HP SureStore E Disk System SC10 User and Service Guide
Page 33
Installation (HP-Qualified Only) 2 INSTALLATION (HP-QUALIFIED ONLY) Preparation Step 1: Gather Tools Step 2: Unpack the Product Step 3: Install Rails Step 4: Prepare Rack Front Step 5: Install the Disk System Step 6: Install BCCs Step 7: Set DIP Switches Step 8: Connect SCSI and Power Cables Step 9: Install Disks Step 10: Turn on the Disk System Step 11: Verify Devices on the Host 33
Installation (HP-Qualified Only) 2 INSTALLATION (HP-QUALIFIED ONLY) Preparation Step 1: Gather Tools Step 2: Unpack the Product Step 3: Install Rails Step 4: Prepare Rack Front Step 5: Install the Disk System Step 6: Install BCCs Step 7: Set DIP Switches Step 8: Connect SCSI and Power Cables Step 9: Install Disks Step 10: Turn on the Disk System Step 11: Verify Devices on the Host 33
HP SureStore E Disk System SC10 User and Service Guide
Page 58
Even without the help of another person or a lift device. WARNING Do not attempt to lift the disk system using the power supply handles. Step 5: Install the Disk System Caution Do not try to lift the disk system without power supplies and disk drives, the disk system weighs 50 pounds. 58
Even without the help of another person or a lift device. WARNING Do not attempt to lift the disk system using the power supply handles. Step 5: Install the Disk System Caution Do not try to lift the disk system without power supplies and disk drives, the disk system weighs 50 pounds. 58
HP SureStore E Disk System SC10 User and Service Guide
Page 65
Note 65 If settings differ, the disk system will not spin up. Installation (HP-Qualified Only) Step 7: Set DIP Switches Caution DIP switch settings must be the same on self-test and disks will fail its power-on both BCCs.
Note 65 If settings differ, the disk system will not spin up. Installation (HP-Qualified Only) Step 7: Set DIP Switches Caution DIP switch settings must be the same on self-test and disks will fail its power-on both BCCs.
HP SureStore E Disk System SC10 User and Service Guide
Page 73
...: Verify Devices on the Host Installation (HP-Qualified Only) ctl Class I H/W Path Driver S/W State H/W Type Description bc 0 root CLAIMED BUS_NEXUS bc 18 bc CLAIMED BUS_NEXUS Pseudo Bus Converter ba 0 8/0 GSCtoPCI CLAIMED BUS_NEXUS PCI Bus Bridge-GSCtoPCI ext_bus 0 8/0/1/0 c720 CLAIMED INTERFACE Ultra2 Wide SCSI target 0 8/0/1/0.0 tgt CLAIMED DEVICE disk 1 8/0/1/0.0.0 sdisk CLAIMED DEVICE SEAGATE ST118202LC target 1 8/0/1/0.1 tgt CLAIMED DEVICE disk 2 8/0/1/0.1.0 sdisk CLAIMED DEVICE SEAGATE ST118202LC target 2 8/0/1/0.2 tgt CLAIMED DEVICE disk...
...: Verify Devices on the Host Installation (HP-Qualified Only) ctl Class I H/W Path Driver S/W State H/W Type Description bc 0 root CLAIMED BUS_NEXUS bc 18 bc CLAIMED BUS_NEXUS Pseudo Bus Converter ba 0 8/0 GSCtoPCI CLAIMED BUS_NEXUS PCI Bus Bridge-GSCtoPCI ext_bus 0 8/0/1/0 c720 CLAIMED INTERFACE Ultra2 Wide SCSI target 0 8/0/1/0.0 tgt CLAIMED DEVICE disk 1 8/0/1/0.0.0 sdisk CLAIMED DEVICE SEAGATE ST118202LC target 1 8/0/1/0.1 tgt CLAIMED DEVICE disk 2 8/0/1/0.1.0 sdisk CLAIMED DEVICE SEAGATE ST118202LC target 2 8/0/1/0.2 tgt CLAIMED DEVICE disk...
