.... • Periodic checks of the operator are required to ensure safe operation. • The model number is to be installed and serviced by texting the photo to receive updates and offers from LiftMaster SM Take a photo of door operation per hour. • DO NOT use with sectional type... doors. Light-Duty Jackshaft Operator for Rolling Doors Model LJ8950W For Light Duty Commercial Use Install On Rolling Doors Only NOT ...
.... • Periodic checks of the operator are required to ensure safe operation. • The model number is to be installed and serviced by texting the photo to receive updates and offers from LiftMaster SM Take a photo of door operation per hour. • DO NOT use with sectional type... doors. Light-Duty Jackshaft Operator for Rolling Doors Model LJ8950W For Light Duty Commercial Use Install On Rolling Doors Only NOT ...
LJ8950W Manual
Page 4
Battery Backup (Model 485LM): Provides backup power to install the safety reversing sensor. Introduction Carton Inventory Your door operator is missing, carefully check the packing material. 2-Conductor Bell ... hardware not provided. 90˚ connector for cable conduit or flex cable adapter: Required for Release Handle (1) Additional Items You May Need Extension brackets (Model 041A5281-1) or wood blocks: Depending upon building construction, extension brackets or wood blocks may be needed to the door operator. 4
Battery Backup (Model 485LM): Provides backup power to install the safety reversing sensor. Introduction Carton Inventory Your door operator is missing, carefully check the packing material. 2-Conductor Bell ... hardware not provided. 90˚ connector for cable conduit or flex cable adapter: Required for Release Handle (1) Additional Items You May Need Extension brackets (Model 041A5281-1) or wood blocks: Depending upon building construction, extension brackets or wood blocks may be needed to the door operator. 4
LJ8950W Manual
Page 5
... on the right or left side of the operator depending on each side of the drive sprocket with the door sprocket. 1. An optional mounting bracket Model 3950MB is available for purchase, see Accessories page 30. 1. Mounting Brackets 5 Insert bolts into the motor shaft. 2. The drive sprocket can be mounted in one...
... on the right or left side of the operator depending on each side of the drive sprocket with the door sprocket. 1. An optional mounting bracket Model 3950MB is available for purchase, see Accessories page 30. 1. Mounting Brackets 5 Insert bolts into the motor shaft. 2. The drive sprocket can be mounted in one...
LJ8950W Manual
Page 7
... door shaft must extend past the drum bracket a minimum of 1.5" (3.8 cm) (2.5" [6.3 cm] recommended) for standard wall mounting or outside mounting using the optional mounting bracket Model 3950MB. Clearance Outside Mounting 3.75" (9.5 cm) Min. MINIMUM SIDE CLEARANCE A minimum of 11" (27.9 cm) clearance on the outside of the door opening is required....9 cm) Min. Installation Live Shaft Door Requirements For live shaft door installations the door sprocket is required for inside mounting using the optional mounting bracket Model 3950MB.
... door shaft must extend past the drum bracket a minimum of 1.5" (3.8 cm) (2.5" [6.3 cm] recommended) for standard wall mounting or outside mounting using the optional mounting bracket Model 3950MB. Clearance Outside Mounting 3.75" (9.5 cm) Min. MINIMUM SIDE CLEARANCE A minimum of 11" (27.9 cm) clearance on the outside of the door opening is required....9 cm) Min. Installation Live Shaft Door Requirements For live shaft door installations the door sprocket is required for inside mounting using the optional mounting bracket Model 3950MB.
LJ8950W Manual
Page 10
...; Standard wall mount using the brackets included with the door operator. • Outside bracket mount using the optional mounting bracket Model 3950MB. • Inside bracket mount using the optional mounting bracket Model 3950MB. Installation 2 Mount the Door Operator MOUNTING OPTIONS There are under EXTREME tension. • ALWAYS call an authorized service technician...
...; Standard wall mount using the brackets included with the door operator. • Outside bracket mount using the optional mounting bracket Model 3950MB. • Inside bracket mount using the optional mounting bracket Model 3950MB. Installation 2 Mount the Door Operator MOUNTING OPTIONS There are under EXTREME tension. • ALWAYS call an authorized service technician...
LJ8950W Manual
Page 11
Connect the ends of the chain using a 5/32" Allen wrench. If the operator is mounted below 8 ft. (2.5 m), chain guard model 3950CGJ must be mounted in the alignment of three positions to protect against possible injury, see accessories page 30. Tighten the drive sprocket bolts using ...
Connect the ends of the chain using a 5/32" Allen wrench. If the operator is mounted below 8 ft. (2.5 m), chain guard model 3950CGJ must be mounted in the alignment of three positions to protect against possible injury, see accessories page 30. Tighten the drive sprocket bolts using ...
