User Guide
Page 3
...documents that require special handling 3-11 Calibrating the scanner 3-11 Image calibration 3-12 Ultrasonics calibration 3-15 4 The Enhanced Printer 4-1 Overview 4-1 Printer specifications 4-2 Accessing the Enhanced Printer 4-3 Changing the printer position 4-4 Replacing the ink cartridge 4-4 Replacing the blotter strips 4-6 Replacing the ink cartridge carrier 4-7 5 Maintenance...6-1 Accessing the Operator Log 6-3 i600 Series Scanners Message listing 6-6 i600 Series Scanners Numerical Message listing 6-11 i700 Series Scanners Message listing 6-12 i700 Series Scanenrs Numerial ...
...documents that require special handling 3-11 Calibrating the scanner 3-11 Image calibration 3-12 Ultrasonics calibration 3-15 4 The Enhanced Printer 4-1 Overview 4-1 Printer specifications 4-2 Accessing the Enhanced Printer 4-3 Changing the printer position 4-4 Replacing the ink cartridge 4-4 Replacing the blotter strips 4-6 Replacing the ink cartridge carrier 4-7 5 Maintenance...6-1 Accessing the Operator Log 6-3 i600 Series Scanners Message listing 6-6 i600 Series Scanners Numerical Message listing 6-11 i700 Series Scanners Message listing 6-12 i700 Series Scanenrs Numerial ...
User Guide
Page 4
..., safety information and user precautions. provides maintenance procedures for the Kodak i600/i700 Series Scanners, including replacement procedures for using these accessories are included with all of the specifications for scanning, document feeder and output tray adjustments, scanner calibration and how to prepare your documents for the Kodak i600/i700 Series Scanners. Chapter 6, Troubleshooting - Chapter 2, Getting Started - Appendix...
..., safety information and user precautions. provides maintenance procedures for the Kodak i600/i700 Series Scanners, including replacement procedures for using these accessories are included with all of the specifications for scanning, document feeder and output tray adjustments, scanner calibration and how to prepare your documents for the Kodak i600/i700 Series Scanners. Chapter 6, Troubleshooting - Chapter 2, Getting Started - Appendix...
User Guide
Page 27
...and clean the imaging guides. If the lamps have not been on your scanner. Select Kodak Scanner: i600 or Kodak Scanner: i700. Place the calibration target in the elevator tray and output tray. 4. The main Kodak Scanner window will be ordered. Additional calibration targets can be displayed. 3-12 A-... information. Refer to use a good, clean calibration target. Center the side guides in the elevator tray. 5. Be sure to the maintenance procedures in this section are for 90 seconds. 3. Image calibration Use the calibration target provided with your system may be different. 1....
...and clean the imaging guides. If the lamps have not been on your scanner. Select Kodak Scanner: i600 or Kodak Scanner: i700. Place the calibration target in the elevator tray and output tray. 4. The main Kodak Scanner window will be ordered. Additional calibration targets can be displayed. 3-12 A-... information. Refer to use a good, clean calibration target. Center the side guides in the elevator tray. 5. Be sure to the maintenance procedures in this section are for 90 seconds. 3. Image calibration Use the calibration target provided with your system may be different. 1....
User Guide
Page 39
...-accessible parts. Following this manual. Some document types generate more paper dust and debris and may require more frequent cleaning than recommended. Do not use air, liquid or gas spray cleaners. Cleaning your scanner and preventative maintenance on the feed module and separation roller ..., dirt or debris to another location within the scanner, which could cause the scanner to malfunction. • Some debris from the rubber tires on a regular basis is recommended to ensure the best possible image quality. NOTES: • Follow the recommended Kodak cleaning procedures.
...-accessible parts. Following this manual. Some document types generate more paper dust and debris and may require more frequent cleaning than recommended. Do not use air, liquid or gas spray cleaners. Cleaning your scanner and preventative maintenance on the feed module and separation roller ..., dirt or debris to another location within the scanner, which could cause the scanner to malfunction. • Some debris from the rubber tires on a regular basis is recommended to ensure the best possible image quality. NOTES: • Follow the recommended Kodak cleaning procedures.
User Guide
Page 40
... frequently you should clean your scanner. • Kodak Digital Science Transport Cleaning Sheets • Kodak Digital Science Roller Cleaning Pads • Staticide Wipes for Kodak Scanners • A vacuum cleaner and tools 5-2 A-61500 April 2009 Use of new shift shift x x x x x x x x Use only these cleaning tools and materials when performing routine maintenance on your scanner. Procedure Vacuum output tray...