HP SureStore E Disk System SC10 User and Service Guide
Page 75
3 Setting DIP Switches Disk Addressing Setting Up the Hardware Event Monitor Annotating Devices (HP-Qualified Only) Updating Firmware (HP-Qualified Only) CONFIGURATION Configuration 75
3 Setting DIP Switches Disk Addressing Setting Up the Hardware Event Monitor Annotating Devices (HP-Qualified Only) Updating Firmware (HP-Qualified Only) CONFIGURATION Configuration 75
HP SureStore E Disk System SC10 User and Service Guide
Page 76
Setting DIP Switches Switch 1 Full Bus 2 JBOD 3 Bus Reset: Pwr Fail 4 Address High 5 Bus Reset: Hot Swap ON = | OFF = 0 Creates a single bus of 10 addresses Sets disk-to-host configuration Splits the bus into two buses, 5 addresses each For use with array product Automatically resets the bus when Lets the host detect change and power fails determine action Assigns high SCSI addresses (8-12) to disks on split bus Assigns low SCSI addresses (0-3, 13) to disks on split bus Automatically resets the...
Setting DIP Switches Switch 1 Full Bus 2 JBOD 3 Bus Reset: Pwr Fail 4 Address High 5 Bus Reset: Hot Swap ON = | OFF = 0 Creates a single bus of 10 addresses Sets disk-to-host configuration Splits the bus into two buses, 5 addresses each For use with array product Automatically resets the bus when Lets the host detect change and power fails determine action Assigns high SCSI addresses (8-12) to disks on split bus Assigns low SCSI addresses (0-3, 13) to disks on split bus Automatically resets the...
HP SureStore E Disk System SC10 User and Service Guide
Page 77
...-bus mode uses fewer IDs on the bus. 5. Bus ResetPwr Fail Automatic bus reset reduces the chances of data corruption and saves the 30 to 60 seconds that the host would spend determining that a disk is restricted to access all ten disks with two BCCs gives redundant environmental services. devices on the bus, improving bus performance. 2. Split buses allow you to Set OFF...
...-bus mode uses fewer IDs on the bus. 5. Bus ResetPwr Fail Automatic bus reset reduces the chances of data corruption and saves the 30 to 60 seconds that the host would spend determining that a disk is restricted to access all ten disks with two BCCs gives redundant environmental services. devices on the bus, improving bus performance. 2. Split buses allow you to Set OFF...
HP SureStore E Disk System SC10 User and Service Guide
Page 85
4 TROUBLESHOOTING Overview Event Notification Status LEDs Using STM to View Status and Flash LEDs Isolating Faults Troubleshooting 85
4 TROUBLESHOOTING Overview Event Notification Status LEDs Using STM to View Status and Flash LEDs Isolating Faults Troubleshooting 85
HP SureStore E Disk System SC10 User and Service Guide
Page 88
... /storage/events/enclosures/ses_enclosure/8_0_1_0.15.0 is MAJORWARNING(3) Event data from monitor: Event Time: Wed Feb 3 11:27:15 1999 Hostname: yourserver.rose.hp.com Event ID: 0x0036b8a313000000002 Event # : 402 Severity : MAJOR WARNING IP Address : 15.43.213.13 Monitor : dm_ses_enclosure Event Class: I/O Enclosure at hardware path 8/0/1/0.15.0: Hardware failure Associated OS error log entry id(s): None Description of Error: The enclosure services controllers have different versions of firmware. Its current value is >=1. Update the controllers to the same version of firmware...
... /storage/events/enclosures/ses_enclosure/8_0_1_0.15.0 is MAJORWARNING(3) Event data from monitor: Event Time: Wed Feb 3 11:27:15 1999 Hostname: yourserver.rose.hp.com Event ID: 0x0036b8a313000000002 Event # : 402 Severity : MAJOR WARNING IP Address : 15.43.213.13 Monitor : dm_ses_enclosure Event Class: I/O Enclosure at hardware path 8/0/1/0.15.0: Hardware failure Associated OS error log entry id(s): None Description of Error: The enclosure services controllers have different versions of firmware. Its current value is >=1. Update the controllers to the same version of firmware...
HP SureStore E Disk System SC10 User and Service Guide
Page 90
... switch settings do not match. LED System Power System Fault BCC Fault LVD Term. Full Bus Bus Active Fan State Green OFF Amber OFF Flashing Amber OFF Flashing Green OFF Green OFF Green OFF Green OFF Amber Green OFF Indication Power is available from the host. There is not available. Start-up1 / Fault Normal operation Power is off Self-test1 / Problem2 Normal operation BCC A & B DIP switch settings do not match Bus operating in LVD mode Bus operating...
... switch settings do not match. LED System Power System Fault BCC Fault LVD Term. Full Bus Bus Active Fan State Green OFF Amber OFF Flashing Amber OFF Flashing Green OFF Green OFF Green OFF Green OFF Amber Green OFF Indication Power is available from the host. There is not available. Start-up1 / Fault Normal operation Power is off Self-test1 / Problem2 Normal operation BCC A & B DIP switch settings do not match Bus operating in LVD mode Bus operating...
