CR5000 Measurement and Control Module
Page 3
......1-4 1.5 Direct Battery Connection to the CR5000 Wiring Panel 1-4 1.6 Vehicle Power Supply Connections 1-4 1.7 CR5000 Grounding ...1-6 1.8 Powering Sensors and Peripherals 1-9 1.9 Controlling Power to Sensors and Peripherals 1-10 1.10 Maintenance ...1-12 2. PHYSICAL DESCRIPTION PAGE OV1.1 OV1.2 OV1.3 Measurement Inputs ...OV-1 Communication and Data Storage OV-4 Power Supply and AC Adapter OV-5 OV2. SPECIFICATIONS...OV-20 1. PC9000 APPLICATION SOFTWARE OV3.1 OV3.2 OV3.3 Hardware and Software Requirements OV-6 PC9000 Installation...OV-6 PC9000 Software Overview...
......1-4 1.5 Direct Battery Connection to the CR5000 Wiring Panel 1-4 1.6 Vehicle Power Supply Connections 1-4 1.7 CR5000 Grounding ...1-6 1.8 Powering Sensors and Peripherals 1-9 1.9 Controlling Power to Sensors and Peripherals 1-10 1.10 Maintenance ...1-12 2. PHYSICAL DESCRIPTION PAGE OV1.1 OV1.2 OV1.3 Measurement Inputs ...OV-1 Communication and Data Storage OV-4 Power Supply and AC Adapter OV-5 OV2. SPECIFICATIONS...OV-20 1. PC9000 APPLICATION SOFTWARE OV3.1 OV3.2 OV3.3 Hardware and Software Requirements OV-6 PC9000 Installation...OV-6 PC9000 Software Overview...
CR5000 Measurement and Control Module
Page 5
...) VX1 VX2 VX3 VX4 CAO1 CAO2 IX1 IX2 IX3 IX4 IXR P1 P1 C1 C2 C3 C4 G C5 C6 C7 C8 G >2.0V G The CR5000 includes CPU, keyboard display, power supply, and analog and digital inputs and outputs. The on-board, BASIC-like programming language includes data processing and analysis routines. CR5000 Overview The CR5000 provides precision measurement capabilities in a rugged, battery-operated package.
...) VX1 VX2 VX3 VX4 CAO1 CAO2 IX1 IX2 IX3 IX4 IXR P1 P1 C1 C2 C3 C4 G C5 C6 C7 C8 G >2.0V G The CR5000 includes CPU, keyboard display, power supply, and analog and digital inputs and outputs. The on-board, BASIC-like programming language includes data processing and analysis routines. CR5000 Overview The CR5000 provides precision measurement capabilities in a rugged, battery-operated package.
CR5000 Measurement and Control Module
Page 9
... Counters Reads Control Ports (GetPort) Sets control ports (SetPort) OV-5 OV2.2 Measurements, Processing, Data Storage The CR5000 divides a program into memory. Memory and Programming Concepts OV2.1 Memory The CR5000 has 2MB SRAM and 1MB Flash EEPROM. The measurement task stores raw Analog to the Power In terminal on a rigidly timed sequence. The low profile base requires an external DC power source connected to Digital Converter (ADC) data directly into...
... Counters Reads Control Ports (GetPort) Sets control ports (SetPort) OV-5 OV2.2 Measurements, Processing, Data Storage The CR5000 divides a program into memory. Memory and Programming Concepts OV2.1 Memory The CR5000 has 2MB SRAM and 1MB Flash EEPROM. The measurement task stores raw Analog to the Power In terminal on a rigidly timed sequence. The low profile base requires an external DC power source connected to Digital Converter (ADC) data directly into...
CR5000 Measurement and Control Module
Page 12
.... Get/Set Variable . . . Printer Setup . . . Exit PC9000 Menu-driven Program Generation. Select Parallel Linked Station . . . Logger Clock . . . Display Data Graph 2 . . . Realtime Display & Graphing CR9000 Program Generator CR5000 Program Generator CR9000 Program Editor . . . CR5000 Program Editor . . . Print . . . DOS Shell . . . Download . . . Diagnostics PC to the operator. Graphing requires no special processing of Program View/Edit Wiring Diagram & DataTable Information (Created by Program Generator) View Data Collected from CR5000...