... frequently you should clean your scanner. • Kodak Digital Science Transport Cleaning Sheets • Kodak Digital Science Roller Cleaning Pads • Staticide Wipes for Kodak Scanners • A vacuum cleaner and tools 5-2 A-61500 April 2009 Use of new shift shift x x x x x x x x Use only these cleaning tools and materials when performing routine maintenance on your scanner. Procedure Vacuum output tray...
User Guide
Page 43
... "Replacement procedures" later in order to the MSDS for more information. Manually rotate and wipe the separation roller tires with soap and water after performing maintenance procedures. 6. Pull the separation pad holder forward and remove the separation roller. IMPORTANT: The roller cleaning pad contains sodium lauryl ether sulfate and sodium silicate...
... "Replacement procedures" later in order to the MSDS for more information. Manually rotate and wipe the separation roller tires with soap and water after performing maintenance procedures. 6. Pull the separation pad holder forward and remove the separation roller. IMPORTANT: The roller cleaning pad contains sodium lauryl ether sulfate and sodium silicate...
User Guide
Page 48
.... Power on the guides. 26. Carefully vacuum the areas between the lamps. 24. Handle the imaging guides carefully as to not put fingerprints on the scanner. Clean the imaging guides thoroughly with soap and water after performing maintenance procedures. 23. Wash your hands with a Staticide wipe.
.... Power on the guides. 26. Carefully vacuum the areas between the lamps. 24. Handle the imaging guides carefully as to not put fingerprints on the scanner. Clean the imaging guides thoroughly with soap and water after performing maintenance procedures. 23. Wash your hands with a Staticide wipe.
User Guide
Page 61
.... 294 The lower imaging guide is dirty or there may require repair. • Turn the power off to calibrate the scanner again. See 139 Chapter 5, Maintenance. • Clean both printers installed Check document preparation Check imaging guides and lamps Clean lower imaging guide ID# Operator Message 381 The Background Accessory was changed while...
.... 294 The lower imaging guide is dirty or there may require repair. • Turn the power off to calibrate the scanner again. See 139 Chapter 5, Maintenance. • Clean both printers installed Check document preparation Check imaging guides and lamps Clean lower imaging guide ID# Operator Message 381 The Background Accessory was changed while...
User Guide
Page 62
...need to allow a larger value for the document counter. The scanner was unable to find the document edges to calibrate the scanner again. See Chapter 5, Maintenance for more information. A full-width, nondeskewed image has been created. • The document is too dark. • The image ...are correct and that may also be rescanned. See Chapter 5, Maintenance for procedures. 124 The document counter is larger than the maximum configured value. • Reconfigure the scanner to be caused by poor document separation. • Replace the separation roller tires and pre-...
...need to allow a larger value for the document counter. The scanner was unable to find the document edges to calibrate the scanner again. See Chapter 5, Maintenance for more information. A full-width, nondeskewed image has been created. • The document is too dark. • The image ...are correct and that may also be rescanned. See Chapter 5, Maintenance for procedures. 124 The document counter is larger than the maximum configured value. • Reconfigure the scanner to be caused by poor document separation. • Replace the separation roller tires and pre-...
User Guide
Page 63
...your application is set up. • Verify the last document that was scanned correctly. • Place any jammed documents from inside the transport. • Close the pod. Refer...installed properly. Informational message. The lamps were turned off due to inactivity. See Chapter 5, Maintenance, for correct installation procedures. • If the problem persists, call Service. 4 The ...job settings for illegal combinations. This does not indicate that a calibrate is needed . The scanner was attempted before the lamps were warmed up. • Wait until the lamps have been...
...your application is set up. • Verify the last document that was scanned correctly. • Place any jammed documents from inside the transport. • Close the pod. Refer...installed properly. Informational message. The lamps were turned off due to inactivity. See Chapter 5, Maintenance, for correct installation procedures. • If the problem persists, call Service. 4 The ...job settings for illegal combinations. This does not indicate that a calibrate is needed . The scanner was attempted before the lamps were warmed up. • Wait until the lamps have been...
User Guide
Page 64
... in use . • Reload the most recent version of the documents are using the correct calibration target. See Chapter 3, "Calibrating the Scanner". • If the problem persists, call Service. 281 Informational message. The back-up with the scanner. 336 Informational message. See Chapter 5, Maintenance for procedures. • Try to keep up firmware is being...
... in use . • Reload the most recent version of the documents are using the correct calibration target. See Chapter 3, "Calibrating the Scanner". • If the problem persists, call Service. 281 Informational message. The back-up with the scanner. 336 Informational message. See Chapter 5, Maintenance for procedures. • Try to keep up firmware is being...
User Guide
Page 68
... powered on. • Turn the power off to calibrate the scanner again. See Chapter 5, Maintenance for more information. • Check the condition of your feed module and separation roller tires and your documents is too small. See Chapter 3, "Calibrating the scanner". • The calibration target is too small. 81 • Make sure the leading...
