Planning Guides
Page 1
...is 1/2 p.s.i. Side View cabinet/countertop Side View with the accompanying installation instructions. Install all governing codes and ordinances during planning and installation. www.Dacor.com Phone: (800) 793-0093 4.1 Width 35 7/8" (911 mm) 47 7/8" (1216 mm) IMPORTANT: Installation of unit, end is less... recommended, and mandatory if the distance to the back wall from the cooktop is recessed 2" (51 mm) from chassis bottom Product Dimensions - A Product Dimensions - Combustible rear wall 2 1/2" (64 mm) Min. Document # PG04-001 EG366, EG486 36 Inch and 48 Inch Wide Epicure...
...is 1/2 p.s.i. Side View cabinet/countertop Side View with the accompanying installation instructions. Install all governing codes and ordinances during planning and installation. www.Dacor.com Phone: (800) 793-0093 4.1 Width 35 7/8" (911 mm) 47 7/8" (1216 mm) IMPORTANT: Installation of unit, end is less... recommended, and mandatory if the distance to the back wall from the cooktop is recessed 2" (51 mm) from chassis bottom Product Dimensions - A Product Dimensions - Combustible rear wall 2 1/2" (64 mm) Min. Document # PG04-001 EG366, EG486 36 Inch and 48 Inch Wide Epicure...
Planning Guides
Page 2
... local code Revised 05/06/10 Page 2/4 PLANNING GUIDE 7 3/4" (197 mm) 36" (914 mm) typical Cabinet/Countertop Dimensions - Top View 3 Not applicable for utility access Cabinet/Countertop Dimensions ISO View 1 Vertical to change without notice. EG366, EG486 Document # PG04-001 36 Inch and 48 Inch Wide Epicure®... (25 mm) Min. if installing an overhead vent hood, also check the hood specifications for minimum required clearances. 2 See Cabinet/Countertop Dimensions - Specifications subject to combustible surface from the edge of 10" (254mm) from cooktop grate level; www...
... local code Revised 05/06/10 Page 2/4 PLANNING GUIDE 7 3/4" (197 mm) 36" (914 mm) typical Cabinet/Countertop Dimensions - Top View 3 Not applicable for utility access Cabinet/Countertop Dimensions ISO View 1 Vertical to change without notice. EG366, EG486 Document # PG04-001 36 Inch and 48 Inch Wide Epicure®... (25 mm) Min. if installing an overhead vent hood, also check the hood specifications for minimum required clearances. 2 See Cabinet/Countertop Dimensions - Specifications subject to combustible surface from the edge of 10" (254mm) from cooktop grate level; www...
Planning Guides
Page 3
for hold down bolts 1" thick mounting platform Min. www.Dacor.com Phone: (800) 793-0093 4.3 D D CL CL B 2" (51 mm) 1" (25 mm) Cabinet face below countertop CL overhang Cabinet/Countertop Cutout Dimensions without notice. Top View Model No. to combustible wall above countertop, both sides 1/2" (13 mm) countertop overhang Countertop Hole 1/2" dia. (13 mm...
for hold down bolts 1" thick mounting platform Min. www.Dacor.com Phone: (800) 793-0093 4.3 D D CL CL B 2" (51 mm) 1" (25 mm) Cabinet face below countertop CL overhang Cabinet/Countertop Cutout Dimensions without notice. Top View Model No. to combustible wall above countertop, both sides 1/2" (13 mm) countertop overhang Countertop Hole 1/2" dia. (13 mm...
Planning Guides
Page 4
... IMPORTANT: Use only the raised vents specified. Model No. www.Dacor.com Phone: (800) 793-0093 4.4 Top View Stiffener 3/8" Min. (10 mm) space behind raised vent chassis to below countertop overhang B Cabinet/Countertop Cutout Dimensions with Raised Vent - Hole 1/2" dia. (13 mm), 2 ... Minimum countertop height: 30 1/4" (768 mm) Model No. Raised Vent Cutout 33 1/2" (851 mm) 43 1/2" (1105 mm) Cabinet/Countertop Cutout Dimensions with Raised Vent - countertop overhang Non combustible rear wall recommended 1/2" (13 mm) countertop overhang CL 24 5/8" 15" (625 mm) (381 mm...
... IMPORTANT: Use only the raised vents specified. Model No. www.Dacor.com Phone: (800) 793-0093 4.4 Top View Stiffener 3/8" Min. (10 mm) space behind raised vent chassis to below countertop overhang B Cabinet/Countertop Cutout Dimensions with Raised Vent - Hole 1/2" dia. (13 mm), 2 ... Minimum countertop height: 30 1/4" (768 mm) Model No. Raised Vent Cutout 33 1/2" (851 mm) 43 1/2" (1105 mm) Cabinet/Countertop Cutout Dimensions with Raised Vent - countertop overhang Non combustible rear wall recommended 1/2" (13 mm) countertop overhang CL 24 5/8" 15" (625 mm) (381 mm...
Installation Instructions
Page 2
... General Safety Precautions 2 Installation Requirements 3 Electrical Requirements 3 Gas Supply Requirements 3 Product Dimensions 3 Cabinet and Countertop Layout 4 Cabinet/Cutout Dimensions 5 Installation Instructions 8 Cooktop Installation 8 Gas Line Connection 9 Burner Component Installation 10 ...Keep these installation instructions with installation, contact your Dacor ® dealer or the Dacor Customer Service Team. Friday 6:00 a.m. Customer Service Information If You Need Help... to 4:00 p.m. Model Identification EG366SCH/NG/H SIZE (in inches) GAS TYPE ...