.... Get/Set Variable . . . Printer Setup . . . Exit PC9000 Menu-driven Program Generation. Select Parallel Linked Station . . . Logger Clock . . . Display Data Graph 2 . . . Realtime Display & Graphing CR9000 Program Generator CR5000 Program Generator CR9000 Program Editor . . . CR5000 Program Editor . . . Print . . . DOS Shell . . . Download . . . Diagnostics PC to the operator. Graphing requires no special processing of Program View/Edit Wiring Diagram & DataTable Information (Created by Program Generator) View Data Collected from CR5000...
CR5000 Measurement and Control Module
Page 13
... calibration of menus to five displays simultaneously. Work Area Setup . . . PC9000 Editing, Help, and User Preferences OV3.3.1 File OV3.3.2 Edit Program Generator Guides the user through a series of sensors OV-9 Tile Vertical . . . Search PC9000 Help . . . OV3-2. Provides context-sensitive help for Active Windows. About PC9000 . . . Software Versions . . . Editing Options for Active Windows Change fonts and/or Colors for the CR5000's BASIC-like language. Fonts . . . Defaults . . . Arrange Icons . . . Cascade . . . List...
... calibration of menus to five displays simultaneously. Work Area Setup . . . PC9000 Editing, Help, and User Preferences OV3.3.1 File OV3.3.2 Edit Program Generator Guides the user through a series of sensors OV-9 Tile Vertical . . . Search PC9000 Help . . . OV3-2. Provides context-sensitive help for Active Windows. About PC9000 . . . Software Versions . . . Editing Options for Active Windows Change fonts and/or Colors for the CR5000's BASIC-like language. Fonts . . . Defaults . . . Arrange Icons . . . Cascade . . . List...
CR5000 Measurement and Control Module
Page 15
Keyboard Display Power Up Screen CAMPBELL SCIENTIFIC CR5000 Datalogger 06/18/2000, 18:24:35 CPU: TRIG.CR5 Running. OV4. Press any key for Main Menu (except < >) Data Run/Stop Program File Status Configure, Settings CR5000 Overview Adjust contrast with < > < lighter darker > Real Time Tables Real Time Custom Final Storage Data Reset Data Tables Graph Setup New Edit Copy Delete Run Options Directory Format ROM Version : OS Version : OS Date : OS...
Keyboard Display Power Up Screen CAMPBELL SCIENTIFIC CR5000 Datalogger 06/18/2000, 18:24:35 CPU: TRIG.CR5 Running. OV4. Press any key for Main Menu (except < >) Data Run/Stop Program File Status Configure, Settings CR5000 Overview Adjust contrast with < > < lighter darker > Real Time Tables Real Time Custom Final Storage Data Reset Data Tables Graph Setup New Edit Copy Delete Run Options Directory Format ROM Version : OS Version : OS Date : OS...
CR5000 Measurement and Control Module
Page 24
... filtering on all inputs and outputs. DISPLAY: 8-line-by measuring the duration of a specified number of Reading + Offset) -40° to 16 Vdc TYPICAL CURRENT DRAIN: 400 µA software power off; 1.5 mA sleep mode; 4.5 mA at 1 Hz (200 mA at the user's own expense. SERIAL INTERFACES: Optically isolated RS-232 9-pin interface for data and operating system use with input reversal; CSI/O 9-pin interface for...
... filtering on all inputs and outputs. DISPLAY: 8-line-by measuring the duration of a specified number of Reading + Offset) -40° to 16 Vdc TYPICAL CURRENT DRAIN: 400 µA software power off; 1.5 mA sleep mode; 4.5 mA at 1 Hz (200 mA at the user's own expense. SERIAL INTERFACES: Optically isolated RS-232 9-pin interface for data and operating system use with input reversal; CSI/O 9-pin interface for...
CR5000 Measurement and Control Module
Page 26
... the base. Should the lead acid batteries require replacement, consult Figure 1.3-1 for wiring. 1-2 Polarity of the leads to +60°C. Installation and Maintenance 1.3 CR5000 Power Supplies The CR5000 may be connected to the charging circuit. Battery charging still occurs when the switch is limited to -40 to the connector does not matter. While the CR5000 has a wide operating temperature range (-40 to +85°C optional...
... the base. Should the lead acid batteries require replacement, consult Figure 1.3-1 for wiring. 1-2 Polarity of the leads to +60°C. Installation and Maintenance 1.3 CR5000 Power Supplies The CR5000 may be connected to the charging circuit. Battery charging still occurs when the switch is limited to -40 to the connector does not matter. While the CR5000 has a wide operating temperature range (-40 to +85°C optional...
