P401 : user's manual - Page 3
...may cause harmful interference to part 15 of Product:
Display Monitor
Equipment Classification: Class B Peripheral
Model:
MultiSync P401 (L408TM) MultiSync P461 (L468TN) MultiSync P521 (L528N7) MultiSync P551 (L559NL)
We hereby declare that to which can radiate radio frequency energy, and, if not installed and used in accordance with the instructions, may not cause harmful interference...
P401 : user's manual - Page 37
...contact
your nearest authorized NEC DISPLAY SOLUTIONS service facility.
•... display card or system manual to change graphics mode...make sure that a supported mode has been selected...set at the monitor's remote sensor.
• Check the Remote Control Mode status.
• The remote control system may appear, depending on the specific...image was displayed. Troubleshooting
English
No picture ...
P401 : RS232 codes for X461UN, X461HB, X431BT, P401, P461, P521, P551, P701, S401, S461 and S521 - Page 5
... this "command message" is used for some non-slider controls and some special operations, such as follows,
STX
OP code OP code page
Set Value
ETX
Hi Lo Hi Lo MSB
LSB
Refer to section 5.4 "Set parameter reply" for more details.
5 Command "Command message" format depends on each command. Message format of the...
P401 : RS232 codes for X461UN, X461HB, X431BT, P401, P461, P521, P551, P701, S401, S461 and S521 - Page 12
... is 50(0032h) . Delimiter CR (0Dh): End of packet
Step 2. The monitor replies with current Brightness setting and capability to support this byte is set to change the Brightness setting
Header SOH-'0'-Monitor ID-'0'-'E'-'0'-'A'
Message STX-'0'-'0'-'1'-'0'-'0'-'0'-'5'-'0'-ETX
Check code BCC
Header SOH (01h): Start Of Header '0' (30h): Reserved Monitor ID: Specify the Monitor ID of...
P401 : RS232 codes for X461UN, X461HB, X431BT, P401, P461, P521, P551, P701, S401, S461 and S521 - Page 13
... length is 18 bytes. ETX (03h): End of Message
Check code
BCC: Block Check Code Refer to the section 4.5 "Check code" for a BCC calculation. No error. '0'-'0' (30h, 30h): Operation code page number is 0. '1'-'0' (31h, 30h): Operation code is 10h (in the page 0). '0'-'0' (30h, 30h): This operation is "Set parameter" type. '0'-'0'-'6'-'4' (30h, 30h, 36h, 34h): Brightness max value...
P401 : RS232 codes for X461UN, X461HB, X431BT, P401, P461, P521, P551, P701, S401, S461 and S521 - Page 14
....) When this byte is 18 bytes. No error. '0'-'2' (30h, 32h): Operation code page number is 2. '7'-'8' (37h, 38h): Operation code is 78h (in the page 2). '0'-'0' (30h, 30h): This operation is "Set parameter" type. '0'-'0'-'0'-'3' (30h, 30h, 30h, 33h): Number of Message '0'-'2' (30h, 32h): Operation code page number is 2. '7'-'8' (37h, 38h): Operation code is the controller. Message STX (02h...
P401 : RS232 codes for X461UN, X461HB, X431BT, P401, P461, P521, P551, P701, S401, S461 and S521 - Page 15
..., 46h): Maximum value. '0'-'0'-'3'-'2' (30h, 30h, 33h, 32h): The temperature is 79h (in the page 2).
Ex.) When this byte is set to get a value.
No error. '0'-'2' (30h, 32h): Operation code page number is 2. '7'-'9' (37h, 39h): Operation code is 25 degrees Celsius. Monitor ID: Indicate a replying Monitor ID.
ETX (03h): End of Header
'0' (30h): Reserved
'0' (30h...
P401 : RS232 codes for X461UN, X461HB, X431BT, P401, P461, P521, P551, P701, S401, S461 and S521 - Page 18
... not set 20h: Read data from top of Message
Check code BCC: Block Check Code Refer to get data.
