Fluke 1520 MegOhmMeter Datasheet
Page 1
Fluke 1520 MegOhmMeter Technical Data The Fluke 1520 MegOhmMeter is greater than 30V ac or 30V dc. • AC/DC voltage measurement up to 600V • Lo-Ohms function for testing connections • Last reading memory display • 4 C-cell batteries for insulation resistance testing: 250V, 500V, 1000V • Insulation resistance...) 2% + 2 counts 1V 0 to 4000 MΩ; switches automatically to voltage measurement when voltage is a handy insulation resistance tester that also measures voltage and checks connections with its Lo-Ohms function. • Large, backlit LCD with analog...
Fluke 1520 MegOhmMeter Technical Data The Fluke 1520 MegOhmMeter is greater than 30V ac or 30V dc. • AC/DC voltage measurement up to 600V • Lo-Ohms function for testing connections • Last reading memory display • 4 C-cell batteries for insulation resistance testing: 250V, 500V, 1000V • Insulation resistance...) 2% + 2 counts 1V 0 to 4000 MΩ; switches automatically to voltage measurement when voltage is a handy insulation resistance tester that also measures voltage and checks connections with its Lo-Ohms function. • Large, backlit LCD with analog...
FE 1520 Users Manual
Page 6
The MegOhmMeter includes the following items, see Figure 1: • 2 test leads, red and black, 1.5 m • 2 test probes, red and black • 2 alligator clips, red and black • Hand strap • Carrying case • CD ROM (Not Pictured) 1 Fluke 1520 Unpacking the Meter The Fluke Model 1520 MegOhmMeter (hereafter, "the meter") is a handheld instrument designed primarily to make resistance/insulation resistance measurements.
The MegOhmMeter includes the following items, see Figure 1: • 2 test leads, red and black, 1.5 m • 2 test probes, red and black • 2 alligator clips, red and black • Hand strap • Carrying case • CD ROM (Not Pictured) 1 Fluke 1520 Unpacking the Meter The Fluke Model 1520 MegOhmMeter (hereafter, "the meter") is a handheld instrument designed primarily to make resistance/insulation resistance measurements.
FE 1520 Users Manual
Page 18
... display shows the resistance. Select the test voltage. 2. The upper left display shows the test voltage applied to be measured. until the TEST button is present. Connect the probes to the circuit to the circuit under test before proceeding with the next step. MegOhmMeter Using the Meter To measure insulation resistance, do the following...
... display shows the resistance. Select the test voltage. 2. The upper left display shows the test voltage applied to be measured. until the TEST button is present. Connect the probes to the circuit to the circuit under test before proceeding with the next step. MegOhmMeter Using the Meter To measure insulation resistance, do the following...
FE 1520 Users Manual
Page 20
... hold the TEST button. MegOhmMeter Using the Meter Using the LOCK Function to disengage the lock function. 15 In this mode a potentially dangerous voltage is live. Press the TEST button, then press the LOCK button, and then release both simultaneously. Press LOCK or TEST to Measure Insulation Resistance The LOCK function holds the...
... hold the TEST button. MegOhmMeter Using the Meter Using the LOCK Function to disengage the lock function. 15 In this mode a potentially dangerous voltage is live. Press the TEST button, then press the LOCK button, and then release both simultaneously. Press LOCK or TEST to Measure Insulation Resistance The LOCK function holds the...
FE 1520 Users Manual
Page 36
MegOhmMeter Specifications Electrical Specifications Battery C Size 1.5 V alkaline, ANSI/NEDA-14A, IECLR14 (4 pieces) Fuse 6 mm x 32 mm (0.25 x 1.25 inch), 0.5 A 660 V, Fast Acting, 50 A Minimum Interrupt rating Insulation Resistance Display Ranges Measurement Range (per EN61557-2) Resolution Accuracy Analog Bar Graph 4.000 MΩ, 40.00 MΩ, 400.0 MΩ, 4000 MΩ 0.250 MΩ to 4000 MΩ 0.001 MΩ to 10 MΩ 2 % + 2 counts 0.250 MΩ to 100.0 MΩ 10 % + 2 counts + 1 %/1000 MΩ 100.0 MΩ to 4000 MΩ 0 to ∞ 31
MegOhmMeter Specifications Electrical Specifications Battery C Size 1.5 V alkaline, ANSI/NEDA-14A, IECLR14 (4 pieces) Fuse 6 mm x 32 mm (0.25 x 1.25 inch), 0.5 A 660 V, Fast Acting, 50 A Minimum Interrupt rating Insulation Resistance Display Ranges Measurement Range (per EN61557-2) Resolution Accuracy Analog Bar Graph 4.000 MΩ, 40.00 MΩ, 400.0 MΩ, 4000 MΩ 0.250 MΩ to 4000 MΩ 0.001 MΩ to 10 MΩ 2 % + 2 counts 0.250 MΩ to 100.0 MΩ 10 % + 2 counts + 1 %/1000 MΩ 100.0 MΩ to 4000 MΩ 0 to ∞ 31