Owners Manual for TGB516NX - Page 1
Read instructions before using the machine
www.numatic.co.uk 1 TTB 1840 36V
SCRUBBER DRYER
Original Instructions
Caution!
Owners Manual for TGB516NX - Page 2
... Floor-tool Blades Page 10
Lifting the Machine Page 11
Specifications
Page 12
Trouble Shooting
Page 12
About the Machine Page 13
Rating Label / PPE / Recycling
Page 13
Information for Scrubber Dryer Page 14
Twintec Maintenance Page 15
Spare Parts
Page 15
Recommended Spare Parts Page 15
Schematic Diagram
Page 15
EU Declaration Document...
Owners Manual for TGB516NX - Page 5
... / pad in place (Fig.4).
AFTER THE REMOVAL OF ALL THE PACKAGING, CAREFULLY OPEN AND CHECK THE CONTENTS.
!
1
2
TTB 1840 36V CONTENTS
● Owner Manual ● Battery & Charger Manual
● Battery Charger & Lead ● Battery ● Scrub Brush ● Squeegee Assembly
Using the handle position lever, (Fig.1)
Move the handle into the battery...
Owners Manual for TGB516NX - Page 6
...the clean water tap. Safety gloves are recommended for quick fitting, allowing easy squeegee blade replacement and a safety knock-off feature if the floor-tool gets snagged, whilst in place... in transit.
ALWAYS ENSURE THAT THE MACHINE IS SWITCHED OFF BEFORE MAKING ANY ADJUSTMENTS
!
Machine Set-up Guide
! Slide the brush / pad under the brush deck.
Turn on the brush. Fit the...
Owners Manual for TGB516NX - Page 7
Machine Set-up Guide
Filling the Clean Water Tank
The TTB 1840 is the On / Off water tap (Fig.1). Fill Level Indicator
A...the fill indicator (Fig.3). NOTE: Great care must be cleaned in a single fill. If using a hose or a suitable container (Fig.2). Set the tap to enter the clean water tank during the filling process.
T 01460 68600
6 Fill using a suitable container, ensure it is ...
Owners Manual for TGB516NX - Page 8
...a number of times then pause. F
1) Battery Low
2) Battery over temperature
3) Battery communications error
4) Control board over temperature 5) System power exceeded
6) Vacuum overload
7) Brush overload
8) Control ... press button (D).
The lights will continue for use when the machine is pulled. Setting the Cleaning Controls
On / Off
A B
Trigger
Trigger
To check the battery level...
Owners Manual for TGB516NX - Page 9
...HANDLING CHEMICALS Always ensure that exceed (2%),when full. Machine In Use
To operate, set water flow rate tap, lower the floor-tool, press the vacuum / water switches... is then retrieved by 10cm to ensure an even clean.
IMPORTANT Do not operate machine unless the Operator Manual has been read
and fully understood.
!
If streaking occurs wipe floor-tool blades clean. On heavily soiled...
Owners Manual for TGB516NX - Page 10
... Tank
After use, empty waste-water tank using clean water.
1 2
3 4
5
6
Remove the filter and basket clipped into the separator and flush with clean
water. (fig.A). Replace the filter by hand. (fig.B).
Owners Manual for TGB516NX - Page 11
... Squeegee blades using the two central knobs to the moulded location lugs. Refit the floor-tool using (903531) replacement blade set (Fig.3), fitting the blades on to the floor-tool.
Floor-tool Overview
1.
Retaining knobs x 4
2. Floor-tool main body
4
3
2 1
T 01460 68600
10 ALWAYS ENSURE THAT THE ...
Owners Manual for TGB516NX - Page 13
...vary dependent on ambient temperature.
*Charge Time
*80%=60 Min *100%=120 Min
Trouble Shooting
PROBLEM
Machine will not operate Vacuum not operating Poor water pick-up
No brush / ...setting Tank filter blocked
Too much load on the brush system
SOLUTION
Insert battery (page 4) Recharge battery (See battery & charger instructions) Replace battery (page 4) Turn on vacuum (page 7) Contact service...
Owners Manual for TGB516NX - Page 15
... brushes provided with the correct Numatic approved replacement parts. • Ensure that routine and preventative maintenance is carried out periodically in order to be disconnected by any inexperienced repairs. The use brushes or pads which are used , read the manufacturer's instructions. Only use of the machine for the specific task being performed. It is essential...
Owners Manual for TGB516NX - Page 16
...
Spare Parts
Part No. 903531 903532 303985 903544 237232 237411 213054 213055 303997 208471 903325 905628
SPARES & ACCESSORIES SERILOR REPLACEMENT BLADE SET SERILOR ...COMPLETE SQUEEGEE ASSEMBLY FILLER CAP ASSEMBLY FILLER CAP LID SEPARATOR FILTER GRIT BASKET SUCTION HOSE VAC HOSE DUMP HOSE ASSEMBLY CONSTANT TENSION CLIP(DUMP HOSE) 32MM HOSE CAP(RED) 1840 SERVICE...
Owners Manual for TGB516NX - Page 20
... www.numatic.pt
Numatic International SLU.
Sihlbruggstrasse 3A, 6340 Baar. Chard, Somerset TA20 2GB ENGLAND Tel.: 01460 68600 www.numatic.co.uk
Numatic International GmbH. Specification subject to change without prior notice
www.numatic.co.uk © Numatic International Limited
912765 06/21 (A04)