... General Safety Precautions 2 Installation Requirements 3 Electrical Requirements 3 Gas Supply Requirements 3 Product Dimensions 3 Cabinet and Countertop Layout 4 Cabinet/Cutout Dimensions 5 Installation Instructions 8 Cooktop Installation 8 Gas Line Connection 9 Burner Component Installation 10 ...Keep these installation instructions with installation, contact your Dacor ® dealer or the Dacor Customer Service Team. Friday 6:00 a.m. Customer Service Information If You Need Help... to 4:00 p.m. Model Identification EG366SCH/NG/H SIZE (in inches) GAS TYPE ...
Installation Instructions
Page 5
... installed in accordance with National Electric Code ANSI/NFPA 70 and local codes and ordinances. The regulator inlet accommodates a 3/4" gas supply line and is 1/2 p.s.i. Product Dimensions 28" (711 mm) 27" (686 mm) 26" (660 mm) Trim: 7/16" (11 mm) thick A COOKTOP WIDTH (A) EG366 35 7/8" (911 mm) EG486 47 7/8" (1216 mm) 1 1/2" (38...
... installed in accordance with National Electric Code ANSI/NFPA 70 and local codes and ordinances. The regulator inlet accommodates a 3/4" gas supply line and is 1/2 p.s.i. Product Dimensions 28" (711 mm) 27" (686 mm) 26" (660 mm) Trim: 7/16" (11 mm) thick A COOKTOP WIDTH (A) EG366 35 7/8" (911 mm) EG486 47 7/8" (1216 mm) 1 1/2" (38...
Installation Instructions
Page 7
... the hood specifications for cabinets more than a horizontal distance of 10" (254mm) from cooktop grate level; Installation Requirements Cabinet/Cutout Dimensions Cabinet tolerances +1/16" -0 (+1.6 mm, 0) unless otherwise noted. 10" (254 mm) to combustible surface from the edge of... finished counter Cutout for utility access Cabinet/Countertop Dimensions ISO View 1 Vertical to combustible side wall Min. both sides 1/2" (13 mm) overhang, both sides B 1 1/2" (38 mm) typical countertop ...
... the hood specifications for cabinets more than a horizontal distance of 10" (254mm) from cooktop grate level; Installation Requirements Cabinet/Cutout Dimensions Cabinet tolerances +1/16" -0 (+1.6 mm, 0) unless otherwise noted. 10" (254 mm) to combustible surface from the edge of... finished counter Cutout for utility access Cabinet/Countertop Dimensions ISO View 1 Vertical to combustible side wall Min. both sides 1/2" (13 mm) overhang, both sides B 1 1/2" (38 mm) typical countertop ...
Installation Instructions
Page 8
... Width 36" (914 mm) 48" (1219 mm) D - D D CL CL B 2" (51 mm) 1" (25 mm) Cabinet face CL below countertop overhang Cabinet/Countertop Cutout Dimensions without Raised Vent - Hole Offset 16 5/8" (422 mm) 20 13/16" (529 mm) E - for combustible rear wall above countertop, both sides 1/2" (13 mm) countertop overhang... 6" D (203 mm X 152 mm), if gas and electrical are routed through platform for hold down bolts 1" thick mounting platform Min. Installation Requirements Cabinet/Countertop Dimensions (cont.) Cutout tolerances +1/16" -0 (+1.6 mm, 0) unless otherwise noted.
... Width 36" (914 mm) 48" (1219 mm) D - D D CL CL B 2" (51 mm) 1" (25 mm) Cabinet face CL below countertop overhang Cabinet/Countertop Cutout Dimensions without Raised Vent - Hole Offset 16 5/8" (422 mm) 20 13/16" (529 mm) E - for combustible rear wall above countertop, both sides 1/2" (13 mm) countertop overhang... 6" D (203 mm X 152 mm), if gas and electrical are routed through platform for hold down bolts 1" thick mounting platform Min. Installation Requirements Cabinet/Countertop Dimensions (cont.) Cutout tolerances +1/16" -0 (+1.6 mm, 0) unless otherwise noted.
Installation Instructions
Page 9
Hole 1/2" dia. (13 mm), 2 places, through the bottom of the cooktop when installed with Raised Vent - Cabinet/Countertop Cutout Dimensions with a raised vent. Side View 7 to combustible wall above countertop, both sides 1/2" (13 mm) countertop overhang Countertop Countertop 2" (51 mm) 1" (25 mm...recommended 1/2" (13 mm) countertop overhang CL 24 5/8" 15" (625 mm) (381 mm) 11 7/16" (291 mm) E Open to clear stiffener Dacor approved raised vent EG366 or EG486 cooktop Control panel Cabinet face IMPORTANT: See raised vent installation instructions for hold down bolts 10" (254 mm) Min...
Hole 1/2" dia. (13 mm), 2 places, through the bottom of the cooktop when installed with Raised Vent - Cabinet/Countertop Cutout Dimensions with a raised vent. Side View 7 to combustible wall above countertop, both sides 1/2" (13 mm) countertop overhang Countertop Countertop 2" (51 mm) 1" (25 mm...recommended 1/2" (13 mm) countertop overhang CL 24 5/8" 15" (625 mm) (381 mm) 11 7/16" (291 mm) E Open to clear stiffener Dacor approved raised vent EG366 or EG486 cooktop Control panel Cabinet face IMPORTANT: See raised vent installation instructions for hold down bolts 10" (254 mm) Min...