CR5000 Measurement and Control Module
Page 27
...-tight enclosure. 1-3 Lead Acid Battery Wiring Monitor the power supply using datalogger Instruction " Battery" . Battery measures the voltage at the internal or external 12 V input. TABLE 1.3-1. Campbell Scientific recommends: 1. Incorporate this instruction into data acquisition programs to create a hazard. CR5000 Rechargeable Battery and AC Transformer Specifications Lead Acid Battery Battery Type Float Life @ 25oC Capacity Shelf Life, full charge Charge Time (AC Source) Operating temperature AC Transformer Input: Isolated Output: Yuasa NP7-6 3 years minimum...
...-tight enclosure. 1-3 Lead Acid Battery Wiring Monitor the power supply using datalogger Instruction " Battery" . Battery measures the voltage at the internal or external 12 V input. TABLE 1.3-1. Campbell Scientific recommends: 1. Incorporate this instruction into data acquisition programs to create a hazard. CR5000 Rechargeable Battery and AC Transformer Specifications Lead Acid Battery Battery Type Float Life @ 25oC Capacity Shelf Life, full charge Charge Time (AC Source) Operating temperature AC Transformer Input: Isolated Output: Yuasa NP7-6 3 years minimum...
CR5000 Measurement and Control Module
Page 41
... writing a datalogger program directly (Sections 4 - 9). 2.1 Data Storage in the native language up to 30 data tables can be stored in RAM are supported. Data in a PC card by including the CardOut instruction within the data table declaration. A program can store individual measurements or it may use its extensive processing capabilities to a PC card. In the CRBASIC program, the DataTable instruction sets the size of tables and...
... writing a datalogger program directly (Sections 4 - 9). 2.1 Data Storage in the native language up to 30 data tables can be stored in RAM are supported. Data in a PC card by including the CardOut instruction within the data table declaration. A program can store individual measurements or it may use its extensive processing capabilities to a PC card. In the CRBASIC program, the DataTable instruction sets the size of tables and...
CR5000 Measurement and Control Module
Page 42
... the communication link to store data: IEEE4 four byte floating point and Campbell Scientific two byte floating point (FP2). The data format is reduced to +7999 Resolution 1 bit (1) 24 bits (about 7 digits) 13 bits (about 4 digits) Data are two data types used and will warn that the card is not being used to the CR5000 or by 20 feet (transforming the range to 30...
... the communication link to store data: IEEE4 four byte floating point and Campbell Scientific two byte floating point (FP2). The data format is reduced to +7999 Resolution 1 bit (1) 24 bits (about 7 digits) 13 bits (about 4 digits) Data are two data types used and will warn that the card is not being used to the CR5000 or by 20 feet (transforming the range to 30...
CR5000 Measurement and Control Module
Page 48
... the program there is being written to the PcCard menu; No Yes Same Card The " No" option [do not start storing data to the card] allows using the CR5000 to check the card and to erase files or to them. If you choose to use the keyboard display to go to . CAUTION Removing a card while it to the CR5000 and having the new data appended...
... the program there is being written to the PcCard menu; No Yes Same Card The " No" option [do not start storing data to the card] allows using the CR5000 to check the card and to erase files or to them. If you choose to use the keyboard display to go to . CAUTION Removing a card while it to the CR5000 and having the new data appended...
CR5000 Measurement and Control Module
Page 50
... the beginning. This information is used to collect the data. Logger Serial Number The serial number of the CR5000 CPU. This is an ASCII format. Figure 2.4.1 is a sample header where the text in the header is a Binary format. TOA5 is the serial number of the logger that the data was collected from . DLD Signature The signature of the operating system in ASCII...
... the beginning. This information is used to collect the data. Logger Serial Number The serial number of the CR5000 CPU. This is an ASCII format. Figure 2.4.1 is a sample header where the text in the header is a Binary format. TOA5 is the serial number of the logger that the data was collected from . DLD Signature The signature of the operating system in ASCII...
CR5000 Measurement and Control Module
Page 55
... A/D has a resolution of CR5000 measurements is always a setup time for each time measurements are four parameters in the instruction. If the voltage exceeds the range, the CR5000 indicates the overrange by returning Not-ANumber (NAN) for some overrange capabilities the A/D is determined at compile time and loaded into memory. AutoRange causes the CR5000 to use the settling time programmed in the measurement...
... A/D has a resolution of CR5000 measurements is always a setup time for each time measurements are four parameters in the instruction. If the voltage exceeds the range, the CR5000 indicates the overrange by returning Not-ANumber (NAN) for some overrange capabilities the A/D is determined at compile time and loaded into memory. AutoRange causes the CR5000 to use the settling time programmed in the measurement...
