User's Manual
Page 59
... lower than or equal to the Replacing the lamp section. 4 Make sure you are using . choose the resolution mode you will also need under the "Models" box. 8. Select the Change button under the SP box; Select the Settings tab. 3. Verify that your display resolution setting is still not projecting the whole...
... lower than or equal to the Replacing the lamp section. 4 Make sure you are using . choose the resolution mode you will also need under the "Models" box. 8. Select the Change button under the SP box; Select the Settings tab. 3. Verify that your display resolution setting is still not projecting the whole...
User's Manual
Page 73
... o v For wide 1024x768 75 o screen 1024x768 85 o resolution (WXGA), the 1280x720 60 o compatibility 1280x720 75 o support is 1280x720 85 o dependent on Notebook/PC 1280x768 60 o models. 1280x768 75 o 1280x768 85 o 1280x800 60 o 1280x1024 60 - 1280x1024 75 - 1680x1050 60 o 1920x1200 60 o Macbook Pro (Intel) Analog o o o o o o o o o o o o o o o o o o o Power Mac G5 Analog o o o o o o o o o o o o - Appendices Signal Resolution...
... o v For wide 1024x768 75 o screen 1024x768 85 o resolution (WXGA), the 1280x720 60 o compatibility 1280x720 75 o support is 1280x720 85 o dependent on Notebook/PC 1280x768 60 o models. 1280x768 75 o 1280x768 85 o 1280x800 60 o 1280x1024 60 - 1280x1024 75 - 1680x1050 60 o 1920x1200 60 o Macbook Pro (Intel) Analog o o o o o o o o o o o o o o o o o o o Power Mac G5 Analog o o o o o o o o o o o o - Appendices Signal Resolution...
User's Manual
Page 75
Lead Code Projector ID ~ Fix code One Digit X X Set in OSD 00~99 Two Digit 00 is dependent on the model purchased. Appendices RS232 Protocol Function List RS232 Commands Baud Rate Data Bits Parity Check Stop Bits Flow Control UART16550 FIFO 9600 8 None 1 None ...Disable v Due to the difference application for universal use Command ID X X X Defined by Optoma 2 or 3 Digit See the Follow content space variable n carriage return CR One Digit Per item Definition Fix code One Digit Keypad Command Power Power On...
Lead Code Projector ID ~ Fix code One Digit X X Set in OSD 00~99 Two Digit 00 is dependent on the model purchased. Appendices RS232 Protocol Function List RS232 Commands Baud Rate Data Bits Parity Check Stop Bits Flow Control UART16550 FIFO 9600 8 None 1 None ...Disable v Due to the difference application for universal use Command ID X X X Defined by Optoma 2 or 3 Digit See the Follow content space variable n carriage return CR One Digit Per item Definition Fix code One Digit Keypad Command Power Power On...
User's Manual
Page 78
...Device discovery is running on a dedicated application port) English 78 On recognition of the poll, the Optoma projector will respond with a beacon string (in ASCII followed by a carriage return ('\r', 0x0D) Revision ... Captioning ʳ ʳ n= -5 - +5 ʳ n= -5 - +5 ʳ n= -5 - +5 Hour/Day/Month nnnnnn ʳ Enable/Disable n=1/n=2 &0 ʳ n=00-99 On/Off n=1/n=2 &0 ʳ n=0-10 Optoma/User n=1/n=2 ʳ n=1 On/Off n=1/n=2 &0 RS232 n=1 Network n=2 ASCII ~XX74 n ~XX75 n ~XX76 n ~XX77 n ʳ ~XX78 n ~XX79 n ~XX80 n ~XX81 n ~XX82 n ~XX83 n ~XX88 n...
...Device discovery is running on a dedicated application port) English 78 On recognition of the poll, the Optoma projector will respond with a beacon string (in ASCII followed by a carriage return ('\r', 0x0D) Revision ... Captioning ʳ ʳ n= -5 - +5 ʳ n= -5 - +5 ʳ n= -5 - +5 Hour/Day/Month nnnnnn ʳ Enable/Disable n=1/n=2 &0 ʳ n=00-99 On/Off n=1/n=2 &0 ʳ n=0-10 Optoma/User n=1/n=2 ʳ n=1 On/Off n=1/n=2 &0 RS232 n=1 Network n=2 ASCII ~XX74 n ~XX75 n ~XX76 n ~XX77 n ʳ ~XX78 n ~XX79 n ~XX80 n ~XX81 n ~XX82 n ~XX83 n ~XX88 n...