LJ8950W Manual
Page 16
LiftMaster Light Curtain (Model LC-36A) is an ancillary entrapment protection device designed with 8 optical sensors that no part of dangerous machinery or in explosive atmospheres or radioactive environments. The minimum installation width is 3 ft. (.91 m) and the maximum width is for a typical installation, refer to the complete instructions included with LiftMaster... Light Curtain may NOT be installed ONLY by authorized and fully trained personnel. • LiftMaster Monitored Entrapment Protection devices are aligned. Secure the bottom mounting bracket to the mounting surface....
LiftMaster Light Curtain (Model LC-36A) is an ancillary entrapment protection device designed with 8 optical sensors that no part of dangerous machinery or in explosive atmospheres or radioactive environments. The minimum installation width is 3 ft. (.91 m) and the maximum width is for a typical installation, refer to the complete instructions included with LiftMaster... Light Curtain may NOT be installed ONLY by authorized and fully trained personnel. • LiftMaster Monitored Entrapment Protection devices are aligned. Secure the bottom mounting bracket to the mounting surface....
LJ8950W Manual
Page 25
If your vehicle is equipped with the accessory or visit LiftMaster.com. ERASE A myQ ACCOUNT Go to myLiftMaster.com to delete your vehicle. LEARN Button Black ...are now erased. Programming Remote Control (Not Provided) Up to 40 Security+ 2.0 remote controls can be programmed to use . Older LiftMaster remote controls are now erased. To program additional accessories refer to use . All remote control and keyless entry codes are NOT compatible,... Wi-Fi NETWORK FROM THE DOOR OPERATOR Press and hold the LEARN button on the make, model, and year of your myQ account.
If your vehicle is equipped with the accessory or visit LiftMaster.com. ERASE A myQ ACCOUNT Go to myLiftMaster.com to delete your vehicle. LEARN Button Black ...are now erased. Programming Remote Control (Not Provided) Up to 40 Security+ 2.0 remote controls can be programmed to use . Older LiftMaster remote controls are now erased. To program additional accessories refer to use . All remote control and keyless entry codes are NOT compatible,... Wi-Fi NETWORK FROM THE DOOR OPERATOR Press and hold the LEARN button on the make, model, and year of your myQ account.
LJ8950W Manual
Page 30
... Light: Wireless light that you have access to your door operator while calling. G485LM Battery Backup: Provides backup power to : LiftMaster 6050 S. STANDARD ACCESSORIES G891LM Single Button Remote Control: Includes visor clip. Country Club Rd. App Store is a trad3e0mark of the door...For installation and service information call: 1-800-528-9131 Or visit us online at: LiftMaster.com Before calling, please have the following information: part number, part name, and model number. 114A5003C © 2017, LiftMaster All Rights Reserved Wi-Fi® is exposed lower than 8 ft. (2.5 m). ...
... Light: Wireless light that you have access to your door operator while calling. G485LM Battery Backup: Provides backup power to : LiftMaster 6050 S. STANDARD ACCESSORIES G891LM Single Button Remote Control: Includes visor clip. Country Club Rd. App Store is a trad3e0mark of the door...For installation and service information call: 1-800-528-9131 Or visit us online at: LiftMaster.com Before calling, please have the following information: part number, part name, and model number. 114A5003C © 2017, LiftMaster All Rights Reserved Wi-Fi® is exposed lower than 8 ft. (2.5 m). ...
Instructions - English French Spanish
Page 1
... over motor sprocket, push clevis pin into place, install C-clip. Ensure the wire harnesses are known to the quick connect terminals (C). 15. 12V Replacement Motor Model 041D1624-2 1. Reconnect the wires to the State of replacement receiver logic board during installation. Open the front panel (A). Verify that the tabs in the cover...
... over motor sprocket, push clevis pin into place, install C-clip. Ensure the wire harnesses are known to the quick connect terminals (C). 15. 12V Replacement Motor Model 041D1624-2 1. Reconnect the wires to the State of replacement receiver logic board during installation. Open the front panel (A). Verify that the tabs in the cover...
Light-Duty Operator Brochure
Page 2
... LIGHTING MyQ® Remote LED Light 827LM Can be scheduled to keep your workspace. Requires purchase of remotes for commercial applications requiring a large number of Model 485LM. door. With our first Wi-Fi® commercial door operators, you have to 20 open and close doors from anywhere and will always know...
... LIGHTING MyQ® Remote LED Light 827LM Can be scheduled to keep your workspace. Requires purchase of remotes for commercial applications requiring a large number of Model 485LM. door. With our first Wi-Fi® commercial door operators, you have to 20 open and close doors from anywhere and will always know...
myQ Business Product Brochure - English
Page 7
... multiple team members or groups to send alerts anytime our doors were left open for first-call resolution and reduced downtime, including: • Door & Operator Model • System Cycle Usage • Installed Accessories and More SET ALERTS. When we didn't know.
... multiple team members or groups to send alerts anytime our doors were left open for first-call resolution and reduced downtime, including: • Door & Operator Model • System Cycle Usage • Installed Accessories and More SET ALERTS. When we didn't know.