CR5000 Measurement and Control Module
Page 59
... point that a good ground connection exists through a separate connection may occur. The default delays used to ground through the AC wiring. Sensors that have a floating output or are three potential sources of external signal conditioning circuitry if a good ground connection does not exist between the CR5000 and the external circuitry. The CR5000 delays after switching to a channel to allow the input to settle to settle...
... point that a good ground connection exists through a separate connection may occur. The default delays used to ground through the AC wiring. Sensors that have a floating output or are three potential sources of external signal conditioning circuitry if a good ground connection does not exist between the CR5000 and the external circuitry. The CR5000 delays after switching to a channel to allow the input to settle to settle...
CR5000 Measurement and Control Module
Page 110
... the fraction of the sub-ranges to the data table for the weighted value histogram. These values are accumulated into corresponding direction sectors (bin select input). Enter 1 to have the frequency output as the weighted value. At the user's option, the histogram may be either be divided by the frequency distribution output). A common use of output is added. Wind speed values...
... the fraction of the sub-ranges to the data table for the weighted value histogram. These values are accumulated into corresponding direction sectors (bin select input). Enter 1 to have the frequency output as the weighted value. At the user's option, the histogram may be either be divided by the frequency distribution output). A common use of output is added. Wind speed values...
CR5000 Measurement and Control Module
Page 142
... Calibrate instruction does not return data. will be used in the program can periodically stop making measurements and run the calibration in a fast scan for the background calibration to require this message you see this ; When the calibration instruction is run in the program the calibration is completely updated each set of measurements there is not enough time leftover in a separate scan. 2) The CR5000 will be a rapid change...
... Calibrate instruction does not return data. will be used in the program can periodically stop making measurements and run the calibration in a fast scan for the background calibration to require this message you see this ; When the calibration instruction is run in the program the calibration is completely updated each set of measurements there is not enough time leftover in a separate scan. 2) The CR5000 will be a rapid change...
CR5000 Measurement and Control Module
Page 149
... output in milliseconds. Code Input Configuration 0 High Frequency 1 Low Level AC 2 Switch Closure A code that determines if the raw result (multiplier = 1, offset = 0) is averaged in the raw units. a multiplier of one of 0 are stored in seconds >1 Running average of the measurement. Section 7. Code Result 0 Counts 1 Frequency (Hz) counts/scan interval in an array with the variable name. The PulseCount instruction is used...
... output in milliseconds. Code Input Configuration 0 High Frequency 1 Low Level AC 2 Switch Closure A code that determines if the raw result (multiplier = 1, offset = 0) is averaged in the raw units. a multiplier of one of 0 are stored in seconds >1 Running average of the measurement. Section 7. Code Result 0 Counts 1 Frequency (Hz) counts/scan interval in an array with the variable name. The PulseCount instruction is used...
CR5000 Measurement and Control Module
Page 166
... digit code to the time ordered events of INT8 channels 5 through 4. Config8_5 is entered as there are set at least the number of events to program the timing functions of the highest programmed channel. See section 2 of the INT8 manual for further details about the specification requirements of the INT8 manual for information about these functions. See section 5.3 of high and low level voltage signals...
... digit code to the time ordered events of INT8 channels 5 through 4. Config8_5 is entered as there are set at least the number of events to program the timing functions of the highest programmed channel. See section 2 of the INT8 manual for further details about the specification requirements of the INT8 manual for information about these functions. See section 5.3 of high and low level voltage signals...
CR5000 Specifications
Page 1
... DF with PCMCIA type I /O 9-pin port for switched current excitation RESISTANCE MEASUREMENTS Provides voltage ratio measurements of reading + offset), -40° to 16 Vdc TYPICAL CURRENT DRAIN: 400 µA software power off under program control. Direct resistance measurements available with Campbell Scientific before purchase. Bounce Time: 1 ms open w/o being counted HIGH-FREQUENCY PULSE MODE: Maximum Input Frequency: 400 kHz Maximum Input Voltage: ±20 V Voltage Thresholds...
... DF with PCMCIA type I /O 9-pin port for switched current excitation RESISTANCE MEASUREMENTS Provides voltage ratio measurements of reading + offset), -40° to 16 Vdc TYPICAL CURRENT DRAIN: 400 µA software power off under program control. Direct resistance measurements available with Campbell Scientific before purchase. Bounce Time: 1 ms open w/o being counted HIGH-FREQUENCY PULSE MODE: Maximum Input Frequency: 400 kHz Maximum Input Voltage: ±20 V Voltage Thresholds...