... powered on. • Turn the power off to calibrate the scanner again. See Chapter 5, Maintenance for more information. • Check the condition of your feed module and separation roller tires and your documents is too small. See Chapter 3, "Calibrating the scanner". • The calibration target is too small. 81 • Make sure the leading...
User Guide
Page 69
... installed in the imaging guide area. • Clean the imaging guides. The scanner was unable to find the document edges to calibrate the scanner again. See Chapter 5, Maintenance for more information. NOTE:The ink cartridge must be caused by poor document separation. • Replace the separation roller tires and pre-separation pad. This condition may...
... installed in the imaging guide area. • Clean the imaging guides. The scanner was unable to find the document edges to calibrate the scanner again. See Chapter 5, Maintenance for more information. NOTE:The ink cartridge must be caused by poor document separation. • Replace the separation roller tires and pre-separation pad. This condition may...
User Guide
Page 70
...The lamps were turned off due to be different depending on how your application is not installed properly. Remove some documents from inside the transport. • Close the pod. See Chapter 5, Maintenance, for correct installation procedures. • If the problem persists, call Service. 4 The image processing values sent ... the elevator tray and begin scanning. 107 359, 19 108 280 355 46 One or more documents that a calibrate is a general guideline. The scanner was attempted before the lamps were warmed up. • Wait for the message Lamps ready for scanning to inactivity. The ...
...The lamps were turned off due to be different depending on how your application is not installed properly. Remove some documents from inside the transport. • Close the pod. See Chapter 5, Maintenance, for correct installation procedures. • If the problem persists, call Service. 4 The image processing values sent ... the elevator tray and begin scanning. 107 359, 19 108 280 355 46 One or more documents that a calibrate is a general guideline. The scanner was attempted before the lamps were warmed up. • Wait for the message Lamps ready for scanning to inactivity. The ...
User Guide
Page 71
... automatically resume after power-on self-test failed Printer bitmap font in use Rear calibration failed Rear calibration succeeded Refeed document set Requested pages scanned Paused for more information. • Check the condition of your feed module and separation roller...firmware was closed completely. 20 Informational message. See Chapter 5, Maintenance for procedures. • Try to avoid this condition. 91 The expected production version of operational scanner firmware. 26 Informational message. The scanner has completed its self-tests after the capture software application ...
... automatically resume after power-on self-test failed Printer bitmap font in use Rear calibration failed Rear calibration succeeded Refeed document set Requested pages scanned Paused for more information. • Check the condition of your feed module and separation roller...firmware was closed completely. 20 Informational message. See Chapter 5, Maintenance for procedures. • Try to avoid this condition. 91 The expected production version of operational scanner firmware. 26 Informational message. The scanner has completed its self-tests after the capture software application ...
User Guide
Page 75
... wear and replace these parts if necessary. • a very dark document on the bottom of the stack and scan again. See Chapter 5, Maintenance. • the scanner has been calibrated. If unsatisfactory image quality persists, call Service. Problem ...documents that : • the output tray and side guides are adjusted for size, weight, height or batched documents, etc. • the sensors are clean. • the separation roller, feed module, and pre-separation pad are clean and properly installed. • the transport rollers are using the Kodak i600/i700 Series Scanners. Scanner...
... wear and replace these parts if necessary. • a very dark document on the bottom of the stack and scan again. See Chapter 5, Maintenance. • the scanner has been calibrated. If unsatisfactory image quality persists, call Service. Problem ...documents that : • the output tray and side guides are adjusted for size, weight, height or batched documents, etc. • the sensors are clean. • the separation roller, feed module, and pre-separation pad are clean and properly installed. • the transport rollers are using the Kodak i600/i700 Series Scanners. Scanner...
User Guide
Page 76
... located in the correct position for printing. • make sure that the ink cartridge carrier is installed properly. See Chapter 5, Maintenance. See Chapter 5, Maintenance. Roller marks appear on the imaging guides, replace them. If scratches are using a good, clean calibration target and that :...out to provide support for long documents. • the output tray is securely attached. • verify that all documents from the elevator tray and be dirty. Use the calibration target provided with your scanner. Problem Possible Solution Long documents are not feeding or are Make...
... located in the correct position for printing. • make sure that the ink cartridge carrier is installed properly. See Chapter 5, Maintenance. See Chapter 5, Maintenance. Roller marks appear on the imaging guides, replace them. If scratches are using a good, clean calibration target and that :...out to provide support for long documents. • the output tray is securely attached. • verify that all documents from the elevator tray and be dirty. Use the calibration target provided with your scanner. Problem Possible Solution Long documents are not feeding or are Make...