16000 BTU C Crown Burner: 1000 - 18000 BTU EG366 - 36 Inches Wide EG486 - 48 Inches Wide 4 With Perma-Flame, your cooking experience is uninterrupted because the flame is on the burners and adjust the flame...
... you precise heat control from simmer to sear (high). Grate Burner Spill tray Burner control knob Trim ring SimmerSear™ Burners: Dacor's exclusive precision burner control system. Long Life Grates: The porcelain coated cast iron grates support the cooking utensils during cooking. It ... . Burner Locations A Stack Burner: 2000 - 8500 BTU B Stack Burner: 2200 - 16000 BTU C Crown Burner: 1000 - 18000 BTU EG366 - 36 Inches Wide EG486 - 48 Inches Wide 4 With Perma-Flame, your cooking experience is uninterrupted because the flame is on the burners and adjust the flame...