User's Manual
Page 79
F Input Source Display Function ACCII Display Fail Input Source n=1 ~XX121 n Oka F Note: The command ~XX121 n MUST work when projector is in standby mode Model Name Function ASCII Display Depends Fail Model Name n=1 ~XX151 n Oka a=1/2/ 1=EX785, 2=EW775 F RS232 Version No Function ASCII Display Depends Fail RS232 Version No n=1 ~XX152 n Oka a=?? Appendices Information Format: INFOa...
F Input Source Display Function ACCII Display Fail Input Source n=1 ~XX121 n Oka F Note: The command ~XX121 n MUST work when projector is in standby mode Model Name Function ASCII Display Depends Fail Model Name n=1 ~XX151 n Oka a=1/2/ 1=EX785, 2=EW775 F RS232 Version No Function ASCII Display Depends Fail RS232 Version No n=1 ~XX152 n Oka a=?? Appendices Information Format: INFOa...
Protocol Function
Page 2
... Bits Parity Check Stop Bits Flow Control UART16550 FIFO 9600 8 None 1 None Disable Due to the difference application for universal use Command ID X X X Defined by Optoma 2 or 3 Digit See the Follow content space variable n carriage return CR One Digit Per item Definition Fix code One Digit Keypad Command Power Power On... n ~XX23 n Pass Fail P F P F P F P F 75 English Lead Code Projector ID ~ Fix code One Digit X X Set in OSD 00~99 Two Digit 00 is dependent on the model purchased. Function is for each...
... Bits Parity Check Stop Bits Flow Control UART16550 FIFO 9600 8 None 1 None Disable Due to the difference application for universal use Command ID X X X Defined by Optoma 2 or 3 Digit See the Follow content space variable n carriage return CR One Digit Per item Definition Fix code One Digit Keypad Command Power Power On... n ~XX23 n Pass Fail P F P F P F P F 75 English Lead Code Projector ID ~ Fix code One Digit X X Set in OSD 00~99 Two Digit 00 is dependent on the model purchased. Function is for each...
Protocol Function
Page 5
...in ASCII) identifying your device. On recognition of the poll, the Optoma projector will respond with a beacon string (in this case Optoma). Device discovery is "AMX" in RS232 protocol In basic terms, AMX... Closed Captioning ʳ ʳ n= -5 - +5 ʳ n= -5 - +5 ʳ n= -5 - +5 Hour/Day/Month nnnnnn ʳ Enable/Disable n=1/n=2 &0 ʳ n=00-99 On/Off n=1/n=2 &0 ʳ n=0-10 Optoma/User n=1/n=2 ʳ n=1 On/Off n=1/n=2 &0 RS232 n=1 Network n=2 ASCII ~XX74 n ~XX75 n ~XX76 n ~XX77 n ʳ ~XX78 n ~XX79 n ~XX80 n ~XX81 n ~XX82 n ~XX83 n ~XX88 n ~XX86...
...in ASCII) identifying your device. On recognition of the poll, the Optoma projector will respond with a beacon string (in this case Optoma). Device discovery is "AMX" in RS232 protocol In basic terms, AMX... Closed Captioning ʳ ʳ n= -5 - +5 ʳ n= -5 - +5 ʳ n= -5 - +5 Hour/Day/Month nnnnnn ʳ Enable/Disable n=1/n=2 &0 ʳ n=00-99 On/Off n=1/n=2 &0 ʳ n=0-10 Optoma/User n=1/n=2 ʳ n=1 On/Off n=1/n=2 &0 RS232 n=1 Network n=2 ASCII ~XX74 n ~XX75 n ~XX76 n ~XX77 n ʳ ~XX78 n ~XX79 n ~XX80 n ~XX81 n ~XX82 n ~XX83 n ~XX88 n ~XX86...
Protocol Function
Page 6
... 79 English F Input Source Display Function ACCII Display Fail Input Source n=1 ~XX121 n Oka F Note: The command ~XX121 n MUST work when projector is in standby mode Model Name Function ASCII Display Depends Fail Model Name n=1 ~XX151 n Oka a=1/2/ 1=EX785, 2=EW775 F RS232 Version No Function ASCII Display Depends Fail RS232 Version No n=1 ~XX152 n Oka a=??
... 79 English F Input Source Display Function ACCII Display Fail Input Source n=1 ~XX121 n Oka F Note: The command ~XX121 n MUST work when projector is in standby mode Model Name Function ASCII Display Depends Fail Model Name n=1 ~XX151 n Oka a=1/2/ 1=EX785, 2=EW775 F RS232 Version No Function ASCII Display Depends Fail RS232 Version No n=1 ~XX152 n Oka a=??