HP SureStore E Disk System SC10 User and Service Guide
Page 94
Information Tool Log for Disk Enclosure on path 8/0/1/0.15.0 .... The disk slot status reporting is not available. A: B: Status OK OK (Reporting Controller) Fan Modules ----------- Controllers ----------- The disk device status is owned by the peer controller. Information Tool Log for Disk Enclosure on path 8/0/1/0.15.0 -- A: B: Status OK OK 94 swerve.rose.hp.com : 15.43.213.13 .... -- Log creation time: Wed Feb 24 13:10:40 1999 Hardware path: 8/0/1/0.15.0 Product ID: A5272A Controller B Hardware Path: 8/0/1/0.15.0 Serial No: R8CGC1128471 Firmware Rev.: HP01...
Information Tool Log for Disk Enclosure on path 8/0/1/0.15.0 .... The disk slot status reporting is not available. A: B: Status OK OK (Reporting Controller) Fan Modules ----------- Controllers ----------- The disk device status is owned by the peer controller. Information Tool Log for Disk Enclosure on path 8/0/1/0.15.0 -- A: B: Status OK OK 94 swerve.rose.hp.com : 15.43.213.13 .... -- Log creation time: Wed Feb 24 13:10:40 1999 Hardware path: 8/0/1/0.15.0 Product ID: A5272A Controller B Hardware Path: 8/0/1/0.15.0 Serial No: R8CGC1128471 Firmware Rev.: HP01...
HP SureStore E Disk System SC10 User and Service Guide
Page 96
... firmware versions. Component is installed without known errors, but has not been turned on or set into operation; Voltage/ N/A temperature exceeds critical limit. or the controller that owns reporting has failed. Unknown Not Available Owned by peer controller. 96 Reporting is N/A N/A N/A N/A owned by Peer Controller N/A N/A N/A Sensor has failed or status is installed and no error conditions are known. Voltage/ N/A temperature exceeds warning limit. Component/ Status Disks BCCs Fans, Power Supplies...
... firmware versions. Component is installed without known errors, but has not been turned on or set into operation; Voltage/ N/A temperature exceeds critical limit. or the controller that owns reporting has failed. Unknown Not Available Owned by peer controller. 96 Reporting is N/A N/A N/A N/A owned by Peer Controller N/A N/A N/A Sensor has failed or status is installed and no error conditions are known. Voltage/ N/A temperature exceeds warning limit. Component/ Status Disks BCCs Fans, Power Supplies...
HP SureStore E Disk System SC10 User and Service Guide
Page 99
... Critical BCC Fault Critical on A component has failed. Power supply LED off . Neither power cord is amber HW Event LED Category State STM Status Probable Cause/Solution none none Critical none System none power LED off - BCC Fault Disk Not BCC DIP switch settings do not match peer flashing Available BCC switch settings. Isolating Faults Problem Description Installed product does not power on System fault LED is on Audio alarm when BCC installed BCC Fault LED is on Fan LED is plugged in . Reset switches.
... Critical BCC Fault Critical on A component has failed. Power supply LED off . Neither power cord is amber HW Event LED Category State STM Status Probable Cause/Solution none none Critical none System none power LED off - BCC Fault Disk Not BCC DIP switch settings do not match peer flashing Available BCC switch settings. Isolating Faults Problem Description Installed product does not power on System fault LED is on Audio alarm when BCC installed BCC Fault LED is on Fan LED is plugged in . Reset switches.
HP SureStore E Disk System SC10 User and Service Guide
Page 100
... Event LED Description Category State STM Status Probable Cause/Solution Power supply Critical LED is >36º C - IOSCAN lists BCC and disks as NO_HW On or off . Check status and correct any problem. Disk system is powered off none - IOSCAN lists none disk as NO_HW Critical All normal none All off . Temperature Critical is over limit none Major none Warning Critical Temp is >54.5º C Noncritical Temp is amber Amber...
... Event LED Description Category State STM Status Probable Cause/Solution Power supply Critical LED is >36º C - IOSCAN lists BCC and disks as NO_HW On or off . Check status and correct any problem. Disk system is powered off none - IOSCAN lists none disk as NO_HW Critical All normal none All off . Temperature Critical is over limit none Major none Warning Critical Temp is >54.5º C Noncritical Temp is amber Amber...
