Total Pool ChemistryTM for Aqua RiteTM Pro and Pro Logic® Installation and Operation Manual for AQL-CHEM June 2010 Download and use the latest manual at: www.hayward-pool.com
Model: AQL-CHEM - Page 2

... these models. Refer to sense ORP and pH levels. Probe Cell: The Probe Cell is used with everything needed to allow the Aqua Rite Pro or Pro Logic to the Pro Logic manual for your software revision. Install this relay only if you have one of chlorine and water quality. Description The AQL-CHEM is...
Model: AQL-CHEM - Page 3

... (GFCB) for wiring and installation per local code Before carrying out any other related equipment. A pressure differential is in some installations • Any items that would be required for powering 240VAC dispense pigtail • Extra wire, wire strippers, and wire nuts could be helpful in the plumbing. Installation Overview Installing the AQL-CHEM requires the following steps...
Model: AQL-CHEM - Page 4

... washer Aqua Rite Pro enclosure wall Side Mounting AQL-CHEM to Aqua Rite Pro AQL-CHEM bracket wall Route probe cell cable through the Pro Logic enclosure. After installation, coil excess cable in place. Aqua Rite Pro Side mounting AQL-CHEM to the Aqua Rite Pro: Side mounting the AQL-CHEM will require drilling 3 mounting holes through access hole...
Model: AQL-CHEM - Page 5

... the following steps: Influent Port Effluent Port Sample Stream Port FROM SPA FROM POOL POOL 4 RETURN TO SPA RETURN TO POOL Remote surface mounting the AQL-CHEM: The Probe Cell can be mounted up to the supply and return sides of cable). Use the four mounting holes on the Probe Cell, influent...
Model: AQL-CHEM - Page 6

...pressure fitting to pool water. Using teflon plumber's tape, install the remaining tubing connector and run flex tubing to threads 5 This port can be replaced, use . It's very important that the probes are ...linked polyethylene tubing (PEX). Installing ORP and pH probes to the Probe Cell The ORP and pH probes are allowed to dry out, they will fail and the AQL-CHEM will ensure that the ...
Model: AQL-CHEM - Page 8

...A screw terminal block located inside of the Aqua Rite Pro enclosure is supplied with the AQL-CHEM must be provided by a GFCB (Ground Fault Circuit Breaker). 240VAC pH Dispensing Device ...require a plug-in receptacle, including the Hayward AQL-CHEM2 and AQL-CHEM2240. If your pH dispensing device will connect to the Aqua Rite Pro must be installed and used with pH dispensing devices (...
Model: AQL-CHEM - Page 9

...PS-16 models: Any available Aux or the Lights relay can only be connected to an internal relay. After configuration, the relay's corresponding Aux/Lights output will be used. Installation instructions for this...AQL-CHEM kit must be found packaged with the AQL-CHEM to the Aqua Rite Pro's terminal block as shown in a similar fashion to the diagram on page 9 shows a typical installation of AQL...
Model: AQL-CHEM - Page 10

... N L1 Pigtail 120VAC pH dispense Pigtail (included with AQL-CHEM) use watertight strain relief here 120VAC pH dispense Pigtail (included with AQL-CHEM) to AQL-CHEM2 Pro Logic operating with software version 4.00 or later Pro Logics operating with software version 4.00 or later have built-in support for these Pro Logic units. The diagram below...
Model: AQL-CHEM - Page 11

.... pH Reduction Control Select the desired option related to configure the AQL-CHEM. This mode is helpful when setting up and testing the AQL-CHEM2(-240) or other type of pH level and then automatically ...Rite Pro or Pro Logic to use the AQL-CHEM sensing kit. These wizards are found on the following pages. Detailed information about specific screens relating to the configuration can be ...
Model: AQL-CHEM - Page 13

...error or external problem with the pool and allows the pool owner to which relay prevent is a discrepancy between the two values, the pH Calibration Wizard should be reset in the Pro Logic Installation and Operation manuals...1. Press the "Settings" button. 2. Use "+" and "-" buttons to answer questions when prompted. 5. Hayward suggests that PL-P-4 and PL-PS-4 models will display if ...
Model: AQL-CHEM - Page 14

...AQL-CHEM. This chlorine level is not stabilizing (or does not seem to be stabilizing) there are needed, make adjustments in the Aqua Rite Pro or Pro Logic Operation manuals. After allowing the system to run for 1 week. Adjust salt to recommended levels if using the pH Reduction CTRL set...names Move to next menu item Rotates between Manual On/Off (default), Countdown Timer, Low ...
Model: AQL-CHEM - Page 16

... contamination to this information can be replaced. Pushing the "" buttons will walk the user through the probe cleaning process. If properly cleaned probes continue to the Aqua Rite Pro or Pro Logic. The AQL-CHEM provides instrument grade accuracy which exceeds that changes in small glass or plastic containers with a quality manual test kit.
Model: AQL-CHEM - Page 17

... be capped with probe caps, BNC covers, and other necessary winterizing accessories is winterized, plan to replace any missing items. Contact your local Hayward dealer for more information. 16 Winterizing The AQL-CHEM probes must be drained as part of the normal pool winterizing process. BNC connectors should be protected from freezing conditions. If the...
Model: AQL-CHEM - Page 19

To obtain warranty service or repair, please contact the place of installation. 2. Material supplied or workmanship performed by others in process of purchase or the nearest Hayward/Goldline authorized warranty service center. THESE WARRANTIES GIVE YOU SPECIFIC LEGAL RIGHTS,ANDYOU MAYALSO HAVE OTHER RIGHTS OFEQUIPMENT, LOST PROFITS OR REVENUE, COSTS OF RENTING REPLACEMENTS,AND OTHER ...

Hayward AQL-CHEM Reviews

Do you have an experience with the Hayward AQL-CHEM that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Hayward yet.

Popular Hayward AQL-CHEM Search Terms

The following terms are frequently used to search for Hayward AQL-CHEM support:

Ask a New Question
Use the box below to post a new question about Hayward AQL-CHEM.
Manuals / Documents
Download any of our Hayward AQL-CHEM manuals for free!

We have the following 1 documents available for the Hayward AQL-CHEM:
  • Model: AQL-CHEM

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Hayward Manuals

Find free Hayward AQL-CHEM manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Hayward Reviews

View thousands of Hayward AQL-CHEM user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Hayward customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Hayward customer service rankings, employee comments and much more from our sister site.

Hayward Recalls

Find comprehensive Hayward recall information updated hourly on RecallOwl.com.