Header SOH-'0'-'0'-Monitor ID-'B'-N-N
Message STX-'C'-'1'-'0'-'B'Data(0)-Data(1)---Data(N)-ETX
Check code BCC
Delimiter CR
Header SOH (01h): Start of Message
Check code BCC: Block Check Code Refer to store user's asset data of packet
8. No error. 'C'-'2','0'-'3'-'D'-'6' (43h...
P401 : RS232 codes for X461UN, X461HB, X431BT, P401, P461, P521, P551, P701, S401, S461 and S521 - Page 20
....
ETX (03h): End of Message
Check code BCC: Block Check Code Refer to 'A', the replying Monitor ID is '1'. 'B' (42h): Message type is "Command". '0'-'6'(30h, 36h): Message length
Message STX (02h): Start of Message 'C'-'2'-'1'-'1' (43h, 32h, 31h, 31h): Date & time read the setting of Message
(20/50)
No error. 'C'-'0'-'0'-'E' (43h, 30h, 30h, 45h): Asset Data...
P401 : RS232 codes for X461UN, X461HB, X431BT, P401, P461, P521, P551, P701, S401, S461 and S521 - Page 40
... 2nd '0'-'0'(30h, 30h): "0" | '0'-'9'(30h, 39h): "9"
P3: Security Pass code 3rd '0'-'0'(30h, 30h): "0" | '0'-'9'(30h, 39h): "9"
P4: Security Pass code 4th '0'-'0'(30h, 30h): "0" | '0'-'9'(30h, 39h): "9"
ETX (03h): End of which you want to change a setting.
Header
Message
Check
code
SOH-'0'-MonitorID-'0'-'A'-'1'-'0' STX-'C'-'2'-'1'-'D'-EN-P1-P2-P3-P4-ETX BCC
Delimiter CR
Header SOH (01h...
P401 : RS232 codes for X461UN, X461HB, X431BT, P401, P461, P521, P551, P701, S401, S461 and S521 - Page 49
...: ISF-Night: Each needs an adjustment by side (Full) 0: No mean 1: VGA 2: RGB/HV 3: DVI 4: HDMI (Set only) 5: Video1 6: Video2 7: S-Video 10: TV 12: DVD/HD1 13: Option 14: DVD/HD2 15: Display Port ... supported option TV tuner. Refer to
the
monitor
instruction
manual.
Read only
Read only
Read only
sensor
Carbon Temperature
footprint
(49/50) Item Picture Mode
OP code page 02h
OP code ...
P Series Specification Brochure - Page 2
... the environmental conditions noted in the specifications and user's manual **available on select models
Department of Energy, helping you to... support video wall configurations
Select P Series displays' thin-bezel design and enhanced video wall capabilities allow users to control settings...all others in the RS-232 daisy chain, reducing setup time and saving money
• Individual and Group ID...
P Series Specification Brochure - Page 3
... (NET-SBC-01/02/03): This option provides for a seamless internal PC solution that simplifies installation and reduces maintenance.
• DVI daisychain (SB-L008WU)**: Loop in the specifications and user's manual **available on select models
S-Video In
Speaker Out These include:
• RS-232 enables multi-display control and daisy chain, allowing...
P Series Specification Brochure - Page 4
...-120V 1.5 A@220-240V 4.9 A@100-120V 2.0 A@220-240V 5.3A@100-120V 2.2A@220-240V 9.2 A@100-120V 3.7 A@220-240V
145W
155W
290W
280W
600W Specifications for P402/P462/P521/P551/P701
MODEL LCD MODULE Viewable Size (Diagonal) Panel Technology Native Resolution Pixel Pitch Brightness (Typical/Maximum) Contrast Ratio (Typical) Active Screen Area (W x H)
P402
P462...
MPD-DTi Specification Brochure - Page 2
... a simple setup scenario. Unicast
Multicast
NEC Displays Supported
Source
router
...service, points of viewing as well as a one-to change. 1/12 ver. 3.