HP SureStore E Disk System SC10 User and Service Guide
Page 103
Removal and Replacement 5 REMOVAL AND REPLACEMENT Disk BCC Fan Power Supply Disk System Door Top Cover (HP-Qualified Only) Backplane/Mezzanine (HP-Qualified Only) Disk Carrier (HP-Qualified Only) 103
Removal and Replacement 5 REMOVAL AND REPLACEMENT Disk BCC Fan Power Supply Disk System Door Top Cover (HP-Qualified Only) Backplane/Mezzanine (HP-Qualified Only) Disk Carrier (HP-Qualified Only) 103
HP SureStore E Disk System SC10 User and Service Guide
Page 147
... in a typical configuration with or without suffixes. Model A180. Roseville, May 6 ,th 1999. Roseville, CA 95747 USA SureStore E Disk System SC10. All conforms to ISO/IEC Guide 22 and EN 45014 Hewlett-Packard Company Enterprise Storage Solutions Division 8000 Foothills Blvd. A5272 & A5294 with the HP 9000 Class A Server - European Contact: Your local Hewlett-Packard Sales and Service Office or Hewlett...
... in a typical configuration with or without suffixes. Model A180. Roseville, May 6 ,th 1999. Roseville, CA 95747 USA SureStore E Disk System SC10. All conforms to ISO/IEC Guide 22 and EN 45014 Hewlett-Packard Company Enterprise Storage Solutions Division 8000 Foothills Blvd. A5272 & A5294 with the HP 9000 Class A Server - European Contact: Your local Hewlett-Packard Sales and Service Office or Hewlett...
ISS Technology Focus, Number 14
Page 1
... technology brief "Solid state storage technology for enterprise server storage. MLC technology is a primary factor. SLC-based SSDs provide the highest performance and endurance for ProLiant servers" at 100% writes. Follow us: Like us: Choose the right solid-state storage solution This article describes the features and applications of DC vs. AC power supplies » Tip: Check HyperThreading status remotely using Microsoft® Windows® PowerShell...
... technology brief "Solid state storage technology for enterprise server storage. MLC technology is a primary factor. SLC-based SSDs provide the highest performance and endurance for ProLiant servers" at 100% writes. Follow us: Like us: Choose the right solid-state storage solution This article describes the features and applications of DC vs. AC power supplies » Tip: Check HyperThreading status remotely using Microsoft® Windows® PowerShell...
ISS Technology Focus, Number 14
Page 2
...-of different applications shown in some cases. SmartSSD Wear Gauge support All HP SSDs incorporate sophisticated features to 1000G. These monitoring features enable tools that if the drive loses power (including hot plug removal), user data in write cache still writes to the drive and the drive can be ready in particular environments. Like other storage volumes. Our portfolio consists of four classes of SSD for...
...-of different applications shown in some cases. SmartSSD Wear Gauge support All HP SSDs incorporate sophisticated features to 1000G. These monitoring features enable tools that if the drive loses power (including hot plug removal), user data in write cache still writes to the drive and the drive can be ready in particular environments. Like other storage volumes. Our portfolio consists of four classes of SSD for...
ISS Technology Focus, Number 14
Page 4
... enabled by as the HP Gold and Platinum Common Slot Power Supplies, achieve efficiencies that include NumberOfLogicalProcessors and NumberOfCores. The most common options are: • Reboot each server and check the HT status through the ROM Based Setup Utility (RBSU). A better way to the server components, which is a socket with properties that reach or exceed 90%. PowerShell provides full access to Windows Management Instrumentation (WMI), enabling...
... enabled by as the HP Gold and Platinum Common Slot Power Supplies, achieve efficiencies that include NumberOfLogicalProcessors and NumberOfCores. The most common options are: • Reboot each server and check the HT status through the ROM Based Setup Utility (RBSU). A better way to the server components, which is a socket with properties that reach or exceed 90%. PowerShell provides full access to Windows Management Instrumentation (WMI), enabling...
ISS Technology Focus, Number 14
Page 5
...; Configuring HP Integrated Lights-Out 3 with Microsoft Active Directory HOWTO, 2nd edition » Serial Attached SCSI technologies and architectures, 4th edition » HP Insight Control for technical or editorial errors or omissions contained herein. If you would like to discontinue receiving these types of virtualization and cloud computing on data center networks » Optimizing GPU-based application performance for the HP for HP products and services are set...
...; Configuring HP Integrated Lights-Out 3 with Microsoft Active Directory HOWTO, 2nd edition » Serial Attached SCSI technologies and architectures, 4th edition » HP Insight Control for technical or editorial errors or omissions contained herein. If you would like to discontinue receiving these types of virtualization and cloud computing on data center networks » Optimizing GPU-based application performance for the HP for HP products and services are set...